砖胎膜专项施工方案2013-2-28(审核版)

第一章 方案编制依据及意义 .........................................................................................................1

1. 编制依据 ....................................................................................................................1

2. 编制意义 ....................................................................................................................1

第二章 工程概况及施工准备 .........................................................................................................1

1. 用地概况 ....................................................................................................................1

2. 建设规模 ....................................................................................................................1 3. 功能布局 ....................................................................................................................2 4. 设计概况 ....................................................................................................................2

4.1. 施工现场现有情况 .............................................................................................2 5. 施工前准备 .................................................................................................................3

5.1. 材料准备 ...........................................................................................................3

第三章 资源配置计划....................................................................................................................4

1. 劳动力配置计划 ..........................................................................................................4

1.1. 劳动力安排原则 ................................................................................................4

1.2. 劳动力施工控制措施 .........................................................................................4 1.3. 施工现场劳动力配置 .........................................................................................5 1.4. 安全防护用品及施工工具一览表 ........................................................................5

第四章 施工流程及施工重点和技术要求........................................................................................5

1. 施工顺序 ....................................................................................................................6 2. 施工组重点和技术要求 ...............................................................................................6

2.1. 施工要求 ...........................................................................................................6 2.2. 土方开挖 ...........................................................................................................6 2.3. 垫层浇筑 ...........................................................................................................7 2.4. 砖胎膜设计 .......................................................................................................7 2.5. 地下室底板(筏板)及独立柱基砖胎膜施工 ...........................................................9 2.6. 砖胎膜砌筑 ..................................................................................................... 10 2.7. 砖胎膜砌筑 ..................................................................................................... 11 2.8. 砖胎膜侧土体回填 ........................................................................................... 11

2.9. 排水措施 ......................................................................................................... 12

第五章 质量要求及保证措施 ....................................................................................................... 12

1. 主控项目留槎的作法必须符合施工规范的规定 .......................................................... 12 2. 一般项目 .................................................................................................................. 12 3. 允许偏差 .................................................................................................................. 12 4. 砖胎膜施工注意事项: ............................................................................................. 13 5. 抹灰 ......................................................................................................................... 13 6. 工程质量保证措施 .................................................................................................... 13

6.1. 基本要求 ......................................................................................................... 13

6.2. 施工保证措施 .................................................................................................. 14 6.3. 质量保证体系 .................................................................................................. 14

第六章 安全保证措施.................................................................................................................. 15

1. 安全管理体系 ........................................................................................................... 15 2. 安全管理制度 ........................................................................................................... 15 3. 安全技术措施 ........................................................................................................... 16 4. 职工安全生产管理措施 ............................................................................................. 16

第一章 方案编制依据及意义

1. 编制依据

2. 编制意义

本工程施工顺序从南往北依次进行施工,目前南区我方已施工到了人工挖孔桩部分,由于本工程地下室防水采用的是外防水,如果底板侧壁、独立基础、筏板基础及集水井和电梯井用模板的话,将无法做外防水,所以模板采用砖胎膜的形式进行施工。由于是外防水,须在垫层上做防水,且防水要延伸到砖胎膜上,以便以后浇筑完混凝土后,防水能上翻到侧壁混凝土墙上,从而达到了外防水的效果,同时砖胎膜施工节约了工程成本和拆模工序。为确保施工安全,特编制砖胎膜专项施工方案,以便指导现场施工。

第二章 工程概况及施工准备

1. 用地概况

总规划用地面积7.36万平方米,地势西高东低。

2. 建设规模

总建筑面积约33.2万平米。(地下约12.49万平方米,地上20.71万平方米)

3. 功能布局

本工程为较大型城市综合体,包括六栋32层住宅塔楼、一栋23层酒店、一栋12层办公楼、四层商业裙楼(局部五层)、三层地下室。其中,裙楼屋面为花园及泳池;四层为影院、宴会厅;二、三层为商铺和餐饮;地下一层至一层为家乐福商场和商铺。首层在非商业区为小区花园;地下二层和三层为设备房、汽车库,局部为战时人防。

4. 设计概况

本工程为框架、框支剪力墙结构,一类高层建筑,建筑的设计使用年限为50年。抗震设防烈度为七度,建筑结构安全等级为二级。建筑物抗震设防类别:商业裙房在办公、酒店塔楼之间部分为乙类;其余均为丙类 。 4.1. 施工现场现有情况

由于本工程地下室防水采用的是外防水,采取砖胎膜代替模板施工,施工顺序从南往北依次进行施工,目前南区我方已施工到了基础部分(附南区施工现场图),部分塔吊基础砖胎膜已开始施工(附塔吊基础砖胎膜施工现场)。

5. 施工前准备

砖胎膜施工主要是采用M10干混砂浆、Mu10水泥标准砖砌筑。在施工准备阶段,根据现场施工要求,编制施工材料需用量,根据工地现场各专业施工现状,场地情况,确定材料进场日期、临时堆放场地,确保在不影响其他工序施工的同时,保证材料和施工人员到位。施工前要把场地清理干净,然后才能进行砌筑施工。 5.1. 材料准备

1)根据施工图,测算各种耗材的数量,作好定货安排,确定进场时间。 2)根据现场施工情况,编制材料进场计划。

3)主材:M10干混砂浆、Mu10水泥标准砖、混凝土等级C15、C20; 4)钢材:Φ12钢筋,Φ6箍筋。

第三章 资源配置计划

1. 劳动力配置计划

结合本工程的施工特点,依据劳动定额和本工程施工进度计划,合理配置本工程各施工阶段所必需配备的劳动力,在施工过程中根据实际进度要求,适时调整劳动力。 1.1. 劳动力安排原则

根据现场施工部署及工期进度统一安排,施工顺序从南区往北区进行施工,为确保进度,预计高峰期进场劳动力87人,具体施工各工种配置见附表1。

1)劳动力实行专业化组织,按不同工种,不同施工部位来划分作业班组。 2)根据本工程各阶段施工重点,相应调配各专业劳动力,实行动态管理。 3)各施工人员,必须接受建筑施工安全生产教育,经考试合格后方可上岗作业,未经建筑施工安全生产教育或考试不合格者,严禁上岗作业。

4)所有进场工人必须先通过三级安全教育,通过江门市统一组织的平安卡安全培训和考试,领取平安卡。未领平安卡者先上报入场登记名册,在项目部统一办理工作牌。

5)每道工序施工前技术人员必须对班组进行安全技术质量的交底。

6)强化对外施工人员的管理。用工手续必须齐全有效,严禁私招乱雇,杜绝违法用工。

1.2. 劳动力施工控制措施

1)施工现场项目经理及工长做到全盘考虑,认真研究施工阶段所需投入的人力,做到心中有数,以减少盲目性施工安排,避免造成需要的人力没有或不需要的人员窝工现象。

2)用人上采取竞争上岗的制度,选择技能熟练的工人,以确保施工质量符合要求。 3)工程进入收尾阶段时,要特别重视合理安排工序、交叉作业及成品保护,防止已完工的项目被损坏或污染,为此,应组织较多的人力进行竣工验收前的清理和保护工作。

1.3. 施工现场劳动力配置

1.4. 安全防护用品及施工工具一览表

附表4:

第四章 施工流程及施工重点和技术要求

1. 施工顺序

2. 施工组重点和技术要求

2.1. 施工要求

1)深基坑支护已由基坑的设计支护单位施工完成,经第三方监测,边坡的变形及位移在允许值范围内。

2)桩基础已检测合格。

3)土方开挖应根据土质情况进行放坡,放坡系数不得小于规范设计要求,若土质为强风化放坡系数为1:0.3,若土质为回填土,放坡系数为1:1。

4)承台、基础梁采用机械开挖至承台底标高以上250mm后采用人工挖掘、修整,防止对基土扰动,造成基土不稳。

5)在回填土过程中,严禁将素填土及塘泥作为底板的持力层,底板以下的素填土及塘泥应全部清除,并用不透水粘土分层夯实回填,夯填厚度为0.5m。基坑开挖完毕后,对土层做适当处理并清除浮土后应立即浇注基础垫层,严禁长期暴露坑底持力层。

6)组织好排水降水及防雨工作,防止发生边坡塌陷、基坑积水浸泡以及因抽水引起地下水位下降而造成承台基坑沉降,直到基坑回填完为止。 2.2. 土方开挖

本工程桩承台土方开挖是在桩边勾挖土方,如有桩顶被土覆盖,在开打挖时为避免对桩身的操作,先将桩顶表土刮开,找到桩的具体位置,然后把桩边的土方挖出来运走。承台土方开挖完成后,即进行基坑清理及人工修整,修整完成经检查后进行砼垫层浇筑。

土方开挖过程中如遇到承台间所剩距离不足1000mm时,需将这侧面距离内的土方

挖走,避免其塌方造成重复工作,影响工效。 2.3. 垫层浇筑

垫层浇筑前应在场地内进行标高定点,在完成承台、基础梁底修整土面上间距1m梅花形布置300长短钢筋头,以作为垫层厚度控制点。 2.4. 砖胎膜设计

根据施工图纸、施工组织设计要求,承台和基础梁等的侧模采用砖胎膜,因砖膜在砌好后要承受回填土的侧压力,砖胎膜的选型及厚度应根据承台、挡墙侧膜深度进行计算,防止回填土过程中或回填后由于地表水侵蚀而发生边坡滑移甚至垮塌。故砖膜基本选型和厚度如下表:

承台、挡土墙具体高度,按施工图纸标注为准,相关砖胎膜示意图如果下:

2.5. 地下室底板(筏板)及独立柱基砖胎膜施工

1)地下室底板及筏板:地下室裙楼底板及筏板基础外侧均为砖胎膜,采用灰砂砖及水泥砂浆砌筑,砖胎膜高度超过3米必须在中部增加一道钢筋混凝土圈梁,圈梁大小为厚度同墙厚,高度为240㎜,内配4Φ10钢筋,箍筋设置为Φ6@250, 混凝土等级为C20,以加大砖膜侧向抗压能力。

开挖后承台底土质较差,如淤泥、流砂,需进行C15素砼换填后再进入下一道工序,换填完成后在承台底部增加一道地圈梁,圈梁大小为厚度同墙厚,高度为240㎜,内配4Φ12钢筋,箍筋设置为Φ6@200,混凝土等级为C20。

墙长超过3米必须在中部设置一道砖柱,砖柱为(墙厚+120)㎜×(墙厚+120)㎜。在电梯井集水坑砖胎膜砌筑时先砌筑1500㎜高500㎜厚墙,然后在墙体上浇筑一道370㎜×300㎜的圈梁,后在圈梁上砌筑1500㎜高370㎜厚墙,然后砌筑240㎜厚墙到顶,砖膜砌筑完成必须增加斜撑回顶后方可进行C15素砼回填。

砖膜砌筑砂浆采用M10干混砂浆、Mu10水泥砖砌筑,24小时后方可回填施工。砖模高度超过1800mm, 必须增加斜撑回顶后方可进行回填。

2)地下室柱下独立基础:地下室柱下独立基础均采用砖胎膜砌筑,胎膜砌筑方法同扩展基础。

3)所有砖胎膜面均采用20厚M5干混砂浆抹面,抹灰面包括砖模内外侧及顶面。

2.6. 砖胎膜砌筑工艺

1)工艺流程

2.7. 砖胎膜砌筑

砖胎膜砌筑前,基础垫层表面应清扫干净,洒水湿润。先盘墙角,每次盘角高度不应超过五皮砖,随盘随靠平、吊直。

放线时,在砖胎膜内侧预留10mm的抹灰厚度,保证承台结构截面尺寸。

根据皮数杆最下面一层砖的底标高,拉线检查基础垫层表面标高,如第一层砖的水平灰缝大于20mm时,应先用细石混凝土找平,严禁在砌筑砂浆中掺细石代替或用砂浆垫平,更不允许砍砖找平。平整和垂直符合要求后再挂线砌墙。

组砌方法应正确,砌体上下应错缝,里外咬槎,采用“三一”砌砖法(即一铲灰,一块砖,一挤揉),严禁用水冲砂浆灌缝的方法。

灰缝厚度宜为10mm,且应饱满、平直、通顺,立缝砂浆应填实。应挤压碰头灰,防止透亮或瞎缝。

砖墙应拉通线砌筑,并应随砌随吊、靠,确保墙垂直、平整,不得砸砖修墙,几个人使用同一条通线,中间应设几个支线点,小线要拉紧,每层砖都要穿线看平,使水平灰缝均匀一致,平直通顺,砌筑时宜采用外手挂线,可以照顾砖墙两面平整。

砌砖时砖要放平,里手高,墙面就要张,里手低,墙面就要背,砌砖时一定要上跟线,下跟楞,左右相临要对平。

墙体标高不一致或有局部加深部位,应从最低处往上砌筑,应经常拉线检查,以保持砌体通顺、平直,防止砌成“螺丝”墙。

2.8. 砖胎膜侧回填

1、土料要求

本工程按设计要求对砖胎膜后边操作面回填质量要求:

a、为满足基础砖胎膜施工操作面,在基础土方开挖时,会比原基础尺寸开挖尺寸要大,人工修坡时将侧壁土体修成斜面,底部距砖胎膜150mm宽,顶部距离200mm。为确保地基承载力要求,按设计该部分空间应用C15素砼填塞。

b、大面积要求级配砂石夯填,或撼砂处理并注意安全。

2、级配砂石要求

根据现场实际情况,优先采用天然级配砂石,若无天然级配砂石,采用砂:石=7:3的人工级配砂石。

3、基底处理

场地回填应先清除基底上草皮、树根、坑穴中积水、淤泥和杂物,采取措施防

止地表滞水流入填方区,浸泡地基,造成基土下陷。

4、砖胎膜外侧回填方法

(1)在底板地面100厚C15垫层施工时,直接该垫层混凝土回填砖胎膜侧面的操作空隙,平面采用平板振动器进行挣捣,砖胎膜侧壁处回填混凝土采用振动棒进行振捣密实。

(2)对于基础较深的部位,砖模高度超过1m的,回填混凝土应分层浇捣,防止砖胎膜暴模变形。每次浇筑深度不宜大于500mm,分层间隔时间小于混凝土初凝时间。

(3)应先施工回填混凝土,再浇筑底板垫层混凝土,两者之间不得出现施工冷缝。

2.9. 排水措施

土方及地下室施工期间,为防雨水对基坑的冲刷浸泡,造成塌方、泥浆污染及基坑积水,应做好排水措施。在基坑底,沿底板外围用砖砌排水沟和集水井,排水沟和集水井的设置、做法,详见《地下室临时抽排水施工方案》。

土方开挖过程中应注意到,由于场地狭窄,故留设临时道路,临时道路留设时,要满足:①便于机动车辆的行驶和回旋半径; ②路基不易受到塌方和雨水浸泡的危胁:③应尽可能避开承台的要求,以利各方施工。

第五章 质量要求及保证措施

1. 主控项目留槎的作法必须符合施工规范的规定

1)砖的品种、强度等级必须符合设计要求。

2)砂浆品种符合设计要求。

3)砌体砂浆必须饱满密实,实心砖砌体水平灰缝的砂浆饱满度不小于80%。

4)转角处严禁留直槎,其它临时间断处,。

2. 一般项目

1)砖砌体上下错缝,每处无长度超过500mm以上的通缝。

2)砖砌体接槎处灰缝砂浆密实,缝、砖应平直。

3. 允许偏差

4. 砖胎膜施工注意事项:

(1)做好施工人员现场技术交底,不能盲目进行施工;

(2)严格按照技术规范和方案要求进行操作施工;

(3)砖胎膜砌筑高度过高需分段砌筑,一次砌筑高度不得超过1500㎜;

(4)砖胎膜砌筑完成后应待24小时后方可进行混凝土回填施工;

(5)做好地表水排放,防止地表水浸入回填土内,造成回填土质量问题;

(6)土方及地下室施工在雨季期内进行,砼垫层及砌砖膜、抹灰工作不宜采用成片施工的方法,若采用成片成段施工极易受到不可预测的雨天的侵扰,应按承台个数和小面积进行。对每天工程量进行合理安排,合理组织人力,对开挖完成后的承台基础梁及时进行砌筑胎膜、垫层施工,防止地表水侵蚀而造成返工。

5. 抹灰

砖胎膜砌筑完毕,用M5干混砂浆在砖胎膜内外侧及顶面抹灰,抹灰厚度20mm。 抹灰的面层不得有爆灰和裂缝且表面应光滑、洁净、接搓平顺、线角顺直平直。各层抹灰之间及抹灰层和基层之间必须粘结牢固,不得有脱层空鼓。

立面垂直度允许偏差3mm,表面平整度允许偏差3mm,阴阳角方正,允许偏差3mm。

6. 工程质量保证措施

6.1. 基本要求

(1)严格按照公司质量保证的要求开展工作,使质量工作贯穿于各个部门、各个环节、各道工序。

(2)抓好质量预控和质量意识教育。组织施工人员学习施工规范、操作规程和质量检查标准,进行技术交底和质量通病防治教育,使施工人员了解工程概况,掌握工程要领及质量要求,做到人人心中有标准,个个心中求质量。

(3)严把质量关。选用优质的设备,对工程中使用的各种设备把住采购和验收两

个关。

(4)坚持三级检查验收制度,严把分项工程验收关。在每个分项或工序施工过程中,认真执行操作班自检、施工员全面检、质量员核验检三道关。

(5) 建立工程质量保证体系和质量管理责任制,做好各级质量交底。

6.2. 施工保证措施

(1)组织技术交底,向班组进行技术操作和质量标准的交底工作;

(2)严格按设计图、施工方案和施工规范等组织指导施工;

(3)砖胎膜砌筑前,复核结构截面尺寸、标高;

(4)砌筑砖胎膜时,基坑周边必须做好防护,预防砖胎膜垮塌;

(5)及时排清基坑积水,避免基坑长期浸泡。若砖胎膜有裂隙,应作必要的填补,必要时拆除重新砌筑。

6.3. 质量保证体系

6.3.1. 质量保证体系:

实行全面、全员、全过程中的质量管理建立由班组、施工队、项目部组成的三级质量保证体系,定期召开质量分析会,对存在的问题全面分析,找出原因,制定对策,确保质量。施工过程中严格遵守监理程序,服从监理工程师各项指令。

1、加强技术管理:认真贯彻各项目技术管理制度、开工前落实各项人员岗位责任制,做好技术交底,使每个施工人员做到对工程的总体要求明确,对本岗位职责、质量和技术要求有深刻了解。

2、实行项目技术负责人质量负责制,建立完善的质量管理和质量信息网络,项目技术负责领导下的质量管理小组,具有检查、监督、指导各班组、各工序的工作质量和工作成果的权利,并将检查结果上报项目经理部,做为考核班组和个人的依据并与经济收入挂钩。

3、对影响成果质量的关键工序明确责任人,前一道工序对下道工序负责,凡不符合质量标准的前道工序不纠正不得转入下道工序。

4、实行质检员24小时跟班作业制度,严格掌握各工序的质量标准,防患于未然。

5、认真做好各种原始记录施工日记,做到准确、及时、齐全,整理汇总反馈信息,进一步指导施工。

6.3.2. 组织保证措施

(1)项目经理为工程质量第一责任人,对质量安全负全责;

(2)项目经理部的所有施工人员在项目经理的统一指挥下,分工协作负责督促检查各工种施工质量;

(3)施工人员组织情况及具体分工如下表:

(4)整个工程施工,均应在监理工程师的监督下进行。

第六章 安全保证措施

1. 安全管理体系

建立健全安全生产保证体系,贯彻国家有关安全生产和劳动保护方面的法律、法规,研究项目安全生产工作,发现问题,及时处理解决。逐级签订安全施工合同,使各级明确

自己的安全目标,达到全面管理,消除事故隐患,实现安全生产的目的。

2. 安全管理制度

1、坚持预防为主的原则,防患于未然,现场成立安全生产领导小组。设专职安全员,建立安全生产管理网络,经常检查督促安全生产,每周两次安全例会,强化安全意识,落实安全措施,做到人人关心生产重视安全。

2、进入现场施工人员均必须穿戴劳保用品,配戴安全帽,遵守建筑安全操作规程和有关规定,各安全口挂设警示牌。

3、所有机械操作人员均应有操作合格证,设备要经常检查,不可带病运转使用。

4、现场24小时有专职电工值班,电器设备均要安装漏电保护器。

5、严禁坑边大量堆放砖,基坑边严格按要求控制荷载,避免堆砖过高导致基坑塌方或砖垮塌。

6、加强安全监控措施,必要时采取相应的应急措施,加以补救。

3. 安全技术措施

(1)根据本工程场地、机械施工、配合工种多的特点,制定安全措施,建立安全责任制并定期开展安全活动。

(2)各种机械,各工种要遵守各自的安全操作规程.注意相互间的安全距离,施工机械不得撞击排水管、测量基点等。

(4)现场出入口要设安全岗,配备专人指挥运砖、砂浆车辆,汽车司机要遵守交通法规和有关规定,按指定路线行驶,按指定地点卸砖、砂浆。

(5) 要遵守本地区,本工地安全、保卫、消防、市容,环卫,交通等管理规定。要加强工人的管理教育,工人要有“三证”,做到合法用工,上岗前要进行安全交底和安全教育。

4. 职工安全生产管理措施

(l)建立健全安全机构,配备安全管理人员。公司、项目部二级分别设立安全领导小组、安全管理小组,设置公司安全监督部、项目施工安全组作业专职管理部门,各级都配备足够的符合要求的安全管理人员.实行专管与群管相结合的管理体系,横向到边,纵向到底,形成管理网络。

(2)建立以安全生产责任制为核心的各项安全管理制度。主要包括各级各类人员的安全生产责任制、安全生产目标管理制度、安全检查制度、安全教育制度、安全技术措施计划制度、安全交底制度、特种作业人员管理制度、安全验收制度、班组安全活动制度、事故报告与调查处理制度、安全奖罚制度等。安全生产责任目标层层分解。落实到人,严格考核结果与经济挂钩。

(3)强化安全教育,加强人员管理。加强现场管理人员的安全意识,使每一个管理人员做到关心安全并在实际的管理工作中坚持做到安全第一,认真履行职责、严格执行三级安全教育和安全交底制度,未经教育和交底的人员不准上岗作业。坚持经常性教育,教育职工由“要我安全’变为“我要安全”。特种作业人员必须持有效操作证上岗。严格人员管理,规范用工,严肃查处违章操作和违反劳动纪律的行为,使员工做到不伤害自己、不伤害他人、不被他人伤害。

(4)严格监督检查,消除事故隐患。公司每季度定期检查,平时抽查;项目部每月定期检查,平时抽查;项目经理和安全员坚持每日安全巡视,对检查发现的事故隐患,定人、定期进行处理。

(5)对全体施工员工进行安全教育,牢固树立“生产必须安全,安全为了生产”及“安全第一、预防为主、综合治理”的思想。

(6)安全员必须经常在现场检查监督,施工人员必须服从安全员的管理。经常开展安全活动,杜绝各种事故发生。

(7)进入现场必须戴安全帽,禁止赤脚及穿拖鞋。

(8)做好设备保养,防护设备安全可靠,机械运转正常。

(9)电器系统必须保持干燥,装好漏电开关,定期检修。经常检查电线、电路情况,如发现线路老化、破损等应及时更换。

第一章 方案编制依据及意义 .........................................................................................................1

1. 编制依据 ....................................................................................................................1

2. 编制意义 ....................................................................................................................1

第二章 工程概况及施工准备 .........................................................................................................1

1. 用地概况 ....................................................................................................................1

2. 建设规模 ....................................................................................................................1 3. 功能布局 ....................................................................................................................2 4. 设计概况 ....................................................................................................................2

4.1. 施工现场现有情况 .............................................................................................2 5. 施工前准备 .................................................................................................................3

5.1. 材料准备 ...........................................................................................................3

第三章 资源配置计划....................................................................................................................4

1. 劳动力配置计划 ..........................................................................................................4

1.1. 劳动力安排原则 ................................................................................................4

1.2. 劳动力施工控制措施 .........................................................................................4 1.3. 施工现场劳动力配置 .........................................................................................5 1.4. 安全防护用品及施工工具一览表 ........................................................................5

第四章 施工流程及施工重点和技术要求........................................................................................5

1. 施工顺序 ....................................................................................................................6 2. 施工组重点和技术要求 ...............................................................................................6

2.1. 施工要求 ...........................................................................................................6 2.2. 土方开挖 ...........................................................................................................6 2.3. 垫层浇筑 ...........................................................................................................7 2.4. 砖胎膜设计 .......................................................................................................7 2.5. 地下室底板(筏板)及独立柱基砖胎膜施工 ...........................................................9 2.6. 砖胎膜砌筑 ..................................................................................................... 10 2.7. 砖胎膜砌筑 ..................................................................................................... 11 2.8. 砖胎膜侧土体回填 ........................................................................................... 11

2.9. 排水措施 ......................................................................................................... 12

第五章 质量要求及保证措施 ....................................................................................................... 12

1. 主控项目留槎的作法必须符合施工规范的规定 .......................................................... 12 2. 一般项目 .................................................................................................................. 12 3. 允许偏差 .................................................................................................................. 12 4. 砖胎膜施工注意事项: ............................................................................................. 13 5. 抹灰 ......................................................................................................................... 13 6. 工程质量保证措施 .................................................................................................... 13

6.1. 基本要求 ......................................................................................................... 13

6.2. 施工保证措施 .................................................................................................. 14 6.3. 质量保证体系 .................................................................................................. 14

第六章 安全保证措施.................................................................................................................. 15

1. 安全管理体系 ........................................................................................................... 15 2. 安全管理制度 ........................................................................................................... 15 3. 安全技术措施 ........................................................................................................... 16 4. 职工安全生产管理措施 ............................................................................................. 16

第一章 方案编制依据及意义

1. 编制依据

2. 编制意义

本工程施工顺序从南往北依次进行施工,目前南区我方已施工到了人工挖孔桩部分,由于本工程地下室防水采用的是外防水,如果底板侧壁、独立基础、筏板基础及集水井和电梯井用模板的话,将无法做外防水,所以模板采用砖胎膜的形式进行施工。由于是外防水,须在垫层上做防水,且防水要延伸到砖胎膜上,以便以后浇筑完混凝土后,防水能上翻到侧壁混凝土墙上,从而达到了外防水的效果,同时砖胎膜施工节约了工程成本和拆模工序。为确保施工安全,特编制砖胎膜专项施工方案,以便指导现场施工。

第二章 工程概况及施工准备

1. 用地概况

总规划用地面积7.36万平方米,地势西高东低。

2. 建设规模

总建筑面积约33.2万平米。(地下约12.49万平方米,地上20.71万平方米)

3. 功能布局

本工程为较大型城市综合体,包括六栋32层住宅塔楼、一栋23层酒店、一栋12层办公楼、四层商业裙楼(局部五层)、三层地下室。其中,裙楼屋面为花园及泳池;四层为影院、宴会厅;二、三层为商铺和餐饮;地下一层至一层为家乐福商场和商铺。首层在非商业区为小区花园;地下二层和三层为设备房、汽车库,局部为战时人防。

4. 设计概况

本工程为框架、框支剪力墙结构,一类高层建筑,建筑的设计使用年限为50年。抗震设防烈度为七度,建筑结构安全等级为二级。建筑物抗震设防类别:商业裙房在办公、酒店塔楼之间部分为乙类;其余均为丙类 。 4.1. 施工现场现有情况

由于本工程地下室防水采用的是外防水,采取砖胎膜代替模板施工,施工顺序从南往北依次进行施工,目前南区我方已施工到了基础部分(附南区施工现场图),部分塔吊基础砖胎膜已开始施工(附塔吊基础砖胎膜施工现场)。

5. 施工前准备

砖胎膜施工主要是采用M10干混砂浆、Mu10水泥标准砖砌筑。在施工准备阶段,根据现场施工要求,编制施工材料需用量,根据工地现场各专业施工现状,场地情况,确定材料进场日期、临时堆放场地,确保在不影响其他工序施工的同时,保证材料和施工人员到位。施工前要把场地清理干净,然后才能进行砌筑施工。 5.1. 材料准备

1)根据施工图,测算各种耗材的数量,作好定货安排,确定进场时间。 2)根据现场施工情况,编制材料进场计划。

3)主材:M10干混砂浆、Mu10水泥标准砖、混凝土等级C15、C20; 4)钢材:Φ12钢筋,Φ6箍筋。

第三章 资源配置计划

1. 劳动力配置计划

结合本工程的施工特点,依据劳动定额和本工程施工进度计划,合理配置本工程各施工阶段所必需配备的劳动力,在施工过程中根据实际进度要求,适时调整劳动力。 1.1. 劳动力安排原则

根据现场施工部署及工期进度统一安排,施工顺序从南区往北区进行施工,为确保进度,预计高峰期进场劳动力87人,具体施工各工种配置见附表1。

1)劳动力实行专业化组织,按不同工种,不同施工部位来划分作业班组。 2)根据本工程各阶段施工重点,相应调配各专业劳动力,实行动态管理。 3)各施工人员,必须接受建筑施工安全生产教育,经考试合格后方可上岗作业,未经建筑施工安全生产教育或考试不合格者,严禁上岗作业。

4)所有进场工人必须先通过三级安全教育,通过江门市统一组织的平安卡安全培训和考试,领取平安卡。未领平安卡者先上报入场登记名册,在项目部统一办理工作牌。

5)每道工序施工前技术人员必须对班组进行安全技术质量的交底。

6)强化对外施工人员的管理。用工手续必须齐全有效,严禁私招乱雇,杜绝违法用工。

1.2. 劳动力施工控制措施

1)施工现场项目经理及工长做到全盘考虑,认真研究施工阶段所需投入的人力,做到心中有数,以减少盲目性施工安排,避免造成需要的人力没有或不需要的人员窝工现象。

2)用人上采取竞争上岗的制度,选择技能熟练的工人,以确保施工质量符合要求。 3)工程进入收尾阶段时,要特别重视合理安排工序、交叉作业及成品保护,防止已完工的项目被损坏或污染,为此,应组织较多的人力进行竣工验收前的清理和保护工作。

1.3. 施工现场劳动力配置

1.4. 安全防护用品及施工工具一览表

附表4:

第四章 施工流程及施工重点和技术要求

1. 施工顺序

2. 施工组重点和技术要求

2.1. 施工要求

1)深基坑支护已由基坑的设计支护单位施工完成,经第三方监测,边坡的变形及位移在允许值范围内。

2)桩基础已检测合格。

3)土方开挖应根据土质情况进行放坡,放坡系数不得小于规范设计要求,若土质为强风化放坡系数为1:0.3,若土质为回填土,放坡系数为1:1。

4)承台、基础梁采用机械开挖至承台底标高以上250mm后采用人工挖掘、修整,防止对基土扰动,造成基土不稳。

5)在回填土过程中,严禁将素填土及塘泥作为底板的持力层,底板以下的素填土及塘泥应全部清除,并用不透水粘土分层夯实回填,夯填厚度为0.5m。基坑开挖完毕后,对土层做适当处理并清除浮土后应立即浇注基础垫层,严禁长期暴露坑底持力层。

6)组织好排水降水及防雨工作,防止发生边坡塌陷、基坑积水浸泡以及因抽水引起地下水位下降而造成承台基坑沉降,直到基坑回填完为止。 2.2. 土方开挖

本工程桩承台土方开挖是在桩边勾挖土方,如有桩顶被土覆盖,在开打挖时为避免对桩身的操作,先将桩顶表土刮开,找到桩的具体位置,然后把桩边的土方挖出来运走。承台土方开挖完成后,即进行基坑清理及人工修整,修整完成经检查后进行砼垫层浇筑。

土方开挖过程中如遇到承台间所剩距离不足1000mm时,需将这侧面距离内的土方

挖走,避免其塌方造成重复工作,影响工效。 2.3. 垫层浇筑

垫层浇筑前应在场地内进行标高定点,在完成承台、基础梁底修整土面上间距1m梅花形布置300长短钢筋头,以作为垫层厚度控制点。 2.4. 砖胎膜设计

根据施工图纸、施工组织设计要求,承台和基础梁等的侧模采用砖胎膜,因砖膜在砌好后要承受回填土的侧压力,砖胎膜的选型及厚度应根据承台、挡墙侧膜深度进行计算,防止回填土过程中或回填后由于地表水侵蚀而发生边坡滑移甚至垮塌。故砖膜基本选型和厚度如下表:

承台、挡土墙具体高度,按施工图纸标注为准,相关砖胎膜示意图如果下:

2.5. 地下室底板(筏板)及独立柱基砖胎膜施工

1)地下室底板及筏板:地下室裙楼底板及筏板基础外侧均为砖胎膜,采用灰砂砖及水泥砂浆砌筑,砖胎膜高度超过3米必须在中部增加一道钢筋混凝土圈梁,圈梁大小为厚度同墙厚,高度为240㎜,内配4Φ10钢筋,箍筋设置为Φ6@250, 混凝土等级为C20,以加大砖膜侧向抗压能力。

开挖后承台底土质较差,如淤泥、流砂,需进行C15素砼换填后再进入下一道工序,换填完成后在承台底部增加一道地圈梁,圈梁大小为厚度同墙厚,高度为240㎜,内配4Φ12钢筋,箍筋设置为Φ6@200,混凝土等级为C20。

墙长超过3米必须在中部设置一道砖柱,砖柱为(墙厚+120)㎜×(墙厚+120)㎜。在电梯井集水坑砖胎膜砌筑时先砌筑1500㎜高500㎜厚墙,然后在墙体上浇筑一道370㎜×300㎜的圈梁,后在圈梁上砌筑1500㎜高370㎜厚墙,然后砌筑240㎜厚墙到顶,砖膜砌筑完成必须增加斜撑回顶后方可进行C15素砼回填。

砖膜砌筑砂浆采用M10干混砂浆、Mu10水泥砖砌筑,24小时后方可回填施工。砖模高度超过1800mm, 必须增加斜撑回顶后方可进行回填。

2)地下室柱下独立基础:地下室柱下独立基础均采用砖胎膜砌筑,胎膜砌筑方法同扩展基础。

3)所有砖胎膜面均采用20厚M5干混砂浆抹面,抹灰面包括砖模内外侧及顶面。

2.6. 砖胎膜砌筑工艺

1)工艺流程

2.7. 砖胎膜砌筑

砖胎膜砌筑前,基础垫层表面应清扫干净,洒水湿润。先盘墙角,每次盘角高度不应超过五皮砖,随盘随靠平、吊直。

放线时,在砖胎膜内侧预留10mm的抹灰厚度,保证承台结构截面尺寸。

根据皮数杆最下面一层砖的底标高,拉线检查基础垫层表面标高,如第一层砖的水平灰缝大于20mm时,应先用细石混凝土找平,严禁在砌筑砂浆中掺细石代替或用砂浆垫平,更不允许砍砖找平。平整和垂直符合要求后再挂线砌墙。

组砌方法应正确,砌体上下应错缝,里外咬槎,采用“三一”砌砖法(即一铲灰,一块砖,一挤揉),严禁用水冲砂浆灌缝的方法。

灰缝厚度宜为10mm,且应饱满、平直、通顺,立缝砂浆应填实。应挤压碰头灰,防止透亮或瞎缝。

砖墙应拉通线砌筑,并应随砌随吊、靠,确保墙垂直、平整,不得砸砖修墙,几个人使用同一条通线,中间应设几个支线点,小线要拉紧,每层砖都要穿线看平,使水平灰缝均匀一致,平直通顺,砌筑时宜采用外手挂线,可以照顾砖墙两面平整。

砌砖时砖要放平,里手高,墙面就要张,里手低,墙面就要背,砌砖时一定要上跟线,下跟楞,左右相临要对平。

墙体标高不一致或有局部加深部位,应从最低处往上砌筑,应经常拉线检查,以保持砌体通顺、平直,防止砌成“螺丝”墙。

2.8. 砖胎膜侧回填

1、土料要求

本工程按设计要求对砖胎膜后边操作面回填质量要求:

a、为满足基础砖胎膜施工操作面,在基础土方开挖时,会比原基础尺寸开挖尺寸要大,人工修坡时将侧壁土体修成斜面,底部距砖胎膜150mm宽,顶部距离200mm。为确保地基承载力要求,按设计该部分空间应用C15素砼填塞。

b、大面积要求级配砂石夯填,或撼砂处理并注意安全。

2、级配砂石要求

根据现场实际情况,优先采用天然级配砂石,若无天然级配砂石,采用砂:石=7:3的人工级配砂石。

3、基底处理

场地回填应先清除基底上草皮、树根、坑穴中积水、淤泥和杂物,采取措施防

止地表滞水流入填方区,浸泡地基,造成基土下陷。

4、砖胎膜外侧回填方法

(1)在底板地面100厚C15垫层施工时,直接该垫层混凝土回填砖胎膜侧面的操作空隙,平面采用平板振动器进行挣捣,砖胎膜侧壁处回填混凝土采用振动棒进行振捣密实。

(2)对于基础较深的部位,砖模高度超过1m的,回填混凝土应分层浇捣,防止砖胎膜暴模变形。每次浇筑深度不宜大于500mm,分层间隔时间小于混凝土初凝时间。

(3)应先施工回填混凝土,再浇筑底板垫层混凝土,两者之间不得出现施工冷缝。

2.9. 排水措施

土方及地下室施工期间,为防雨水对基坑的冲刷浸泡,造成塌方、泥浆污染及基坑积水,应做好排水措施。在基坑底,沿底板外围用砖砌排水沟和集水井,排水沟和集水井的设置、做法,详见《地下室临时抽排水施工方案》。

土方开挖过程中应注意到,由于场地狭窄,故留设临时道路,临时道路留设时,要满足:①便于机动车辆的行驶和回旋半径; ②路基不易受到塌方和雨水浸泡的危胁:③应尽可能避开承台的要求,以利各方施工。

第五章 质量要求及保证措施

1. 主控项目留槎的作法必须符合施工规范的规定

1)砖的品种、强度等级必须符合设计要求。

2)砂浆品种符合设计要求。

3)砌体砂浆必须饱满密实,实心砖砌体水平灰缝的砂浆饱满度不小于80%。

4)转角处严禁留直槎,其它临时间断处,。

2. 一般项目

1)砖砌体上下错缝,每处无长度超过500mm以上的通缝。

2)砖砌体接槎处灰缝砂浆密实,缝、砖应平直。

3. 允许偏差

4. 砖胎膜施工注意事项:

(1)做好施工人员现场技术交底,不能盲目进行施工;

(2)严格按照技术规范和方案要求进行操作施工;

(3)砖胎膜砌筑高度过高需分段砌筑,一次砌筑高度不得超过1500㎜;

(4)砖胎膜砌筑完成后应待24小时后方可进行混凝土回填施工;

(5)做好地表水排放,防止地表水浸入回填土内,造成回填土质量问题;

(6)土方及地下室施工在雨季期内进行,砼垫层及砌砖膜、抹灰工作不宜采用成片施工的方法,若采用成片成段施工极易受到不可预测的雨天的侵扰,应按承台个数和小面积进行。对每天工程量进行合理安排,合理组织人力,对开挖完成后的承台基础梁及时进行砌筑胎膜、垫层施工,防止地表水侵蚀而造成返工。

5. 抹灰

砖胎膜砌筑完毕,用M5干混砂浆在砖胎膜内外侧及顶面抹灰,抹灰厚度20mm。 抹灰的面层不得有爆灰和裂缝且表面应光滑、洁净、接搓平顺、线角顺直平直。各层抹灰之间及抹灰层和基层之间必须粘结牢固,不得有脱层空鼓。

立面垂直度允许偏差3mm,表面平整度允许偏差3mm,阴阳角方正,允许偏差3mm。

6. 工程质量保证措施

6.1. 基本要求

(1)严格按照公司质量保证的要求开展工作,使质量工作贯穿于各个部门、各个环节、各道工序。

(2)抓好质量预控和质量意识教育。组织施工人员学习施工规范、操作规程和质量检查标准,进行技术交底和质量通病防治教育,使施工人员了解工程概况,掌握工程要领及质量要求,做到人人心中有标准,个个心中求质量。

(3)严把质量关。选用优质的设备,对工程中使用的各种设备把住采购和验收两

个关。

(4)坚持三级检查验收制度,严把分项工程验收关。在每个分项或工序施工过程中,认真执行操作班自检、施工员全面检、质量员核验检三道关。

(5) 建立工程质量保证体系和质量管理责任制,做好各级质量交底。

6.2. 施工保证措施

(1)组织技术交底,向班组进行技术操作和质量标准的交底工作;

(2)严格按设计图、施工方案和施工规范等组织指导施工;

(3)砖胎膜砌筑前,复核结构截面尺寸、标高;

(4)砌筑砖胎膜时,基坑周边必须做好防护,预防砖胎膜垮塌;

(5)及时排清基坑积水,避免基坑长期浸泡。若砖胎膜有裂隙,应作必要的填补,必要时拆除重新砌筑。

6.3. 质量保证体系

6.3.1. 质量保证体系:

实行全面、全员、全过程中的质量管理建立由班组、施工队、项目部组成的三级质量保证体系,定期召开质量分析会,对存在的问题全面分析,找出原因,制定对策,确保质量。施工过程中严格遵守监理程序,服从监理工程师各项指令。

1、加强技术管理:认真贯彻各项目技术管理制度、开工前落实各项人员岗位责任制,做好技术交底,使每个施工人员做到对工程的总体要求明确,对本岗位职责、质量和技术要求有深刻了解。

2、实行项目技术负责人质量负责制,建立完善的质量管理和质量信息网络,项目技术负责领导下的质量管理小组,具有检查、监督、指导各班组、各工序的工作质量和工作成果的权利,并将检查结果上报项目经理部,做为考核班组和个人的依据并与经济收入挂钩。

3、对影响成果质量的关键工序明确责任人,前一道工序对下道工序负责,凡不符合质量标准的前道工序不纠正不得转入下道工序。

4、实行质检员24小时跟班作业制度,严格掌握各工序的质量标准,防患于未然。

5、认真做好各种原始记录施工日记,做到准确、及时、齐全,整理汇总反馈信息,进一步指导施工。

6.3.2. 组织保证措施

(1)项目经理为工程质量第一责任人,对质量安全负全责;

(2)项目经理部的所有施工人员在项目经理的统一指挥下,分工协作负责督促检查各工种施工质量;

(3)施工人员组织情况及具体分工如下表:

(4)整个工程施工,均应在监理工程师的监督下进行。

第六章 安全保证措施

1. 安全管理体系

建立健全安全生产保证体系,贯彻国家有关安全生产和劳动保护方面的法律、法规,研究项目安全生产工作,发现问题,及时处理解决。逐级签订安全施工合同,使各级明确

自己的安全目标,达到全面管理,消除事故隐患,实现安全生产的目的。

2. 安全管理制度

1、坚持预防为主的原则,防患于未然,现场成立安全生产领导小组。设专职安全员,建立安全生产管理网络,经常检查督促安全生产,每周两次安全例会,强化安全意识,落实安全措施,做到人人关心生产重视安全。

2、进入现场施工人员均必须穿戴劳保用品,配戴安全帽,遵守建筑安全操作规程和有关规定,各安全口挂设警示牌。

3、所有机械操作人员均应有操作合格证,设备要经常检查,不可带病运转使用。

4、现场24小时有专职电工值班,电器设备均要安装漏电保护器。

5、严禁坑边大量堆放砖,基坑边严格按要求控制荷载,避免堆砖过高导致基坑塌方或砖垮塌。

6、加强安全监控措施,必要时采取相应的应急措施,加以补救。

3. 安全技术措施

(1)根据本工程场地、机械施工、配合工种多的特点,制定安全措施,建立安全责任制并定期开展安全活动。

(2)各种机械,各工种要遵守各自的安全操作规程.注意相互间的安全距离,施工机械不得撞击排水管、测量基点等。

(4)现场出入口要设安全岗,配备专人指挥运砖、砂浆车辆,汽车司机要遵守交通法规和有关规定,按指定路线行驶,按指定地点卸砖、砂浆。

(5) 要遵守本地区,本工地安全、保卫、消防、市容,环卫,交通等管理规定。要加强工人的管理教育,工人要有“三证”,做到合法用工,上岗前要进行安全交底和安全教育。

4. 职工安全生产管理措施

(l)建立健全安全机构,配备安全管理人员。公司、项目部二级分别设立安全领导小组、安全管理小组,设置公司安全监督部、项目施工安全组作业专职管理部门,各级都配备足够的符合要求的安全管理人员.实行专管与群管相结合的管理体系,横向到边,纵向到底,形成管理网络。

(2)建立以安全生产责任制为核心的各项安全管理制度。主要包括各级各类人员的安全生产责任制、安全生产目标管理制度、安全检查制度、安全教育制度、安全技术措施计划制度、安全交底制度、特种作业人员管理制度、安全验收制度、班组安全活动制度、事故报告与调查处理制度、安全奖罚制度等。安全生产责任目标层层分解。落实到人,严格考核结果与经济挂钩。

(3)强化安全教育,加强人员管理。加强现场管理人员的安全意识,使每一个管理人员做到关心安全并在实际的管理工作中坚持做到安全第一,认真履行职责、严格执行三级安全教育和安全交底制度,未经教育和交底的人员不准上岗作业。坚持经常性教育,教育职工由“要我安全’变为“我要安全”。特种作业人员必须持有效操作证上岗。严格人员管理,规范用工,严肃查处违章操作和违反劳动纪律的行为,使员工做到不伤害自己、不伤害他人、不被他人伤害。

(4)严格监督检查,消除事故隐患。公司每季度定期检查,平时抽查;项目部每月定期检查,平时抽查;项目经理和安全员坚持每日安全巡视,对检查发现的事故隐患,定人、定期进行处理。

(5)对全体施工员工进行安全教育,牢固树立“生产必须安全,安全为了生产”及“安全第一、预防为主、综合治理”的思想。

(6)安全员必须经常在现场检查监督,施工人员必须服从安全员的管理。经常开展安全活动,杜绝各种事故发生。

(7)进入现场必须戴安全帽,禁止赤脚及穿拖鞋。

(8)做好设备保养,防护设备安全可靠,机械运转正常。

(9)电器系统必须保持干燥,装好漏电开关,定期检修。经常检查电线、电路情况,如发现线路老化、破损等应及时更换。


相关文章

  • 砖胎膜专项施工方案 1
  • 砖胎模专项施工方案 湖北全洲扬子江建设工程有限公司 编制: 审核: 审批: 目录 封面 .................................................. 1 目录 .................... ...查看


  • 承台砖胎膜专项方案
  • 东方国际社区二期29#楼 (含地下室) 砖胎模施工方案 编 制 人: 审 核 人: 审 批 人: 编制时间: 二0 年 月 XX建设工程开发有限责任公司 目 录 一.工程概况 ................................ ...查看


  • 基础砖胎膜施工方案1
  • 合肥滨湖竹园廉租房工程 基 础 砖 模 施 工 方 案 编制: 审核: 审批: 安徽水安建设集团股份有限公司 二O一三年二月 一. 工程概况: 本工程地下室占地面积3481m2,基础为桩承载筏板基础,共有工程桩206根,桩承台较多,地下室底 ...查看


  • 地基基础预制板模板.砖胎膜施工方案
  • 预制板施工方案 目 录 1.编制依据......................................................... 1 2.工程概况.................................... ...查看


  • 基础砖胎膜docx
  • 技 术 交 底 记 录 表 C2-1 工程名称 施工单位 交底提要 河北廊坊大城国际 3#.4#楼 北京轩宇立坤建筑工程有限公司大城分 公司 编 号 2015-1-18 地基与基础工程 交底日期 分项工程名称 地下室砖胎膜施工 交底内容: ...查看


  • 12砖胎膜施工方案----1
  • 砖胎模专项施工方案 一.工程概况 1.工程名称:苏地2010-B-51号地块建设工程(商服用房)-花样城 2.工程地点:珠江路西侧.苏福路北侧.沈巷路东侧 3.建设单位:苏州东和置业有限公司 4.设计单位:苏州市建筑设计研究院有限责任公司 ...查看


  • "4.28"脚手架坍塌事故调查报告
  • 东营市东营区中石化胜利油建工程有限公司液化气球罐内操作平台"4.28"较大坍塌事故调查报告 2014年4月28日7:05分,中石化胜利油建工程有限公司(以下简称胜利油建公司)在地处东营市东营区的山东万通集团东营海欣仓储有 ...查看


  • 投资额审计报告
  • 政府投资项目审计和土地评审报告格式-- ? <工程结算审计报告> ? <建设项目竣工决算审计报告> ? <审计决定书> ? <跟踪审计阶段性报告>及<通报> ? <土地储备支 ...查看


  • 2013年一级市政实务考试真题及答案
  • 2013年一级建造师考试<市政实务>真题及答案 1.关于降噪排水路面说法,正确的是(A.磨耗层采用SMA 混合料B.上面层采用OGFC 沥青混合料C.中面层采用间断级配沥青混合料D.底面层采用间断级配混合料[答案]B [解析]今 ...查看


热门内容