流量积算仪说明书

SXL 系列

P MPa 0.10 0.15 0.20 0.25 0.30 0.40 0.50 0.80 1.10 1.40 1.70 2.00 2.50 3.00 3.50 4.00 4.50 5.00 6.00 7.00 8.00 9.00 10.0 12.5 15.0 17.5 20.0 21.5 0.10 0.15 0.20 0.25 0.30 0.40 0.50 0.80 1.10 1.40 1.70 2.00 2.50 3.00 3.50 4.00 4.50 5.00 6.00 7.00 8.00 9.00 10.0 12.5 15.0 17.5 20.0 21.5

流量显示积算仪 / 使用说明书

t℃ 210 0.4507 0.6777 0.9056 1.1349 1.3653 1.8297 2.2997 3.7400 5.2356 6.7913 8.4130 10.0366 12.9776 15.8776 19.3131 22.9129 25.9784 30.0384 37.4508 47.6561 55.5968 70.3863 88.8412 129.5629 170.4577 209.1592 273.4409 320.5455 370 0.3375 0.5066 0.6759 0.8456 1.0156 1.3563 1.6983 2.7305 3.7722 4.8260 5.7779 6.9619 8.7802 10.6308 12.6162 14.4392 16.4018 18.4108 22.5570 29.9035 31.4825 36.3217 41.5274 56.1496 74.5840 100.8176 137.7965 150.0074

SXL 系列

流量显示积算仪 / 使用说明书

附录:过热蒸汽密度表 ( 单位:ρ = K g / m 3 )

150 0.5164 0.7781 1.0423 1.3089 1.5783 2.1237 2.6658 4.3966 6.1313 7.8785 9.8464 11.6295 15.1890 18.4168 22.7008 27.164 30.3852 35.4243 43.8954 56.7201 65.4713 84.5457 108.6250 158.3464 206.4175 250.3934 327.8165 384.6647 310 0.3724 0.5594 0.7465 0.9343 1.1224 1.5000 1.8802 3.0283 4.1943 5.3794 6.5815 7.8061 9.8888 11.9979 14.2565 16.5527 18.9333 21.4221 26.7091 32.5488 39.1399 46.7877 59.6648 81.6034 110.5369 140.3919 182.5462 213.6739 170 0.4925 0.7412 0.9918 1.2444 1.4990 2.0141 2.5380 4.1676 5.8332 7.5163 9.3688 11.0985 14.4516 17.5709 21.5713 25.7470 28.9163 33.6293 41.7475 53.6991 62.1800 79.8261 102.0289 148.7516 194.4276 236.6910 309.9521 363.2975 330 0.3600 0.5404 0.7214 0.9027 1.0844 1.4701 1.8147 2.9215 4.0419 5.1777 6.3309 7.4955 9.4806 11.5143 13.8501 15.749 17.9608 20.2508 25.0502 30.2231 35.8485 42.0680 49.2802 72.0105 98.5531 126.6895 174.3185 192.3164 190 0.4707 0.7079 0.9466 1.1869 1.4287 1.9166 2.4121 3.9372 5.5342 7.1540 9.2473 10.5676 13.7150 16.7243 20.4427 24.3303 27.4475 31.8342 39.5988 50.6780 58.8883 75.1061 95.4346 139.1578 182.4477 222.8603 291.2953 341.9027 350 0.3484 0.5230 0.6980 0.8732 1.0488 1.4010 1.7545 2.8227 3.9030 4.9945 6.0998 7.2186 9.1139 11.0494 13.0286 15.0539 17.1279 19.2627 23.7006 28.4037 33.4179 38.8083 44.7560 62.4178 86.5688 116.3142 166.0907 171.8651 230 0.4323 0.6500 0.8684 1.0849 1.3079 1.7513 2.1992 3.5655 4.9719 6.4288 7.9352 9.5054 12.2406 15.0367 18.2266 21.4954 24.5096 28.2433 35.3020 44.6352 52.3061 65.6665 82.2486 119.9781 158.4766 195.4568 255.5786 299.1880 390 0.3272 0.4912 0.6553 0.8198 0.9845 1.3144 1.6456 2.6440 3.6512 4.6673 5.6936 6.7260 8.4750 10.2493 12.0528 13.8862 15.7527 17.6565 21.5629 25.6330 29.8698 34.3044 39.0006 51.8212 66.8341 85.3228 108.5430 128.1614 250 0.4156 0.6246 0.8342 1.0445 1.2540 1.6527 2.1081 3.4110 4.7459 6.1147 7.5219 8.9744 11.5036 14.1842 17.0530 20.0778 23.0407 26.4483 33.1541 41.6133 49.0145 60.9465 75.6543 110.3842 146.4967 181.6261 236.9217 277.7931 410 0.3176 0.4767 0.6360 0.7955 0.9552 1.2753 1.5961 2.5635 3.5384 4.5220 5.5120 6.5117 8.1938 9.9000 11.6308 13.3077 14.7579 16.9827 20.6900 24.5224 28.4969 32.2947 36.9344 48.5015 61.5530 76.6185 94.4945 106.6360 290 270 0.4001 0.3857 0.6010 0.5795 0.8027 0.7736 1.0048 0.9682 1.2077 1.1634 1.6152 1.5554 2.0255 1.9495 3.2718 3.1453 4.5445 4.3612 5.8437 5.6006 7.1713 6.8607 8.5350 8.1447 10.8794 10.3500 13.3377 12.6359 15.9243 15.0163 18.6603 17.4997 21.5717 20.1028 24.6532 22.8580 31.0062 28.8574 38.5922 35.5704 45.7231 42.4316 56.220 51.5077 65.7699 62.4676 95.7769 91.1964 127.6820 122.5268 163.4280 154.2312 219.0574 201.2031 256.4260 235.0688 450 430 0.3086 0.2998 0.4631 0.4502 0.6178 0.6005 0.7726 0.7507 0.9277 0.8989 1.2377 1.2035 1.5498 1.5060 2.4884 2.4171 3.4335 3.3345 4.3857 4.2575 5.3441 5.1863 6.3090 6.1203 7.9332 7.6898 9.5775 9.2816 11.2425 10.8842 12.9991 12.5087 14.6679 14.1507 16.3719 15.8139 19.9062 19.1981 23.4021 22.6635 27.2913 26.0170 31.1593 29.8733 35.1684 33.6447 45.8023 43.5431 57.5137 54.2497 70.5711 65.9331 85.3276 78.7759 95.1366 87.0939

一、概 述 ..................................... (1) 二、 主要功能特点 .............................. (1) 三、 主要技术指标 .............................. (1) 四、仪表选型 .................................. (2) 五、仪表面板说明 .............................. (3) 六、继电器组态控制 ............................ (4) 七、查看工作、停电时间及实时时钟设置 ........... (5) 八、故障自动补偿 ............................... (6) 九、功能菜单的操作 ............................ (4) 十、通讯寄存器地址 ............................ (8) 十一、仪表端子接线图 .......................... (8) 十二、流量计算公式 ............................ (9) 十 三 、 附 录 .................................. (12) 十四、仪表维修 ............................... (12) 十五、仪表装箱 ............................... (12) 十六、订货须知 ............................... (12)

承蒙关照、支持 我公 司产 品不 胜感 激, 为了你能更好地使用本产品,敬请使用前仔 细阅读本产品使用说明书。如你在使用过程 中对产品存有疑问,请与本公司技术服务部 及业务人员联系。

·1 9 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

SXL 系列

流量显示积算仪 / 使用说明书

一、概 述

本流量表是采用国际上最新数字集成技术和根据国内工业自动控制的实际 需求而研制开发的新一代全智能化仪, 结构严谨、 外型美观, 硬件所采用的元 器件较少, 无电位器等可动器件, 功能齐全, 操作简单, 可靠性、 稳定性高, 适 用于化工、石油、冶金、轻工、食品、电力、能源管理等各个领域。

附录:饱和蒸汽密度表(单位:密度─ρ=Kg/m3;压力─P=MPa; )

0 压力( P ) 密度( ρ ) 压力( P ) 0.1013 0.5977 0.1050 0.1433 0.8265 0.1481 0.1985 1.122 0.2049 0.2701 1.497 0.2783 0.3614 1.967 0.3718 0.4760 2.548 0.4888 0.6181 3.260 0.6339 0.7920 4.123 0.8114 1.0027 5.160 1.0259 1.2551 6.397 1.2829 1.5548 7.864 1.5876 1.9077 9.593 1.9462 2.3198 11.62 2.3645 2.7975 14.00 2.8491 3.3477 16.76 3.4070 0.1127 0.6601 0.1167 0.1583 0.9075 0.1636 0.2182 1.225 0.2250 0.2953 1.627 0.3041 0.3931 2.129 0.4042 0.5155 2.747 0.5292 0.6666 3.502 0.6835 0.8511 4.415 0.8716 1.0737 5.509 1.0983 1.3397 6.812 1.3690 1.6548 8.354 1.6892 2.0248 10.17 2.0650 2.4559 12.30 2.5026 2.9546 14.78 3.0085 3.5279 17.68 3.5897 6 7 压力 P 密度ρ 压力 P 密度ρ 0.1250 0.7277 0.1294 0.7515 0.1746 0.9948 0.1804 1.025 0.2393 1.336 0.2467 1.375 0.3222 1.766 0.3317 1.815 0.4271 2.301 0.4389 2.361 0.5577 2.958 0.5723 3.032 0.7183 3.758 0.7362 3.847 0.9137 4.723 0.9353 4.829 1.1487 5.877 1.1746 6.003 1.4289 7.248 1.4596 7.398 1.7597 8.868 1.7959 9.045 2.1474 10.77 2.1896 10.98 2.5981 13.00 2.6469 13.24 3.1185 15.61 3.1746 15.89 3.7155 18.64 3.7797 18.97 2 1 密度( ρ ) 压力( P ) 0.6180 0.1088 0.8528 0.1532 1.155 0.2114 1.539 0.2867 2.019 0.3823 2.613 0.5021 3.339 0.6502 4.218 0.8310 5.274 1.0496 6.532 1.3111 8.025 1.6210 9.782 1.9852 11.84 2.4098 14.25 2.9010 17.06 3.4670 0.6952 0.1208 0.9359 0.1691 1.261 0.2321 1.672 0.3130 2.185 0.4155 2.816 0.5433 3.586 0.7008 4.515 0.8924 5.629 1.1233 6.955 1.3987 8.522 1.7242 10.37 2.1059 12.53 2.5500 15.05 3.0631 17.99 3.6522 8 压力 P 密度ρ 压力 P 0.1339 0.7758 0.1385 0.1863 1.057 0.1923 0.2543 1.415 0.2621 0.3414 1.864 0.3513 0.4510 2.422 0.4633 0.5872 3.106 0.6025 0.7544 3.937 0.7730 0.9573 4.937 0.9797 1.2010 6.312 1.2278 1.4909 7.551 1.5225 1.8326 9.225 1.8699 2.2323 11.19 2.2757 2.6963 13.49 2.7466 3.2316 16.18 3.2892 3.8448 19.30 3.9107 密度(ρ) 0.6388 0.8798 1.190 1.583 2.073 2.679 3.420 4.316 5.391 6.671 8.188 9.974 12.07 14.52 17.37 0.7105 0.9650 1.298 1.719 2.242 2.886 3.671 4.618 5.752 7.100 8.694 10.57 12.76 15.33 18.31 9 密度ρ 0.8008 1.089 1.455 1.915 2.484 3.182 4.029 5.048 6.264 7.706 9.408 11.41 13.74 16.47 19.64

二、主要功能特点

1 、流量测量、累积准确,清零累积有密码保护。 2、小信号切除比例可自行设定,并且有切除指示。 3、继电器可以任意组态对瞬时流量、程度、压力、脉冲输出累积 流量进行控制。 4 、定量控制用于罐装简单方便,有清零启动键及暂停键,操作方便。 5、 瞬时流量记录输出可设定。 6、 当温度压力测量回路出现故障时, 自动使用键盘设定值补偿。 7、累积脉冲输出。

三、主要技术指标

1、精 度:± 0.5%FS,± 1 个字, 2、信号输入:0 ~10mA,0 ~20mA,4 ~20mA,输入阻抗≤ 250 Ω; 0 ~5 V ,1 ~5V ≥ 5 00 K Ω;标准热电偶(带冷端自动补偿) ; 标准热电阻(线路电阻≤ 1 0 Ω) 。 3 、模拟输出:0 ~1 0 m A (负载 R L ≤ 7 5 0 Ω) ~2 0 m A (负 ,4 载 R L ≤ 5 0 0 Ω) ~5 V ,1 ~5 V ≥ 2 5 0 K Ω。 ;0 4 、报警触点输出:触点容量 2 2 0 V A C / 3 A (阻性负载) 。 5 、配电输出:2 4 V D C ,1 0 0 m A 。 6、供电电源:85 ~26 5VA C,50 HZ 或 24 VD C ± 2V 。 7 、工作环境条件:温度 - 2 0 ~5 0 ℃,相对湿度< 8 5 % R H 。 8 、仪表外形及开孔尺寸(m m ) : 竖式 80 × 160 × 100,开孔尺寸 76 +1 × 152+1, 横式 160 × 80 × 100,开孔尺寸 152+1 × 76 +1, 方形 96 × 96 × 120,开孔尺寸 92 +1 × 92 +1 。 9 、仪表重量:0 . 5 K g 。 ·1 ·

·1 8 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

SXL 系列

流量显示积算仪 / 使用说明书

八、附录

仪表组态时输入信号类型表 输入信号类型 十位数 0 用内补偿电阻

四、仪表选型 (表六)

个位数 0 S 型热电偶 1 R 型热电偶 1 用外补偿电阻 2 B 型热电偶 3 用 Pt100 远端补偿 3 K 型热电偶 4 N 型热电偶 4 用 Cu50 远端补偿 5 E 型热电偶 (本厂用 Cu50 作内补偿电阻, 6 J 型热电偶 如用户需要用外补偿或用Cu50、 7 T 型热电偶 Pt100作远端补偿, 订货时请注明) 8 F1 型热电偶 9 F2 型热电偶 4 Pt100 输入 0 5 Cu50 输入 5 Cu100 输入 0 1 0 1 2 3 4 5 6 7

SXL□□□□□□□□□□□□□□

(表一)

说 明

流量输入

温补输入 压补输入

.T0…...… 无温度补偿.............. XX…… 专用型(固定一种信号输入,见选型分度号类型表) 99………通用型(任意信号输入) P0…...… 无压力补偿 XX…...… 专用型(固定一种信号输入,见选型分度号类型表) 99…..……通用型(任意信号输入) B0 无 B1 ............ 0~10mADC B2 ............ 4~20mADC B3 ............ 0~5VDC B4 ............ 1~5VDC B9 ............ 其 它 ( 订 货 时 请 注 明 ) K0 ... 无 K2 ... 二路继电器输出 K3 ... 定量控制输出 A ....... 220VAC D ....... 24 VDC H .... 横形(160 × 80mm) S .... 竖形(80 × 160mm) F .... 方形(96 × 96mm) p .... 24VDC 外供电 k .... 有开方功能 R .... 带通讯(RS-485 )

热电偶输入

变送 输出

报警输出 工作电源 外 形

辅助功能 (可不选或 多项)

Pt100 输入 Cu50 输入

其它信号输入

6 信号作线性处理

(电压 V 、m V 、 7 信号作开方处理 电流、电阻和频 率 )

0-5V 1-5V 毫伏 mV 电阻 R 频率 F 0-10mA 0-20mA 4-20mA

仪表选型输入信号类型选择表

代码

(表二)

代码 信号类型 Cu50 Cu100 0~5V 1~5V 0~100mV 电阻(R) 频率(F) 0~10mA 0~20mA 4~20mA 测 量 范 围 -50~150℃ -50~150℃ -999~9999 -999~9999 -999~9999 -999~9999 -999~9999 -999~9999 -999~9999 -999~9999

十四、仪表维修

仪表损坏或故障,如属厂方制造质量问题,壹年内厂方免费修 理或更换。

00

信号类型 测 量 范 围 0~1300℃ S

50 51 60 61 62 63 64 65 66 67

01 02 03 1台 1份 1本 04 05 06 07 08 09 40

R B K N E J T F1 F2 Pt100

0~1600℃ 400~1300℃ 0~1300℃ 0~1300℃ 0~900℃ 0~1000℃ 0~1000℃ 0~800℃ 0~800℃ -200~500℃

十五、仪表装箱

SXL-LED 型流量积算仪 产品合格证 产品说明书

十六、订货须知

请按选型表准确提供详细型号 订货 单 位 、地址 、联系 人 、电话 、银行 帐 号 、税号 。 ·1 7 ·

其它 订货请注明输入类型

·2 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

SXL 系列

流量显示积算仪 / 使用说明书

五、仪表面板说明

1、 显示说明

注:1. F 实际流量值 3. P 实际工作表压力(MPa)

2. F。无补偿时流量值 4 . t 实际工作温度(℃)

5. P。设计工作表压力(MPa) 6 . t 。设计工作温度(℃) 7.ρ为介质密度,参数提示符为 Jd--。 (三)线性补偿计算公式 ①不补偿

四位数码显示:瞬时流量或参数提示符。 六位数码显示:累积流量、参数值、压补、温补、实时时间( 分别显 示时分秒及年月日,显示实时间时,小数点闪烁 ) 。

2、 功能键说明 : 设定、前进键;仪表在测量状态下按此键进入参数设置状态,参

数设置完毕,再按此键,进入下一参数设置状态。 :设定状态下,移位键,移动光标,在光标处可以进行参数值修改; 测量状态下,可切换显示累积流量、压力、温度、实时时间。 : 设定状态下,减键,光标位进行数值减;定量控制时,为清零 启动键。 : 设定状态下,加键,光标位进行数值加;定量控制时,为暂停 键 。 :设定状态下,退出键。

②天然气、煤气等气体(温度、压力补偿)

③饱和蒸汽(压力补偿)

④过热蒸气(温度、压力补偿)

3、 指示灯说明

AL:低报警状态指示 T/H:单位指示 AH:高报警状态指示 m3/h:单位指示 SET:设置状态指示 C O M :补偿前流量指示, (按下 键 5 秒)切换到补偿后流量。

注:1. F 实际流量值 2. F 。无补偿时流量值 3. P 实际工作表压力(MPa) 4. t 实际工作温度(℃) 5. P。设计工作表压力(MPa) 6.t。设计工作温度(℃) 7.ρ为介质密度,参数提示符为 Jd--。

·3 ·

·1 6 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

SXL 系列

流量显示积算仪 / 使用说明书

十二、流量计算公式

(一)无补偿计算公式 1 、线性方式: Fo= ρ× 3.6 × f (流量为频率信号时)

六、继电器组态控制

报警类型 P1,P2,P3,P4 说明 千位 百位 十位 个位 0:不报警。 1:越上限报警。 2:越下限报警。 5:越上限报警, C 菜单出现且可修改。 6:越下限报警, C 菜单出现且可修改。 ;———————————————————— 0:报警时,继电器触点闭合。 1:报警时,继电器触点断开。 ;————————————————————(此位无意义,任意值不影响仪表正常运行) ;———————————————————— 0 :报警监控参数为补偿前流量(工况流量) 1:报警监控参数为补偿后流量(标况流量 t=0,p=1 个大气 压) 。 2 :报警监控参数为压力。 3 :报警监控参数为温度。 4 :报警监控参数为累积流量。 8:累积流量脉冲输出,当累积流量>设定值时,继电器动作 1 秒。 9 :流量定量控制,当累积流量

Fo= ρ× Fa × y 2、开方方式:Fo= ρ× Fa × y

注 1 : ① y :流量信号输入百分比 ② F o :显示流量 ③ F a :流量量程 ④ρ:介质密度 ⑤ f :频率

C

⑥ C :频率输入时的流量系数,单位:脉冲数 / 升 (二)开方补偿计算公式 ①液体(温度补偿)

注:公式中压力单位为 MPa,温度单位为℃

·1 5 ·

·4 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

SXL 系列

流量显示积算仪 / 使用说明书

继电器组态举例: 1 、 第一个继电器监控压力值,当压力值>0.8 00 时, 断电器触点 断开。 P 1= 20 11 ,AL1 =0 .8 00 ,F 1= 0. 01 。 2 、 第一个继电器设为流量定量控制,当累积流量 1 . 0 0 0 时, 继电器触点断开。 P 1 = 8 0 1 0 ,AL1 = 1 . 0 0 0 ,F 1 值无意义。 ★★★仪表内用于脉冲输出的累积值为一独立存储区,此累积值不 显示 ,只作 内 部 运 算 。 当累积值大于脉冲输出设定值时,新的累积值 =(累积值)一 (设定值) ,将差值加入累积值中,保证累积输出的精度。设定值必须 大于每秒瞬时流量的 3 倍。 ★★★仪表出厂时继电器的数目是根据用户要求决定,定货时请认 真参阅选型本。累积若需要电压脉冲输出,请在定货时说明 脉冲幅度及极性。 ★★★流量定量控制时,控制设定值(如例 2 中的 3 0 0 . 0 )有如下 限制: D O T S (累积小数位)= 3 :控制设定值为:0 . 0 0 0 ~ 9 . 9 9 9 。 D O T S (累积小数位)= 2 :控制设定值为:0 . 0 0 ~ 9 9 . 9 9 。 D O T S (累积小数位)= 1 :控制设定值为:0 . 0 ~ 9 9 9 . 9 。 D O T S (累积小数位)= 0 :控制设定值为:0 ~ 9 9 9 9 。 ★★★使用温压补偿时,仪表压力值单位为 Mpa,温度单位为℃ 。 ★★★当流量、压力、温度的信号超出显示量程或故障或因设置 不当,补偿后数值超出显示极限时(有效数字 9 9 9 9 )时,相应 的显 示回 路数 字闪 烁。

160X80 主板图

96X96 主板图

注:JP2 拨号开关用作流量回路输入信号选择, 拨号开关用作温补回路输 JP3

入信号选择,JP4 拨号开关用作压补回路输入信号选择,JP1 位用于选择热 电偶温度外补偿和频率输入选择(热电偶信号输入时,将 JP1 第 2 位拨到 ON 位置,频率输入将 JP1 第 1 位拨到 ON 位置)见表五。

(表五)

输 入 信 号 电 流 输 入 电 压 输 入

拔码开关:2 、O N 、1 、3 、O F F 。

拨码开关

说明

拔码开关:1 、3 、O N 、2 、O F F 。 拔码开关:3 、O N 、1 、2 、O F F 。

热电阻输入 热电偶输入 热电偶输入 频率输入 其它信号输入 注:拨码开关 O F F 状态:

拔码开关:2 、O N 、1 、3 、O F F 。 拔码开关:2 、O N 、1 、O F F 。 拔码开关:1 、O N 、2 、O F F 。 拔码开关:1 、O F F 、2 、O F F ,

七、查看开机、停机时间及实时时钟设置

仪表设有 2 个密码,1 . 密码 111 (此密码 B 菜单可修改) ,可 修改仪表运行密码,但不能设置时钟,不能查看开、停机时间, 不能对累积清零。2 . 密码 1 2 3 ,其操作流程如下:

拨码开关 O N 状态; 。

·5 ·

·1 4 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

SXL 系列

长按 SEL 键, (按下 次显示 SEL

流量显示积算仪 / 使用说明书

③输出校准 如如果输出值不准确,应进入输出校准参数选项,调整 dAL1、dAH1、dAL2、 d A H 2 参数,使之符合要求。如果输出值大于相对输出值,按减键减小校准系 数,反之则增大。例如 4~20mA 变送输出,则在仪表相应输出端串连一台万用 表,通过增大或减小校准系数,按 SET 键使输出值对应测量值如不对,再按加键 或减键,返回校准系数项,重复校验。按 Exit 键退出校准,先校准零点,再校 准满度。 注:根据订货要求,个别参数出厂时已被屏蔽。

键 5 秒)出现 PASS 时,输入 123,按 SEL(SEL 键)依

ON-S

;开机时分秒提示符

XXXX .XX

SEL

ON-y

XXXX.XX

;开机年月日提示符

十、通讯方式

1 、通讯协议:通用单片机 A S C I I 、串行口,每路模拟量寄存器占用四个字 节,数据类型;浮点数,起始寄存器 X300~X318,瞬时流量寄存器 X300,总累 计流量寄存器 X318,温度补偿 X304,压力补偿 X308;定量控制时,定量流量累 计寄存器 X316,总累计流量寄存器 X304,以亚控组态王人机界面举例。设备向 导:1、选智能模块,2、单片机,3、通用单片机 ASCII,4、串行口。下步操作 与其它智能表或 PLC 设置相同。如需更详细通讯协议请与我公司联系。

SEL OF-S

;关机时分秒提示符

XXXX .XX

SEL

OF-y XXXX .XX

;关机年月日提示符

十一、仪表端子接线图

SEL

tI-OFF CL-OFF

;时间设置提示符 ;按 ▲ 键显示 ON,再按键进入时钟设置 ;累积清零提示符 键显示 ON,再按键累积清零。 ▲

ON

SEL

ON

;按

;按 E xi t 键退出。

八、故障自动补偿

当使 用温 压 补偿 时 ,温度 、压力 测量 回 路出 现 故障 时 ,仪表 自 动使用键盘设定参数 P KE Y 、T KE Y 的值进行补偿;温度、压力测量 回路恢复正常 后,仪表自动使用 测量值进行 补偿。 ★故 障判 定条 件:热电 偶断 偶、热电 偶信 号线 反 接或 短路 、 P t 1 0 0 开路、C u 5 0 开路、错接信号线或者符合以下条件之一: P-HI

·1 3 ·

·6 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

操 作

SXL 系列

提示符 CB-D 按 SET ××××

流量显示积算仪 / 使用说明书

说 通讯地址 □□□□ 仪表通讯地址:0 ~9 9 9 波特率0:无通讯1:19200 2:9600 3:4800 4: 2400 5:1200 密码设置 原密码设置 明

★当使用温压补偿时,请正确设定压力正常值上限(P - H I ) 及压力正 常值下 限(P - L O ) 温度 正常 值 上限(T - H I )及温 度正 常值 下 限(T - L O ) 。 ★与补偿有关 的参数有: P - O O :孔板 设计 压 力值 ,单位: M p a 。t - O O :孔板 设 计 温 度 值,单位:℃。 P K E Y :故障补偿用压力 值,单位:M p a 。 T K E Y :故障 补 偿用 温 度值 ,单位:℃ 。 P - H I :压力正常值上限,单位:M p a 。 P - L O : 压力正常值下限,单位:M p a 。 t - HI : 温度正常值上限,单位:℃。 t - L O : 温度正常值下限 ,单位:℃。 t P -J: 补偿方式及介质类型。 ★ 参数 t P - J 说明: 千位 百位 十位 个位 出厂时值为1 ; 介质类型 0 :水 1 :天然气、煤气等气体。 2 :饱和蒸气。 3 :过热蒸气。 X :其他值时,默认为过热蒸气。 ; 补偿允许位 0 :不补 偿 ,1 :线性 补 偿 ,2 :开方 补 偿 。 1 :补偿。 X :其他值时,默认为补偿。 ; 压力自动补偿开关 0:压力测量回路故障时,自动采用 PKEY 的值补偿。 1:压力永远采用 PKEY 的值补偿,此时,按 键,下排数 码管可切显参数 P KE Y 的值,P K ××××。 ; 温度自动补偿开关 0:温度测量回路故障时,自动采用 TKE Y 的值补偿。 1:温度永远采用 TKEY 的值补偿此时,按 键,下排数码管 可切显参数 T K E Y 的值,T K ××××。 ;

按 SET

PASS ××××

3 、E 菜单的操作:此菜单是用于校验仪表输入测量精度的一 (表四) 组菜单,校验密码为 521。

操 作 按 SET 健 2秒 按 SET 提示符 PASS ×××× CH-1 AI AU CH-2 BI bRST USTb Ybcd CH-3 CI CU DA DA1L DA1H 说 明

按 SET

按 SET

进入密码选项 将随机设置为 521 按减键或加键改为 O N ,流量信号输入修正 流量电流信号输入修正系数 流量电压信号输入修正系数 按减键或加键改为 O N ,温补信号输入修正 温补电流信号输入修正系数 温补热电阻信号输入修正系数 温补 mv 信号输入修正系数 温补热电偶信号输入零点补偿修正系数 按减键或加键改为 O N ,压补信号输入修正 压补电流信号输入修正系数 压补电压信号输入修正系数

按减键或加键改为 ON,输出修正(不需外加信号)

按 SET

记录输出零点修正系数 记录输出满度修正系数

①补偿系数的校准

在热电偶方式下,按输入类型的补偿方式接线,短接热电偶输入端,应 显示常温值,如果不准,则进入补偿系数校准参数项(K BC D ) ,小于实际温度 则增大参数值,相反减小相应值。然后按设定键常温值,再按减键或加键,返 回校准参数项,重复上述工作,直到准确为止,按设定键进入下个参数。

②输入校准

按按输入类型,输入一定值(如量程上限值) ,如果不准确,就调整相应 的参数,使之符合要求。如果显示值大于设定量程值,按减键减小校准系数, 反之则增大。例如 4~20mA 控制输入,则在仪表相应输入端加入 20mA 信号,通 过增大或减小校准系数,按 SET 键使显示值为输入量程上限设定值如不对,再按 加键或减键,返回校准系数项,重复校验。同时按 S E T 键和减键退出校准。 零点 不用 校验 。

·7 ·

·1 2 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

操 作 按 SET 提示符 P1 ××××

流量显示积算仪 / 使用说明书

说 报警类型设定 □□□□显示面板

0 不报警 1 越上限报警(C 菜单不可看) 2 越下限报警(C 菜单不可看) 5 越上限报警(C 菜单可修改) 6 越下限报警(C 菜单可修改) 0 继电器触点闭合报警 1 继电器触点断开报警 0 报警时闪烁 1 报警时不闪烁 报警参数,见第四页。

SXL 系列

流量显示积算仪 / 使用说明书

按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET

AL1 ×× F1 ×× P2 ×××× AL2 ×××× F2 ×××× P3 ×××× AL3 ×××× F3 ×××× P4 ×××× AL4 ×××× F4(T) ×××× DAT ×××× DAH ×× DAL ×× tydA ××××

报警 值设 定(定 量控 制时 ,定量 值设 定) 工程量 报警回差 工程量,偏差值(定量控制时,此值无效) 报警类型设定: (与 P 1 含义相同

★★★ 仪表 开机 流量: 通电 —à 数码管全亮(测试数码管)—à 软件版本号 —à 瞬时流量 流量信号输入类型 累积流量 ★★★累积流量累积时间:每秒累积 1 次。 ★★★仪表运行时下排数码管按移位键时切换显示内容如下: 累积流量 à 压力通道值或键盘设定值(参数 P K ……)à 温度通 道值或键盘设定值(参数 T K ……)à 实时时间时、分、秒 à 实时 时间年、月、日;显示实时时间时,小数点闪烁。 ★★★仪表运行状态下,长按加键(按住加键 5 秒)时切换显示补偿前 流量及补偿后流量,当面板上的 COM 灯亮时,当前显示的流量为补偿前 流量(小信号切除) 。 ;———————————————————————————— ★★★ 仪表 故障 提示:

字符 BCLO BCHI OULO OUHI ntyP ItPO NSQR 意义 补偿温度< 0℃ 补偿温度> 50℃ 输入信号过低 输入信号过高 选择类型无效 系数溢出 负数开方 累积不保存 信号输入过高,频率信号过大,小数点位置不对 或信号太大或校正参数混乱,需初始化。 负数开方 表内电池需要更换 环境温度< 0℃ 补偿电阻未接好,补偿参数不对,类型选错或 环境温度> 50℃ 热电偶断偶,pt 10 0,c u5 0 接错或输入信号不对 或输入信号过低或校正系数过小。 校正系数过大或输入信号接法不对或输入信号 过高,热电偶断偶,p t 1 0 0 , c u 5 0 开路。 备注 补偿电阻未接好,补偿参数不对,类型选错或

报警值设定 工 程 量 (定 量 控 制时 ,定量 报 警 值) 报警回差 工程量,偏差值 报警类型设定 (与 P 1 含义相同) 报警值设定 工程量 报警回差 工程量,偏差值 报警类型设定 (与 P 1 含义相同) 报警值设定 工程量 报警回 差 (定量控制时,间隔时间值设定)

工程 量,偏差 值 变送输出参数选择

个位 0 : 补偿前流量;1 : 补偿后流量;2 : 压力;3 : 温度

参数小数位更改说明: 如下参数按 位改变,再按 移位键使小数点闪烁,按 移位键使小数点不闪烁,最后按 键或 键可使小数 键保存:

变送输出量程上限 变送输出量程下限 变送输出类型选择 个位0:0~10mA; 1:4~20mA; 2:1~5V

C(流量系数) 、AL1(第一个继电器报警设定值) 、F1(第一个继 电器报警回差) 、AL2、F2、AL3、F3、AL4、F4、H-F、L-F、JD--。 H-P、L-P、PKEY、POO、P-HI、P-LO 的小数位为 DOTP 的值。 H-T、L-T、TKEY、TOO、T-HI、T-LO 的小数位为 DOTT 的值。 ;————————————————————————————

·1 1 ·

·8 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

操 作 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET

SXL 系列

提示符

流量显示积算仪 / 使用说明书

(续表三) 九、功能菜单的操作

1 、C 菜单的操作:此菜单无密码,是操作工使用的菜单, 主要查看、修改 A L 1 、A L 2 、A L 3 、A L 4 参数。按 Q 键返回测量状 态 。

操 作 按S 键 按S 键 按S 键 按S 键 显示内容

AL1 XXXX AL2 XXXX AL3 XXXX AL4 XXXX

(表二)

含义及操作

在仪表测量状态下,按 S E T 键进入 C 的权限查看或修改 A L 1 参数。 在仪表测量状态下,按 S E T 键进入 C 的权限查看或修改 A L 2 参数。 在仪表测量状态下,按 S E T 键进入 C 的权限查看或修改 A L 3 参数。 在仪表测量状态下,按 S E T 键进入 C 的权限查看或修改 A L 4 参数。 菜单,根据 B 菜单 菜单,根据 B 菜单 菜单,根据 B 菜单 菜单,根据 B 菜单

压补输入信号类型 IN-P ×××× 二位代码(见附录仪表组态输入信号类型表) 压补显示小数点位数设定 DOTP 工程量 ×× 压补显示量程上限设定 H-P 工程量 ×× 压补显示量程下限设定 L-P 工程量 ×××× 流量累积小数点位数设定 DOTS ×××× 工程量 0 ~ 0 . 9 9 9 , 数值越大,抗干扰能力越强。个位为0,个位为0 , m3 / FILT ×××× h 单位灯亮、个位为1 , t / h 单位灯亮 、个位为2 , K g / h 单位灯亮 介质补偿 TP-J □□□□ ××× 0 不补偿,1 线性补偿 2 开方补偿

介质类型:0 水,1 气体,2 饱和蒸汽,3 过热蒸汽

2、B 菜单的操作:此菜单是仪表专业技术人员定义及选择仪表各 项功能的运行和控制方式的一组菜单。 B菜单包含C菜单中的所有选项, 并且定义 C 菜单中的选项是否可修改。按 Q 键退出设置。

1温度用健盘设定值(TKEY)补偿,tp-J 参数说明见第7 页 1 压力用健盘设定值(P K E Y )补偿

(表三)

按 SET 按 SET 按 SET 按 SET 按 SET

操 作 按 SET

提示符 PASS ×××× IN-F ×× DOTF ×× H-F ×××× L-F ×××× IN-T ×××× DOTT ×××× H-T ×××× L-T ××××

进入密码 随机数,设置为 1 1 1 ,P A S S 参数正确,进入 B 菜单 流量输入信号类型 二位代码(见附录仪表组态输入类型表)表八 瞬时流量显示小数点位数设定 (设定小数点时移位后, 按 移位键小数点不闪烁再按设定方可,是则出现乱码。 流量量程上限设定 工程量,小数点可移动 流量量程下限设定 工程量,小数点可移动 温补输入信号类型 二位代码(见附录仪表组态输入信号类型表) 温补显示小数点位数设定 工程量 温补显示量程上限设定 工程量 温补显示量程下限设定 工程量

按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET

按 SET 按 SET 按 SET

按 SET 按 SET 按 SET 按 SET

测量介质密度,单位 Kg/m 3 , JD-。 ×××× 小数点可移动(出厂值 1000) 设计 额定 温度 。 T-00 , ×××× 工 程 量 ( 孔 板 设 计 温 度 ) 单 位 ℃ 设计 额定 压力 。 P-00 ,单位 M P a 。 ×××× 工程量(孔板设计压力) 小流量切除,三位小数点 FL00 ×××× 工程量(如:3 0 % 设为 0 . 3 0 0 ) 键盘设定补偿温度值 TKEY ×××× 工程量,单位℃, 键盘设定补偿压力值 PKEY ×××× 工程量单位 MPa。 温度正常值上限,工程量,单位℃ T-HI (实测温度值大于此值时用 TKEY 的值进行补偿) ×××× 温度正常值下限,工程量,单位℃ T-LO (实测温度值小于此值时用 TKEY 的值进行补偿) ×××× 压力正常值上限,工程量,单位 MPa。 P-HI (实测压力值大于此值时用 PKEY 的值进行补偿) ×××× 压力正常值下限,工程量,单位 MPa。 P-LO (实测压力值小于此值时用 PKEY 的值进行补偿) ×××× 涡街截止频率 J-FH ×××× 工程量: C 涡街流量系数( 单位:脉冲数 / 1 0 0 升) ×××× 工 程 量 :

·9 · ·1 0 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

智能流量积算仪使用说明

SXL 系列

P MPa 0.10 0.15 0.20 0.25 0.30 0.40 0.50 0.80 1.10 1.40 1.70 2.00 2.50 3.00 3.50 4.00 4.50 5.00 6.00 7.00 8.00 9.00 10.0 12.5 15.0 17.5 20.0 21.5 0.10 0.15 0.20 0.25 0.30 0.40 0.50 0.80 1.10 1.40 1.70 2.00 2.50 3.00 3.50 4.00 4.50 5.00 6.00 7.00 8.00 9.00 10.0 12.5 15.0 17.5 20.0 21.5

流量显示积算仪 / 使用说明书

t℃ 210 0.4507 0.6777 0.9056 1.1349 1.3653 1.8297 2.2997 3.7400 5.2356 6.7913 8.4130 10.0366 12.9776 15.8776 19.3131 22.9129 25.9784 30.0384 37.4508 47.6561 55.5968 70.3863 88.8412 129.5629 170.4577 209.1592 273.4409 320.5455 370 0.3375 0.5066 0.6759 0.8456 1.0156 1.3563 1.6983 2.7305 3.7722 4.8260 5.7779 6.9619 8.7802 10.6308 12.6162 14.4392 16.4018 18.4108 22.5570 29.9035 31.4825 36.3217 41.5274 56.1496 74.5840 100.8176 137.7965 150.0074

SXL 系列

流量显示积算仪 / 使用说明书

附录:过热蒸汽密度表 ( 单位:ρ = K g / m 3 )

150 0.5164 0.7781 1.0423 1.3089 1.5783 2.1237 2.6658 4.3966 6.1313 7.8785 9.8464 11.6295 15.1890 18.4168 22.7008 27.164 30.3852 35.4243 43.8954 56.7201 65.4713 84.5457 108.6250 158.3464 206.4175 250.3934 327.8165 384.6647 310 0.3724 0.5594 0.7465 0.9343 1.1224 1.5000 1.8802 3.0283 4.1943 5.3794 6.5815 7.8061 9.8888 11.9979 14.2565 16.5527 18.9333 21.4221 26.7091 32.5488 39.1399 46.7877 59.6648 81.6034 110.5369 140.3919 182.5462 213.6739 170 0.4925 0.7412 0.9918 1.2444 1.4990 2.0141 2.5380 4.1676 5.8332 7.5163 9.3688 11.0985 14.4516 17.5709 21.5713 25.7470 28.9163 33.6293 41.7475 53.6991 62.1800 79.8261 102.0289 148.7516 194.4276 236.6910 309.9521 363.2975 330 0.3600 0.5404 0.7214 0.9027 1.0844 1.4701 1.8147 2.9215 4.0419 5.1777 6.3309 7.4955 9.4806 11.5143 13.8501 15.749 17.9608 20.2508 25.0502 30.2231 35.8485 42.0680 49.2802 72.0105 98.5531 126.6895 174.3185 192.3164 190 0.4707 0.7079 0.9466 1.1869 1.4287 1.9166 2.4121 3.9372 5.5342 7.1540 9.2473 10.5676 13.7150 16.7243 20.4427 24.3303 27.4475 31.8342 39.5988 50.6780 58.8883 75.1061 95.4346 139.1578 182.4477 222.8603 291.2953 341.9027 350 0.3484 0.5230 0.6980 0.8732 1.0488 1.4010 1.7545 2.8227 3.9030 4.9945 6.0998 7.2186 9.1139 11.0494 13.0286 15.0539 17.1279 19.2627 23.7006 28.4037 33.4179 38.8083 44.7560 62.4178 86.5688 116.3142 166.0907 171.8651 230 0.4323 0.6500 0.8684 1.0849 1.3079 1.7513 2.1992 3.5655 4.9719 6.4288 7.9352 9.5054 12.2406 15.0367 18.2266 21.4954 24.5096 28.2433 35.3020 44.6352 52.3061 65.6665 82.2486 119.9781 158.4766 195.4568 255.5786 299.1880 390 0.3272 0.4912 0.6553 0.8198 0.9845 1.3144 1.6456 2.6440 3.6512 4.6673 5.6936 6.7260 8.4750 10.2493 12.0528 13.8862 15.7527 17.6565 21.5629 25.6330 29.8698 34.3044 39.0006 51.8212 66.8341 85.3228 108.5430 128.1614 250 0.4156 0.6246 0.8342 1.0445 1.2540 1.6527 2.1081 3.4110 4.7459 6.1147 7.5219 8.9744 11.5036 14.1842 17.0530 20.0778 23.0407 26.4483 33.1541 41.6133 49.0145 60.9465 75.6543 110.3842 146.4967 181.6261 236.9217 277.7931 410 0.3176 0.4767 0.6360 0.7955 0.9552 1.2753 1.5961 2.5635 3.5384 4.5220 5.5120 6.5117 8.1938 9.9000 11.6308 13.3077 14.7579 16.9827 20.6900 24.5224 28.4969 32.2947 36.9344 48.5015 61.5530 76.6185 94.4945 106.6360 290 270 0.4001 0.3857 0.6010 0.5795 0.8027 0.7736 1.0048 0.9682 1.2077 1.1634 1.6152 1.5554 2.0255 1.9495 3.2718 3.1453 4.5445 4.3612 5.8437 5.6006 7.1713 6.8607 8.5350 8.1447 10.8794 10.3500 13.3377 12.6359 15.9243 15.0163 18.6603 17.4997 21.5717 20.1028 24.6532 22.8580 31.0062 28.8574 38.5922 35.5704 45.7231 42.4316 56.220 51.5077 65.7699 62.4676 95.7769 91.1964 127.6820 122.5268 163.4280 154.2312 219.0574 201.2031 256.4260 235.0688 450 430 0.3086 0.2998 0.4631 0.4502 0.6178 0.6005 0.7726 0.7507 0.9277 0.8989 1.2377 1.2035 1.5498 1.5060 2.4884 2.4171 3.4335 3.3345 4.3857 4.2575 5.3441 5.1863 6.3090 6.1203 7.9332 7.6898 9.5775 9.2816 11.2425 10.8842 12.9991 12.5087 14.6679 14.1507 16.3719 15.8139 19.9062 19.1981 23.4021 22.6635 27.2913 26.0170 31.1593 29.8733 35.1684 33.6447 45.8023 43.5431 57.5137 54.2497 70.5711 65.9331 85.3276 78.7759 95.1366 87.0939

一、概 述 ..................................... (1) 二、 主要功能特点 .............................. (1) 三、 主要技术指标 .............................. (1) 四、仪表选型 .................................. (2) 五、仪表面板说明 .............................. (3) 六、继电器组态控制 ............................ (4) 七、查看工作、停电时间及实时时钟设置 ........... (5) 八、故障自动补偿 ............................... (6) 九、功能菜单的操作 ............................ (4) 十、通讯寄存器地址 ............................ (8) 十一、仪表端子接线图 .......................... (8) 十二、流量计算公式 ............................ (9) 十 三 、 附 录 .................................. (12) 十四、仪表维修 ............................... (12) 十五、仪表装箱 ............................... (12) 十六、订货须知 ............................... (12)

承蒙关照、支持 我公 司产 品不 胜感 激, 为了你能更好地使用本产品,敬请使用前仔 细阅读本产品使用说明书。如你在使用过程 中对产品存有疑问,请与本公司技术服务部 及业务人员联系。

·1 9 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

SXL 系列

流量显示积算仪 / 使用说明书

一、概 述

本流量表是采用国际上最新数字集成技术和根据国内工业自动控制的实际 需求而研制开发的新一代全智能化仪, 结构严谨、 外型美观, 硬件所采用的元 器件较少, 无电位器等可动器件, 功能齐全, 操作简单, 可靠性、 稳定性高, 适 用于化工、石油、冶金、轻工、食品、电力、能源管理等各个领域。

附录:饱和蒸汽密度表(单位:密度─ρ=Kg/m3;压力─P=MPa; )

0 压力( P ) 密度( ρ ) 压力( P ) 0.1013 0.5977 0.1050 0.1433 0.8265 0.1481 0.1985 1.122 0.2049 0.2701 1.497 0.2783 0.3614 1.967 0.3718 0.4760 2.548 0.4888 0.6181 3.260 0.6339 0.7920 4.123 0.8114 1.0027 5.160 1.0259 1.2551 6.397 1.2829 1.5548 7.864 1.5876 1.9077 9.593 1.9462 2.3198 11.62 2.3645 2.7975 14.00 2.8491 3.3477 16.76 3.4070 0.1127 0.6601 0.1167 0.1583 0.9075 0.1636 0.2182 1.225 0.2250 0.2953 1.627 0.3041 0.3931 2.129 0.4042 0.5155 2.747 0.5292 0.6666 3.502 0.6835 0.8511 4.415 0.8716 1.0737 5.509 1.0983 1.3397 6.812 1.3690 1.6548 8.354 1.6892 2.0248 10.17 2.0650 2.4559 12.30 2.5026 2.9546 14.78 3.0085 3.5279 17.68 3.5897 6 7 压力 P 密度ρ 压力 P 密度ρ 0.1250 0.7277 0.1294 0.7515 0.1746 0.9948 0.1804 1.025 0.2393 1.336 0.2467 1.375 0.3222 1.766 0.3317 1.815 0.4271 2.301 0.4389 2.361 0.5577 2.958 0.5723 3.032 0.7183 3.758 0.7362 3.847 0.9137 4.723 0.9353 4.829 1.1487 5.877 1.1746 6.003 1.4289 7.248 1.4596 7.398 1.7597 8.868 1.7959 9.045 2.1474 10.77 2.1896 10.98 2.5981 13.00 2.6469 13.24 3.1185 15.61 3.1746 15.89 3.7155 18.64 3.7797 18.97 2 1 密度( ρ ) 压力( P ) 0.6180 0.1088 0.8528 0.1532 1.155 0.2114 1.539 0.2867 2.019 0.3823 2.613 0.5021 3.339 0.6502 4.218 0.8310 5.274 1.0496 6.532 1.3111 8.025 1.6210 9.782 1.9852 11.84 2.4098 14.25 2.9010 17.06 3.4670 0.6952 0.1208 0.9359 0.1691 1.261 0.2321 1.672 0.3130 2.185 0.4155 2.816 0.5433 3.586 0.7008 4.515 0.8924 5.629 1.1233 6.955 1.3987 8.522 1.7242 10.37 2.1059 12.53 2.5500 15.05 3.0631 17.99 3.6522 8 压力 P 密度ρ 压力 P 0.1339 0.7758 0.1385 0.1863 1.057 0.1923 0.2543 1.415 0.2621 0.3414 1.864 0.3513 0.4510 2.422 0.4633 0.5872 3.106 0.6025 0.7544 3.937 0.7730 0.9573 4.937 0.9797 1.2010 6.312 1.2278 1.4909 7.551 1.5225 1.8326 9.225 1.8699 2.2323 11.19 2.2757 2.6963 13.49 2.7466 3.2316 16.18 3.2892 3.8448 19.30 3.9107 密度(ρ) 0.6388 0.8798 1.190 1.583 2.073 2.679 3.420 4.316 5.391 6.671 8.188 9.974 12.07 14.52 17.37 0.7105 0.9650 1.298 1.719 2.242 2.886 3.671 4.618 5.752 7.100 8.694 10.57 12.76 15.33 18.31 9 密度ρ 0.8008 1.089 1.455 1.915 2.484 3.182 4.029 5.048 6.264 7.706 9.408 11.41 13.74 16.47 19.64

二、主要功能特点

1 、流量测量、累积准确,清零累积有密码保护。 2、小信号切除比例可自行设定,并且有切除指示。 3、继电器可以任意组态对瞬时流量、程度、压力、脉冲输出累积 流量进行控制。 4 、定量控制用于罐装简单方便,有清零启动键及暂停键,操作方便。 5、 瞬时流量记录输出可设定。 6、 当温度压力测量回路出现故障时, 自动使用键盘设定值补偿。 7、累积脉冲输出。

三、主要技术指标

1、精 度:± 0.5%FS,± 1 个字, 2、信号输入:0 ~10mA,0 ~20mA,4 ~20mA,输入阻抗≤ 250 Ω; 0 ~5 V ,1 ~5V ≥ 5 00 K Ω;标准热电偶(带冷端自动补偿) ; 标准热电阻(线路电阻≤ 1 0 Ω) 。 3 、模拟输出:0 ~1 0 m A (负载 R L ≤ 7 5 0 Ω) ~2 0 m A (负 ,4 载 R L ≤ 5 0 0 Ω) ~5 V ,1 ~5 V ≥ 2 5 0 K Ω。 ;0 4 、报警触点输出:触点容量 2 2 0 V A C / 3 A (阻性负载) 。 5 、配电输出:2 4 V D C ,1 0 0 m A 。 6、供电电源:85 ~26 5VA C,50 HZ 或 24 VD C ± 2V 。 7 、工作环境条件:温度 - 2 0 ~5 0 ℃,相对湿度< 8 5 % R H 。 8 、仪表外形及开孔尺寸(m m ) : 竖式 80 × 160 × 100,开孔尺寸 76 +1 × 152+1, 横式 160 × 80 × 100,开孔尺寸 152+1 × 76 +1, 方形 96 × 96 × 120,开孔尺寸 92 +1 × 92 +1 。 9 、仪表重量:0 . 5 K g 。 ·1 ·

·1 8 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

SXL 系列

流量显示积算仪 / 使用说明书

八、附录

仪表组态时输入信号类型表 输入信号类型 十位数 0 用内补偿电阻

四、仪表选型 (表六)

个位数 0 S 型热电偶 1 R 型热电偶 1 用外补偿电阻 2 B 型热电偶 3 用 Pt100 远端补偿 3 K 型热电偶 4 N 型热电偶 4 用 Cu50 远端补偿 5 E 型热电偶 (本厂用 Cu50 作内补偿电阻, 6 J 型热电偶 如用户需要用外补偿或用Cu50、 7 T 型热电偶 Pt100作远端补偿, 订货时请注明) 8 F1 型热电偶 9 F2 型热电偶 4 Pt100 输入 0 5 Cu50 输入 5 Cu100 输入 0 1 0 1 2 3 4 5 6 7

SXL□□□□□□□□□□□□□□

(表一)

说 明

流量输入

温补输入 压补输入

.T0…...… 无温度补偿.............. XX…… 专用型(固定一种信号输入,见选型分度号类型表) 99………通用型(任意信号输入) P0…...… 无压力补偿 XX…...… 专用型(固定一种信号输入,见选型分度号类型表) 99…..……通用型(任意信号输入) B0 无 B1 ............ 0~10mADC B2 ............ 4~20mADC B3 ............ 0~5VDC B4 ............ 1~5VDC B9 ............ 其 它 ( 订 货 时 请 注 明 ) K0 ... 无 K2 ... 二路继电器输出 K3 ... 定量控制输出 A ....... 220VAC D ....... 24 VDC H .... 横形(160 × 80mm) S .... 竖形(80 × 160mm) F .... 方形(96 × 96mm) p .... 24VDC 外供电 k .... 有开方功能 R .... 带通讯(RS-485 )

热电偶输入

变送 输出

报警输出 工作电源 外 形

辅助功能 (可不选或 多项)

Pt100 输入 Cu50 输入

其它信号输入

6 信号作线性处理

(电压 V 、m V 、 7 信号作开方处理 电流、电阻和频 率 )

0-5V 1-5V 毫伏 mV 电阻 R 频率 F 0-10mA 0-20mA 4-20mA

仪表选型输入信号类型选择表

代码

(表二)

代码 信号类型 Cu50 Cu100 0~5V 1~5V 0~100mV 电阻(R) 频率(F) 0~10mA 0~20mA 4~20mA 测 量 范 围 -50~150℃ -50~150℃ -999~9999 -999~9999 -999~9999 -999~9999 -999~9999 -999~9999 -999~9999 -999~9999

十四、仪表维修

仪表损坏或故障,如属厂方制造质量问题,壹年内厂方免费修 理或更换。

00

信号类型 测 量 范 围 0~1300℃ S

50 51 60 61 62 63 64 65 66 67

01 02 03 1台 1份 1本 04 05 06 07 08 09 40

R B K N E J T F1 F2 Pt100

0~1600℃ 400~1300℃ 0~1300℃ 0~1300℃ 0~900℃ 0~1000℃ 0~1000℃ 0~800℃ 0~800℃ -200~500℃

十五、仪表装箱

SXL-LED 型流量积算仪 产品合格证 产品说明书

十六、订货须知

请按选型表准确提供详细型号 订货 单 位 、地址 、联系 人 、电话 、银行 帐 号 、税号 。 ·1 7 ·

其它 订货请注明输入类型

·2 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

SXL 系列

流量显示积算仪 / 使用说明书

五、仪表面板说明

1、 显示说明

注:1. F 实际流量值 3. P 实际工作表压力(MPa)

2. F。无补偿时流量值 4 . t 实际工作温度(℃)

5. P。设计工作表压力(MPa) 6 . t 。设计工作温度(℃) 7.ρ为介质密度,参数提示符为 Jd--。 (三)线性补偿计算公式 ①不补偿

四位数码显示:瞬时流量或参数提示符。 六位数码显示:累积流量、参数值、压补、温补、实时时间( 分别显 示时分秒及年月日,显示实时间时,小数点闪烁 ) 。

2、 功能键说明 : 设定、前进键;仪表在测量状态下按此键进入参数设置状态,参

数设置完毕,再按此键,进入下一参数设置状态。 :设定状态下,移位键,移动光标,在光标处可以进行参数值修改; 测量状态下,可切换显示累积流量、压力、温度、实时时间。 : 设定状态下,减键,光标位进行数值减;定量控制时,为清零 启动键。 : 设定状态下,加键,光标位进行数值加;定量控制时,为暂停 键 。 :设定状态下,退出键。

②天然气、煤气等气体(温度、压力补偿)

③饱和蒸汽(压力补偿)

④过热蒸气(温度、压力补偿)

3、 指示灯说明

AL:低报警状态指示 T/H:单位指示 AH:高报警状态指示 m3/h:单位指示 SET:设置状态指示 C O M :补偿前流量指示, (按下 键 5 秒)切换到补偿后流量。

注:1. F 实际流量值 2. F 。无补偿时流量值 3. P 实际工作表压力(MPa) 4. t 实际工作温度(℃) 5. P。设计工作表压力(MPa) 6.t。设计工作温度(℃) 7.ρ为介质密度,参数提示符为 Jd--。

·3 ·

·1 6 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

SXL 系列

流量显示积算仪 / 使用说明书

十二、流量计算公式

(一)无补偿计算公式 1 、线性方式: Fo= ρ× 3.6 × f (流量为频率信号时)

六、继电器组态控制

报警类型 P1,P2,P3,P4 说明 千位 百位 十位 个位 0:不报警。 1:越上限报警。 2:越下限报警。 5:越上限报警, C 菜单出现且可修改。 6:越下限报警, C 菜单出现且可修改。 ;———————————————————— 0:报警时,继电器触点闭合。 1:报警时,继电器触点断开。 ;————————————————————(此位无意义,任意值不影响仪表正常运行) ;———————————————————— 0 :报警监控参数为补偿前流量(工况流量) 1:报警监控参数为补偿后流量(标况流量 t=0,p=1 个大气 压) 。 2 :报警监控参数为压力。 3 :报警监控参数为温度。 4 :报警监控参数为累积流量。 8:累积流量脉冲输出,当累积流量>设定值时,继电器动作 1 秒。 9 :流量定量控制,当累积流量

Fo= ρ× Fa × y 2、开方方式:Fo= ρ× Fa × y

注 1 : ① y :流量信号输入百分比 ② F o :显示流量 ③ F a :流量量程 ④ρ:介质密度 ⑤ f :频率

C

⑥ C :频率输入时的流量系数,单位:脉冲数 / 升 (二)开方补偿计算公式 ①液体(温度补偿)

注:公式中压力单位为 MPa,温度单位为℃

·1 5 ·

·4 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

SXL 系列

流量显示积算仪 / 使用说明书

继电器组态举例: 1 、 第一个继电器监控压力值,当压力值>0.8 00 时, 断电器触点 断开。 P 1= 20 11 ,AL1 =0 .8 00 ,F 1= 0. 01 。 2 、 第一个继电器设为流量定量控制,当累积流量 1 . 0 0 0 时, 继电器触点断开。 P 1 = 8 0 1 0 ,AL1 = 1 . 0 0 0 ,F 1 值无意义。 ★★★仪表内用于脉冲输出的累积值为一独立存储区,此累积值不 显示 ,只作 内 部 运 算 。 当累积值大于脉冲输出设定值时,新的累积值 =(累积值)一 (设定值) ,将差值加入累积值中,保证累积输出的精度。设定值必须 大于每秒瞬时流量的 3 倍。 ★★★仪表出厂时继电器的数目是根据用户要求决定,定货时请认 真参阅选型本。累积若需要电压脉冲输出,请在定货时说明 脉冲幅度及极性。 ★★★流量定量控制时,控制设定值(如例 2 中的 3 0 0 . 0 )有如下 限制: D O T S (累积小数位)= 3 :控制设定值为:0 . 0 0 0 ~ 9 . 9 9 9 。 D O T S (累积小数位)= 2 :控制设定值为:0 . 0 0 ~ 9 9 . 9 9 。 D O T S (累积小数位)= 1 :控制设定值为:0 . 0 ~ 9 9 9 . 9 。 D O T S (累积小数位)= 0 :控制设定值为:0 ~ 9 9 9 9 。 ★★★使用温压补偿时,仪表压力值单位为 Mpa,温度单位为℃ 。 ★★★当流量、压力、温度的信号超出显示量程或故障或因设置 不当,补偿后数值超出显示极限时(有效数字 9 9 9 9 )时,相应 的显 示回 路数 字闪 烁。

160X80 主板图

96X96 主板图

注:JP2 拨号开关用作流量回路输入信号选择, 拨号开关用作温补回路输 JP3

入信号选择,JP4 拨号开关用作压补回路输入信号选择,JP1 位用于选择热 电偶温度外补偿和频率输入选择(热电偶信号输入时,将 JP1 第 2 位拨到 ON 位置,频率输入将 JP1 第 1 位拨到 ON 位置)见表五。

(表五)

输 入 信 号 电 流 输 入 电 压 输 入

拔码开关:2 、O N 、1 、3 、O F F 。

拨码开关

说明

拔码开关:1 、3 、O N 、2 、O F F 。 拔码开关:3 、O N 、1 、2 、O F F 。

热电阻输入 热电偶输入 热电偶输入 频率输入 其它信号输入 注:拨码开关 O F F 状态:

拔码开关:2 、O N 、1 、3 、O F F 。 拔码开关:2 、O N 、1 、O F F 。 拔码开关:1 、O N 、2 、O F F 。 拔码开关:1 、O F F 、2 、O F F ,

七、查看开机、停机时间及实时时钟设置

仪表设有 2 个密码,1 . 密码 111 (此密码 B 菜单可修改) ,可 修改仪表运行密码,但不能设置时钟,不能查看开、停机时间, 不能对累积清零。2 . 密码 1 2 3 ,其操作流程如下:

拨码开关 O N 状态; 。

·5 ·

·1 4 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

SXL 系列

长按 SEL 键, (按下 次显示 SEL

流量显示积算仪 / 使用说明书

③输出校准 如如果输出值不准确,应进入输出校准参数选项,调整 dAL1、dAH1、dAL2、 d A H 2 参数,使之符合要求。如果输出值大于相对输出值,按减键减小校准系 数,反之则增大。例如 4~20mA 变送输出,则在仪表相应输出端串连一台万用 表,通过增大或减小校准系数,按 SET 键使输出值对应测量值如不对,再按加键 或减键,返回校准系数项,重复校验。按 Exit 键退出校准,先校准零点,再校 准满度。 注:根据订货要求,个别参数出厂时已被屏蔽。

键 5 秒)出现 PASS 时,输入 123,按 SEL(SEL 键)依

ON-S

;开机时分秒提示符

XXXX .XX

SEL

ON-y

XXXX.XX

;开机年月日提示符

十、通讯方式

1 、通讯协议:通用单片机 A S C I I 、串行口,每路模拟量寄存器占用四个字 节,数据类型;浮点数,起始寄存器 X300~X318,瞬时流量寄存器 X300,总累 计流量寄存器 X318,温度补偿 X304,压力补偿 X308;定量控制时,定量流量累 计寄存器 X316,总累计流量寄存器 X304,以亚控组态王人机界面举例。设备向 导:1、选智能模块,2、单片机,3、通用单片机 ASCII,4、串行口。下步操作 与其它智能表或 PLC 设置相同。如需更详细通讯协议请与我公司联系。

SEL OF-S

;关机时分秒提示符

XXXX .XX

SEL

OF-y XXXX .XX

;关机年月日提示符

十一、仪表端子接线图

SEL

tI-OFF CL-OFF

;时间设置提示符 ;按 ▲ 键显示 ON,再按键进入时钟设置 ;累积清零提示符 键显示 ON,再按键累积清零。 ▲

ON

SEL

ON

;按

;按 E xi t 键退出。

八、故障自动补偿

当使 用温 压 补偿 时 ,温度 、压力 测量 回 路出 现 故障 时 ,仪表 自 动使用键盘设定参数 P KE Y 、T KE Y 的值进行补偿;温度、压力测量 回路恢复正常 后,仪表自动使用 测量值进行 补偿。 ★故 障判 定条 件:热电 偶断 偶、热电 偶信 号线 反 接或 短路 、 P t 1 0 0 开路、C u 5 0 开路、错接信号线或者符合以下条件之一: P-HI

·1 3 ·

·6 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

操 作

SXL 系列

提示符 CB-D 按 SET ××××

流量显示积算仪 / 使用说明书

说 通讯地址 □□□□ 仪表通讯地址:0 ~9 9 9 波特率0:无通讯1:19200 2:9600 3:4800 4: 2400 5:1200 密码设置 原密码设置 明

★当使用温压补偿时,请正确设定压力正常值上限(P - H I ) 及压力正 常值下 限(P - L O ) 温度 正常 值 上限(T - H I )及温 度正 常值 下 限(T - L O ) 。 ★与补偿有关 的参数有: P - O O :孔板 设计 压 力值 ,单位: M p a 。t - O O :孔板 设 计 温 度 值,单位:℃。 P K E Y :故障补偿用压力 值,单位:M p a 。 T K E Y :故障 补 偿用 温 度值 ,单位:℃ 。 P - H I :压力正常值上限,单位:M p a 。 P - L O : 压力正常值下限,单位:M p a 。 t - HI : 温度正常值上限,单位:℃。 t - L O : 温度正常值下限 ,单位:℃。 t P -J: 补偿方式及介质类型。 ★ 参数 t P - J 说明: 千位 百位 十位 个位 出厂时值为1 ; 介质类型 0 :水 1 :天然气、煤气等气体。 2 :饱和蒸气。 3 :过热蒸气。 X :其他值时,默认为过热蒸气。 ; 补偿允许位 0 :不补 偿 ,1 :线性 补 偿 ,2 :开方 补 偿 。 1 :补偿。 X :其他值时,默认为补偿。 ; 压力自动补偿开关 0:压力测量回路故障时,自动采用 PKEY 的值补偿。 1:压力永远采用 PKEY 的值补偿,此时,按 键,下排数 码管可切显参数 P KE Y 的值,P K ××××。 ; 温度自动补偿开关 0:温度测量回路故障时,自动采用 TKE Y 的值补偿。 1:温度永远采用 TKEY 的值补偿此时,按 键,下排数码管 可切显参数 T K E Y 的值,T K ××××。 ;

按 SET

PASS ××××

3 、E 菜单的操作:此菜单是用于校验仪表输入测量精度的一 (表四) 组菜单,校验密码为 521。

操 作 按 SET 健 2秒 按 SET 提示符 PASS ×××× CH-1 AI AU CH-2 BI bRST USTb Ybcd CH-3 CI CU DA DA1L DA1H 说 明

按 SET

按 SET

进入密码选项 将随机设置为 521 按减键或加键改为 O N ,流量信号输入修正 流量电流信号输入修正系数 流量电压信号输入修正系数 按减键或加键改为 O N ,温补信号输入修正 温补电流信号输入修正系数 温补热电阻信号输入修正系数 温补 mv 信号输入修正系数 温补热电偶信号输入零点补偿修正系数 按减键或加键改为 O N ,压补信号输入修正 压补电流信号输入修正系数 压补电压信号输入修正系数

按减键或加键改为 ON,输出修正(不需外加信号)

按 SET

记录输出零点修正系数 记录输出满度修正系数

①补偿系数的校准

在热电偶方式下,按输入类型的补偿方式接线,短接热电偶输入端,应 显示常温值,如果不准,则进入补偿系数校准参数项(K BC D ) ,小于实际温度 则增大参数值,相反减小相应值。然后按设定键常温值,再按减键或加键,返 回校准参数项,重复上述工作,直到准确为止,按设定键进入下个参数。

②输入校准

按按输入类型,输入一定值(如量程上限值) ,如果不准确,就调整相应 的参数,使之符合要求。如果显示值大于设定量程值,按减键减小校准系数, 反之则增大。例如 4~20mA 控制输入,则在仪表相应输入端加入 20mA 信号,通 过增大或减小校准系数,按 SET 键使显示值为输入量程上限设定值如不对,再按 加键或减键,返回校准系数项,重复校验。同时按 S E T 键和减键退出校准。 零点 不用 校验 。

·7 ·

·1 2 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

操 作 按 SET 提示符 P1 ××××

流量显示积算仪 / 使用说明书

说 报警类型设定 □□□□显示面板

0 不报警 1 越上限报警(C 菜单不可看) 2 越下限报警(C 菜单不可看) 5 越上限报警(C 菜单可修改) 6 越下限报警(C 菜单可修改) 0 继电器触点闭合报警 1 继电器触点断开报警 0 报警时闪烁 1 报警时不闪烁 报警参数,见第四页。

SXL 系列

流量显示积算仪 / 使用说明书

按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET

AL1 ×× F1 ×× P2 ×××× AL2 ×××× F2 ×××× P3 ×××× AL3 ×××× F3 ×××× P4 ×××× AL4 ×××× F4(T) ×××× DAT ×××× DAH ×× DAL ×× tydA ××××

报警 值设 定(定 量控 制时 ,定量 值设 定) 工程量 报警回差 工程量,偏差值(定量控制时,此值无效) 报警类型设定: (与 P 1 含义相同

★★★ 仪表 开机 流量: 通电 —à 数码管全亮(测试数码管)—à 软件版本号 —à 瞬时流量 流量信号输入类型 累积流量 ★★★累积流量累积时间:每秒累积 1 次。 ★★★仪表运行时下排数码管按移位键时切换显示内容如下: 累积流量 à 压力通道值或键盘设定值(参数 P K ……)à 温度通 道值或键盘设定值(参数 T K ……)à 实时时间时、分、秒 à 实时 时间年、月、日;显示实时时间时,小数点闪烁。 ★★★仪表运行状态下,长按加键(按住加键 5 秒)时切换显示补偿前 流量及补偿后流量,当面板上的 COM 灯亮时,当前显示的流量为补偿前 流量(小信号切除) 。 ;———————————————————————————— ★★★ 仪表 故障 提示:

字符 BCLO BCHI OULO OUHI ntyP ItPO NSQR 意义 补偿温度< 0℃ 补偿温度> 50℃ 输入信号过低 输入信号过高 选择类型无效 系数溢出 负数开方 累积不保存 信号输入过高,频率信号过大,小数点位置不对 或信号太大或校正参数混乱,需初始化。 负数开方 表内电池需要更换 环境温度< 0℃ 补偿电阻未接好,补偿参数不对,类型选错或 环境温度> 50℃ 热电偶断偶,pt 10 0,c u5 0 接错或输入信号不对 或输入信号过低或校正系数过小。 校正系数过大或输入信号接法不对或输入信号 过高,热电偶断偶,p t 1 0 0 , c u 5 0 开路。 备注 补偿电阻未接好,补偿参数不对,类型选错或

报警值设定 工 程 量 (定 量 控 制时 ,定量 报 警 值) 报警回差 工程量,偏差值 报警类型设定 (与 P 1 含义相同) 报警值设定 工程量 报警回差 工程量,偏差值 报警类型设定 (与 P 1 含义相同) 报警值设定 工程量 报警回 差 (定量控制时,间隔时间值设定)

工程 量,偏差 值 变送输出参数选择

个位 0 : 补偿前流量;1 : 补偿后流量;2 : 压力;3 : 温度

参数小数位更改说明: 如下参数按 位改变,再按 移位键使小数点闪烁,按 移位键使小数点不闪烁,最后按 键或 键可使小数 键保存:

变送输出量程上限 变送输出量程下限 变送输出类型选择 个位0:0~10mA; 1:4~20mA; 2:1~5V

C(流量系数) 、AL1(第一个继电器报警设定值) 、F1(第一个继 电器报警回差) 、AL2、F2、AL3、F3、AL4、F4、H-F、L-F、JD--。 H-P、L-P、PKEY、POO、P-HI、P-LO 的小数位为 DOTP 的值。 H-T、L-T、TKEY、TOO、T-HI、T-LO 的小数位为 DOTT 的值。 ;————————————————————————————

·1 1 ·

·8 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

SXL 系列

流量显示积算仪 / 使用说明书

操 作 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET

SXL 系列

提示符

流量显示积算仪 / 使用说明书

(续表三) 九、功能菜单的操作

1 、C 菜单的操作:此菜单无密码,是操作工使用的菜单, 主要查看、修改 A L 1 、A L 2 、A L 3 、A L 4 参数。按 Q 键返回测量状 态 。

操 作 按S 键 按S 键 按S 键 按S 键 显示内容

AL1 XXXX AL2 XXXX AL3 XXXX AL4 XXXX

(表二)

含义及操作

在仪表测量状态下,按 S E T 键进入 C 的权限查看或修改 A L 1 参数。 在仪表测量状态下,按 S E T 键进入 C 的权限查看或修改 A L 2 参数。 在仪表测量状态下,按 S E T 键进入 C 的权限查看或修改 A L 3 参数。 在仪表测量状态下,按 S E T 键进入 C 的权限查看或修改 A L 4 参数。 菜单,根据 B 菜单 菜单,根据 B 菜单 菜单,根据 B 菜单 菜单,根据 B 菜单

压补输入信号类型 IN-P ×××× 二位代码(见附录仪表组态输入信号类型表) 压补显示小数点位数设定 DOTP 工程量 ×× 压补显示量程上限设定 H-P 工程量 ×× 压补显示量程下限设定 L-P 工程量 ×××× 流量累积小数点位数设定 DOTS ×××× 工程量 0 ~ 0 . 9 9 9 , 数值越大,抗干扰能力越强。个位为0,个位为0 , m3 / FILT ×××× h 单位灯亮、个位为1 , t / h 单位灯亮 、个位为2 , K g / h 单位灯亮 介质补偿 TP-J □□□□ ××× 0 不补偿,1 线性补偿 2 开方补偿

介质类型:0 水,1 气体,2 饱和蒸汽,3 过热蒸汽

2、B 菜单的操作:此菜单是仪表专业技术人员定义及选择仪表各 项功能的运行和控制方式的一组菜单。 B菜单包含C菜单中的所有选项, 并且定义 C 菜单中的选项是否可修改。按 Q 键退出设置。

1温度用健盘设定值(TKEY)补偿,tp-J 参数说明见第7 页 1 压力用健盘设定值(P K E Y )补偿

(表三)

按 SET 按 SET 按 SET 按 SET 按 SET

操 作 按 SET

提示符 PASS ×××× IN-F ×× DOTF ×× H-F ×××× L-F ×××× IN-T ×××× DOTT ×××× H-T ×××× L-T ××××

进入密码 随机数,设置为 1 1 1 ,P A S S 参数正确,进入 B 菜单 流量输入信号类型 二位代码(见附录仪表组态输入类型表)表八 瞬时流量显示小数点位数设定 (设定小数点时移位后, 按 移位键小数点不闪烁再按设定方可,是则出现乱码。 流量量程上限设定 工程量,小数点可移动 流量量程下限设定 工程量,小数点可移动 温补输入信号类型 二位代码(见附录仪表组态输入信号类型表) 温补显示小数点位数设定 工程量 温补显示量程上限设定 工程量 温补显示量程下限设定 工程量

按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET 按 SET

按 SET 按 SET 按 SET

按 SET 按 SET 按 SET 按 SET

测量介质密度,单位 Kg/m 3 , JD-。 ×××× 小数点可移动(出厂值 1000) 设计 额定 温度 。 T-00 , ×××× 工 程 量 ( 孔 板 设 计 温 度 ) 单 位 ℃ 设计 额定 压力 。 P-00 ,单位 M P a 。 ×××× 工程量(孔板设计压力) 小流量切除,三位小数点 FL00 ×××× 工程量(如:3 0 % 设为 0 . 3 0 0 ) 键盘设定补偿温度值 TKEY ×××× 工程量,单位℃, 键盘设定补偿压力值 PKEY ×××× 工程量单位 MPa。 温度正常值上限,工程量,单位℃ T-HI (实测温度值大于此值时用 TKEY 的值进行补偿) ×××× 温度正常值下限,工程量,单位℃ T-LO (实测温度值小于此值时用 TKEY 的值进行补偿) ×××× 压力正常值上限,工程量,单位 MPa。 P-HI (实测压力值大于此值时用 PKEY 的值进行补偿) ×××× 压力正常值下限,工程量,单位 MPa。 P-LO (实测压力值小于此值时用 PKEY 的值进行补偿) ×××× 涡街截止频率 J-FH ×××× 工程量: C 涡街流量系数( 单位:脉冲数 / 1 0 0 升) ×××× 工 程 量 :

·9 · ·1 0 ·

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn

智能流量积算仪使用说明


相关文章

  • 能量转换器说明书
  • 检测执行<JB/T 9248-1999电磁流量计> DL-X系列多功能 电磁流量转换积算仪 (基本型使用说明书) 杭州大吕科技有限公司 前 言 杭州大吕科技有限公司,是集研发.生产.销售为一体的高新技术型企业,在智能化仪表.工程 ...查看


  • 威力巴原理及计算公式
  • 威力巴流量计的工作原理及计算公式 摘要:介绍了威力巴流量计在测量气体和蒸汽流量时相应的温压补偿方式,分析了各温压补偿方式在DCS 系统和流量积算仪中的数学模型. 关键词:威力巴流量计:温压补偿:介质密度:分散控制系统:流量积算仪 Mathe ...查看


  • SB-2100流量积算仪说明书
  • SB-2100流量积算仪 金湖奥科仪表有限公司 金湖奥科仪表有限公司 SB-2100流量积算仪说明书流量积算仪说明书 前 言 长期以来,流量的计量一直是计量工作中的重点和难点,它直接影响着企业运行的稳定和企业成本的控制,同时,随着区域集中供 ...查看


  • 基于单片机流量控制与积算仪
  • 通过本设计,提高综合运用所学理论知识,分析和解决控制工程项目研制开发的能力.掌握利用先进技术.新型仪表及微计算机控制技术设计的基本方法和能力.以MCS-51为背景机掌握智能化仪表的设计过程和设计方法. 2.1  内容:流量检测与控制应用范围 ...查看


  • 智能流量积算仪多少钱
  • 上仪集团-国家大型一档企业 智能流量积算仪多少钱 键词:温度控制器.智能数字调节仪.智能流量积算仪.智能数字巡检仪.智能液位调节仪.电动调节阀.气动调节阀.单座调节阀.套筒调节阀.自力式调节阀 型智能流量积算仪采用高速高性能的运算芯片,先进 ...查看


  • 供热计量技术导则
  • 供热计量技术导则 2008年10月 1 总 则 ........................................ 1 2 集中供热系统热计量 ............................ 2 2.1 一般规定 . ...查看


  • 智能流量积算仪价格
  • 上仪集团-国家大型一档企业 智能流量积算仪价格 关键词:热电偶型号.高温热电偶.工业热电偶.热电偶原理.热电阻温度传感器.热电阻型号.热电阻工作原理.什么是热电阻.热电阻价格.双金属温度计是什么.变送器厂家.差压变送器.压力变送器工作原理. ...查看


  • 冲板流量计应用中出现的问题分析
  • 冲板流量计在重质碱生产中的应用 摘 要 对冲板流量计在南碱公司重质碱生产中使用及故障处理情况进行阐述 ,并结合实践 经验对该类仪表的使用维护提了相应的改进建议 . 关键词 冲板流量计轻质碱流量故障处理改进建议 广东南方碱业股份有限公司(以下 ...查看


  • 超声波流量计技术要求
  • 超声波流量计技术 1. 工作压力:2.5~3.8MPa 2. 使用温度:-20℃~80℃ 3. 精度等级:0.5 Qmin----0.1Qmax 0.1Qmax--------Qmax ≤±0.5% ≤±0.2% 4.防爆等级Exd ⅡBT ...查看