激光散斑血流成像系统

moorFLPI-2 – Capturing high resolution blood flow images in real time

The moorFLPI-2 blood flow imager uses the laser speckle contrast technique to deliver real-time, high-resolution blood flow images, providing outstanding performance in a wide range of pre-clinical and clinical research applications.

User-friendly features promote smooth workflow and enable the high through-put required to scan cohorts quickly and accurately. Advanced analysis functions help you to draw sound conclusions from your blood flow images. Product highlights include;• • • • •

Non contact imaging technique.

Blood flow videos of any exposed tissue (skin or surgically exposed tissues).

Best spatial resolution of 10 microns per pixel to reveal detailed morphology.

Real-time video frames rates to capture dynamic changes in flow.

Add multiple “regions of interest” to assess and quantify blood flow changes in real time and post measurement. Area of ROIs calculated automatically.•

Image areas range from 5.6mm x 7.5mm to 15cm x 20cm with motorised zoom and auto focus, offering flexible and convenient imaging.• •

Colour photo image matches blood flow images precisely to aid identification of features.Compact design with flexible stand options for clinic or laboratory for convenient use in various experimental and clinical research settings.

Provision of spatial and temporal measurement modes allow optimum selection between image frame rate and spatial resolution. Colour photo provided by the measurement camera simplifies identification of key features.

Triggering function enables control and synchronisation of

the moorFLPI-2 with other systems.

Technical advantages of Moor laser speckle are clear and include the use of motorised zoom and auto focus enabling the flexibility to image both small and large areas. The strength of the technique is two fold; video frame rate blood flow images enables the tracking of fast transients coupled with very high spatial resolution. It is possible to view pulsation in finger tips and spatial variations due to deep breath, occlusion, reactive hyperaemia and other stimuli.

The contrast image is processed to produce flux values that are colour-coded to correlate with blood flow in the tissue.

The laser speckle technique

The full-field laser perfusion technique, also known as laser speckle contrast imaging, exploits the random speckle pattern that is generated when tissue is illuminated by laser light and changes when blood cells move in the sampled tissue. When blood flow is high, the changing pattern becomes more blurred and the contrast in that region is reduced. Therefore high flow is related to low contrast and conversely low flow is associated with high contrast.

Low Power

CCD Camera Firewire & USB. Auto Focus & moorFLPI-2 – desktop setup.

Applications and software

Established pre-clinical and clinical research applications are wide-ranging; examples include;• • • • • • • •

Neuroscience – spreading cortical depression, stroke model assessment.

Dermatology – inflammation and irritancy research.Oncology – experimental tumour growth, angiogenesis.

Pharmacology – local and systemic responses.Plastic surgery – research into flap perfusion during surgery and post operatively.

Chemical toxicology – inflammation and irritancy (e.g. response to intradermal capsaicin).

Intraoperative measurements – limb and visceral ischaemia and reperfusion.

Cardiovascular research – e.g. endothelial function assessed with iontophoresis.

Dedicated software for measurement and analysis is provided to take advantage of the high acquisition speeds and spatial resolution provided by moorFLPI-2. moorFLPI-2 software has been refined over a number of years in response to our customer feedback and is fully featured for setup, measurement, analysis, reporting and exporting.

Setup offers full flexibility to choose scan size and temporal resolution, enabling you to collect data that is appropriate to your measurement, be it just a single image or a longer blood flow video. Zoom and auto focus is set easily using either the front panel buttons or via software control.

Measurement starts with a simple click. Mark events on the blood flow video and see changes in flow at pre-defined regions of interest (ROIs) that update graphically and histographically. Scan and ROI areas calculated automatically.

Analysis post measurement includes the ability to replay and re-analyse data offline by re-positioning regions of interest. This allows maximum utilisation of the data set. Five different colour palettes, and optional functions such as smoothing, image XY shift (to counteract movement mid measurement) and variable speed playback of blood flow videos enable you to present your data clearly.

Forearm – wheel, flare and axon reflex due to capsaicin injection. Scan area approximately 15 x 20cm.

Cerebral blood flow imaging – MCAO model showing baseline blood flow image. 10 micron resolution, intact skull. ROI analysis shows flow reduction.

Report templates can be custom defined to produce the analysis and reporting that is needed from your studies from standard statistical routines to FFT analysis.

Export data to AVI, Matlab and graphical forms to extend the use of data for further analysis or presentations.

Your research

Please contact Moor or your nearest approved distributor to discuss your specific application. Ask to see the new system in action and evaluate it at your own facility. Current publications using Moor laser speckle are wide

ranging and updated online at www.moor.co.uk.

Issue 1

About Moor Instruments

Moor Instruments, established in 1987, is a world leader in the design, manufacture and distribution of monitoring and imaging systems for micro-vascular assessments. We are proud now to include tissue oxygenation assessments within this portfolio.

Firsthand experience of laser Doppler research and development within Moor dates back to 1978 and with this we have the breadth of knowledge to help with your application and the enthusiasm to try and find answers to any of your questions.

By giving priority to performance, quality and service, we strive to ensure the highest levels of customer satisfaction.Our dedicated design team is involved with a number of development projects for other partners and manufacturers. Whatever your needs, as a researcher, clinician or manufacturer, Moor will work harder for you.

moorFLPI-2 with optional panel PC and MS3b mobile stand.

Specifications:

Quality Control

Moor Instruments is certified to ISO 13485: 2003. The moorFLPI-2 is CE certified.Measured Parameter Flux (tissue perfusion).Range 0 – 5000PU.

Accuracy ± 10% compared to a standard LDI measured from motility standard.Precision ± 3% of measured value.

Image size measurement accuracy ± 0.5mm or ± 5%, whichever is greater.Distance measurement accuracy ± 5%.Software

Windows based control, image processing and analysis.

External Trigger Input / Output

1 x trigger input, 1 x trigger output, 0-5v (TTL) level transition range. All outputs / inputs have independent user selectable scaling.

Zoom and Auto Focus

Controlled by motorised actuators via PC software or push buttons on scan head.Aiming Beam

Alignment of aiming beams at 25cm.

moorFLPI-2 – Capturing high resolution blood flow images in real time

The moorFLPI-2 blood flow imager uses the laser speckle contrast technique to deliver real-time, high-resolution blood flow images, providing outstanding performance in a wide range of pre-clinical and clinical research applications.

User-friendly features promote smooth workflow and enable the high through-put required to scan cohorts quickly and accurately. Advanced analysis functions help you to draw sound conclusions from your blood flow images. Product highlights include;• • • • •

Non contact imaging technique.

Blood flow videos of any exposed tissue (skin or surgically exposed tissues).

Best spatial resolution of 10 microns per pixel to reveal detailed morphology.

Real-time video frames rates to capture dynamic changes in flow.

Add multiple “regions of interest” to assess and quantify blood flow changes in real time and post measurement. Area of ROIs calculated automatically.•

Image areas range from 5.6mm x 7.5mm to 15cm x 20cm with motorised zoom and auto focus, offering flexible and convenient imaging.• •

Colour photo image matches blood flow images precisely to aid identification of features.Compact design with flexible stand options for clinic or laboratory for convenient use in various experimental and clinical research settings.

Provision of spatial and temporal measurement modes allow optimum selection between image frame rate and spatial resolution. Colour photo provided by the measurement camera simplifies identification of key features.

Triggering function enables control and synchronisation of

the moorFLPI-2 with other systems.

Technical advantages of Moor laser speckle are clear and include the use of motorised zoom and auto focus enabling the flexibility to image both small and large areas. The strength of the technique is two fold; video frame rate blood flow images enables the tracking of fast transients coupled with very high spatial resolution. It is possible to view pulsation in finger tips and spatial variations due to deep breath, occlusion, reactive hyperaemia and other stimuli.

The contrast image is processed to produce flux values that are colour-coded to correlate with blood flow in the tissue.

The laser speckle technique

The full-field laser perfusion technique, also known as laser speckle contrast imaging, exploits the random speckle pattern that is generated when tissue is illuminated by laser light and changes when blood cells move in the sampled tissue. When blood flow is high, the changing pattern becomes more blurred and the contrast in that region is reduced. Therefore high flow is related to low contrast and conversely low flow is associated with high contrast.

Low Power

CCD Camera Firewire & USB. Auto Focus & moorFLPI-2 – desktop setup.

Applications and software

Established pre-clinical and clinical research applications are wide-ranging; examples include;• • • • • • • •

Neuroscience – spreading cortical depression, stroke model assessment.

Dermatology – inflammation and irritancy research.Oncology – experimental tumour growth, angiogenesis.

Pharmacology – local and systemic responses.Plastic surgery – research into flap perfusion during surgery and post operatively.

Chemical toxicology – inflammation and irritancy (e.g. response to intradermal capsaicin).

Intraoperative measurements – limb and visceral ischaemia and reperfusion.

Cardiovascular research – e.g. endothelial function assessed with iontophoresis.

Dedicated software for measurement and analysis is provided to take advantage of the high acquisition speeds and spatial resolution provided by moorFLPI-2. moorFLPI-2 software has been refined over a number of years in response to our customer feedback and is fully featured for setup, measurement, analysis, reporting and exporting.

Setup offers full flexibility to choose scan size and temporal resolution, enabling you to collect data that is appropriate to your measurement, be it just a single image or a longer blood flow video. Zoom and auto focus is set easily using either the front panel buttons or via software control.

Measurement starts with a simple click. Mark events on the blood flow video and see changes in flow at pre-defined regions of interest (ROIs) that update graphically and histographically. Scan and ROI areas calculated automatically.

Analysis post measurement includes the ability to replay and re-analyse data offline by re-positioning regions of interest. This allows maximum utilisation of the data set. Five different colour palettes, and optional functions such as smoothing, image XY shift (to counteract movement mid measurement) and variable speed playback of blood flow videos enable you to present your data clearly.

Forearm – wheel, flare and axon reflex due to capsaicin injection. Scan area approximately 15 x 20cm.

Cerebral blood flow imaging – MCAO model showing baseline blood flow image. 10 micron resolution, intact skull. ROI analysis shows flow reduction.

Report templates can be custom defined to produce the analysis and reporting that is needed from your studies from standard statistical routines to FFT analysis.

Export data to AVI, Matlab and graphical forms to extend the use of data for further analysis or presentations.

Your research

Please contact Moor or your nearest approved distributor to discuss your specific application. Ask to see the new system in action and evaluate it at your own facility. Current publications using Moor laser speckle are wide

ranging and updated online at www.moor.co.uk.

Issue 1

About Moor Instruments

Moor Instruments, established in 1987, is a world leader in the design, manufacture and distribution of monitoring and imaging systems for micro-vascular assessments. We are proud now to include tissue oxygenation assessments within this portfolio.

Firsthand experience of laser Doppler research and development within Moor dates back to 1978 and with this we have the breadth of knowledge to help with your application and the enthusiasm to try and find answers to any of your questions.

By giving priority to performance, quality and service, we strive to ensure the highest levels of customer satisfaction.Our dedicated design team is involved with a number of development projects for other partners and manufacturers. Whatever your needs, as a researcher, clinician or manufacturer, Moor will work harder for you.

moorFLPI-2 with optional panel PC and MS3b mobile stand.

Specifications:

Quality Control

Moor Instruments is certified to ISO 13485: 2003. The moorFLPI-2 is CE certified.Measured Parameter Flux (tissue perfusion).Range 0 – 5000PU.

Accuracy ± 10% compared to a standard LDI measured from motility standard.Precision ± 3% of measured value.

Image size measurement accuracy ± 0.5mm or ± 5%, whichever is greater.Distance measurement accuracy ± 5%.Software

Windows based control, image processing and analysis.

External Trigger Input / Output

1 x trigger input, 1 x trigger output, 0-5v (TTL) level transition range. All outputs / inputs have independent user selectable scaling.

Zoom and Auto Focus

Controlled by motorised actuators via PC software or push buttons on scan head.Aiming Beam

Alignment of aiming beams at 25cm.


相关文章

  • 物理学在医学上的应用
  • 浅谈物理与医疗[摘要]:随 着近代物理学的迅速发展,以及人们对生命现象的认识逐步 深入,医学的各分支学科已愈来愈多地把它们的理论建立在 精确的物理科学基础上,物理学的技术和方法,在医学研究 和医疗实践中的应用也越来越广泛.就此兴起的医药物理 ...查看


  • 实习报告医院
  • 实习报告(医院) 下午1点15分,我们生物医学工程2000级全体同学,共30名,在学校大门集合完毕.1点30分,我们在张老师的带领下乘车前往本次实习的地点,重庆市中山医院. 在路途中,张老师为我们讲解了本次实习的目的及重点,并且提出了一些参 ...查看


  • 光声成像技术的最新进展
  • 第4卷第2期 2011年4月 2915(2011)02-0111-07文章编号1674- 中国光学 Chinese Optics Vol.4No.2 Apr.2011 光声成像技术的最新进展 张建英,谢文明,曾志平,李晖 (福建师范大学物理 ...查看


  • 大学物理实验-迈克尔逊干涉仪
  • 在大学物理实验中,使用的是传统迈克尔逊干涉仪,其常见的实验内容是:观察等倾干涉条纹,观察等厚干涉条纹,测量 激光或钠光的波长,测量钠光的双线波长差,测量玻璃的厚度或折射率等. 由于迈克尔逊干涉仪的调节具有一定的难度,人工计数又比较枯燥,所以 ...查看


  • 八年级语文下册测试卷_3
  • 八年级语文下册测试卷 1.下列字形和加点字注音全部正确的一项是( )(2分) A. 娴熟(xián) 真谛 和煦(xù) 相形见绌(chù) ... B. 凛冽(lín) 迁徙 诘责(jié) 深恶痛疾(wù) ... C. 缄默(jiān ...查看


  • 光学功能成像技术在乳腺癌早期诊断中的应用
  • () , , , (电子版) 2009年8月第3卷第4期C h i n JB r e a s tD i s E l e c t r o n i cE d i t i o n A u u s t 2009V o l . 3N o . 4g ㊃ ...查看


  • CFDA:[血液透析及相关治疗用水]等90项器械标准调整
  • 近期,国家食品药品监督管理总局 2015 年第 8 号公告发布了 YY 0572-2015<血液透析及相关治疗用水>等 90 项医疗器械行业标准,其中包括 14 项强制性标准和 76 项推荐性标准,涉及外科植入物.医用电器设备. ...查看


  • MR名词解释及简答
  • MR .名词解释 1.成像层面内的静止质子,如受到RF 脉冲反复激励将趋于饱和,信号变弱:而垂直流入成像层面不曾受到激励的"新鲜"质子,在成像层面内受到激励并经历复相位后,则可产生比周围静止质子信号强度更高的信号,并在进 ...查看


  • 荧光成像的原理和方法
  • 荧光成像的原理与方法 荧光成像在基因组学和蛋白质组学等生物学领域应用中的独特优势: 高灱敏度:灱敏度进超比色法,在大部分应用中其灱敏度近乎放射性同素. 多组样品一次成像:将不同样品(如:对照.处理)通过不同发射波长的荧光素标记(如 Cy3或 ...查看


热门内容