中国移动苏州分公司驻地网接入工程验收规范
(试行)
目录
1、总
2、标 则 . .................................................................................................................. 2 签 . .................................................................................................................. 2
2.1、设备标签 . ....................................................................................................... 2
2.2、线缆标签 . ....................................................................................................... 3
2.3、光缆标签 . ....................................................................................................... 3
2.4、户线标签 . ....................................................................................................... 4
2.5、资产标签: . ................................................................................................... 4
3、小区机房、楼道箱 . ............................................................................................... 5
3.1、光缆接地 . ....................................................................................................... 5
3.2、孔洞封堵 . ....................................................................................................... 5
3.3、线缆布放 . ....................................................................................................... 5
3.4、设备安装 . ....................................................................................................... 5
3.5、设备供电 . ....................................................................................................... 6
3.6、设备接地 . ....................................................................................................... 6
4、室外接入 . ............................................................................................................... 6
4.1、光缆路由: . ................................................................................................... 6
4.2、光缆布放 . ....................................................................................................... 6
4.3、户线布放 . ....................................................................................................... 6
5、资 料 ................................................................................................................. 7
5.1、资管系统 . ....................................................................................................... 7
5.2、图文资料 . ....................................................................................................... 7
5.3、资源系统 . ....................................................................................................... 7
6、其他 . ....................................................................................................................... 7
1、总 则
1) 本验收规范适用于驻地网接入工程验收。
2) 工程施工所用的器材程式、规格、质量等均应符合苏州移动公司提供标准和
批准的工程设计文件规定。
3) 本规范未列入的施工标准应按设计文件相关规定办理,如设计文件也未规
定,可由建设单位、设计单位、施工单位共同商定补充规定。
4) 工程验收必须严格执行本规范的规定,加强质量检查工作,确保工程质量。
2、标 签
2.1、设备标签
要求标准统一,字迹清晰可辨,建议使用标签打印机。
设备标签上必需填写新制定的统一设备码,采用统一的格式:地点码 - 产品业务编码 - 序列码。一个标准的设备编码例如:SZS10001-C001-01。
地点码为3位大写英文+5位阿拉伯数字,机房内的设备采用机房地点码;地点码前三位标识:
SZS 苏州市区
SZK 昆山
SZT 太仓
SZW 吴江
SZZ 张家港
SZC 常熟
该设备中出现的地点码均和EAM 中出现的地点码完全一致,保证了地点标识上的统一(如以后EAM 对地点码进行调整升位,该处地点码将按同样需求进行调整升位)。
产品业务编码为1位大写英文+3位阿拉伯数字,1位英文代表该设备所属的专业,3位阿拉伯数字代表该设备的厂家、承载的业务种类等等,具体意义参照产品业务编码表。
序列码为2位阿拉伯数字,代表该设备在该地点码下同型设备的区分,从01
开始。
2.2、线缆标签
要求标准统一,字迹清晰可辨,建议使用标签打印机。
一对一连接两端设备的线缆标签标识方法:线缆标签需采用可两面填写的标签,一面填写“TO ”+对端的设备编码,一面填写连接对端设备的端口号(适用于对端设备具有多端口的情况),线缆标签需贴绑在接近末端的线缆上,应贴绑牢固,不易脱落。
一对多连接的线缆标签标识方法:一这端无需贴标签,但多头的每端均需贴标签,一面填写“TO ”+对端的设备编码,一面填写连接对端设备的端口号;也可以在分叉前填写“TO ”+对端的设备编码,而在每个分叉后的端线上贴标签填写对端设备的端口号。
2.3、光缆标签
2.3.1、光缆挂牌
需用铭牌挂在光缆醒目位置。光缆名格式:“M-N 光缆”+“光缆芯数”+“序号”,命名规则与管线系统中的基本一致(即M/N要求带区域,M 、N 顺序:不同级别的M>N的, 同级别的M 的拼音顺序先于N 的,管线系统中不用带光缆芯数) 。
2.3.2、尾纤标签
要求标准统一,字迹清晰可辨,建议使用标签打印机。
设备端口标签格式:传输系统/传输设备网元-槽位-端口,如:太仓华为
G9.4接入网/139-板桥-2-1;光缆纤芯端口标签格式:M-N 的X 芯光缆/纤芯序号;光缆纤芯和设备电端口的成端标签可以按规律集成张贴;尾纤标签格式:源端ODF 端口至宿端ODF 端口+源端设备端口至宿端设备端口。共有设备-设备、设备-ODF 、ODF-ODF 三类,如设备-ODF :02F-01-03-05-06-03.04, 31-沙溪-1-1---26-老闸-2-1; ODF-ODF(沙溪-老闸经双泾转接时双泾的尾纤标签) :02F-01-01-01-02-03.04---02F-01-03-05-06-03.04, 31-沙溪
-1-1---26-老闸-2-1。
2.3.3、DDF&ODF列、架及ODF 单元标签
要求标准统一,字迹清晰可辨,建议使用标签打印机。
DDF&ODF列架标签格式:楼层-第几列-此列第几架;单元标签格式:楼
层-第几列-此列第几架-此架第几单元;端口标签格式:楼层-第几列-此列第几架-此架第几单元-此单元第几端口。光缆未成端等原因的零星纤芯标签贴在纤芯接头处, 且单元号定为99,单元行号定为01,端口号按序递增。格式:光缆名纤芯号/ODF标签。ODF 标签:楼层-第几列-此列第几架-此架第几单元-此单元第几行-此行第几端口, 如02F-01-03-05-06-01(未成端ODF 标签,如02F-01-03-99-01-01)
2.4、户线标签
要求标准统一,字迹清晰可辨,建议使用标签打印机。
户线电缆缆标签需两端粘贴,靠近用户端的填写“TO ”+对端的设备编码+端口号,靠近设备端的填写“TO ”+用户单元及房间号。线缆标签需贴绑在接近末端的线缆上,应贴绑牢固,不易脱落。
2.5、资产标签:
8口(含8口)以内的ONU 不需要资产标签;8口以上(不含8口)ONU 、OLT 、PBX 交换机、路由器、数据交换机、SDH 设备、2米以上机柜、蓄电池、UPS 需要资产标签;
应使用中国移动EAM 规范标签,标签清晰可读,可扫描;资产型号准确并按照资产型号字典规范进行命名。现场验证资产是否已进入EAM 系统,并且状态为“在建工程”,资产的父资产、所属地点、业务系统等信息与现场正确。
3、小区机房、楼道箱
3.1、光缆接地
光缆加强芯和金属外护层在机房和用户终端箱内均需接地。进入机房的光缆加强芯接在机房的室外接地排上,严禁将光缆加强芯乱接、接在机柜外壳上或接在机柜的设备接地上。
3.2、孔洞封堵
光缆、电缆进出小区机房,如需穿过孔洞,则需对穿通后的孔洞进行密封处理,密封需采用专用防火泥进行封堵。
3.3、线缆布放
机房内的线缆布放应遵照线缆布放施工规范,弱电、强电、光缆、馈线均需分开布放,尽量减少交叉情况发生。走线架及立柱上的线缆每1-2米必须进行绑扎固定,机柜内的线缆需走机柜走线槽,电源线和弱电、光纤需分开布放,如机柜无走线槽,则线缆需分类绑扎,固定在机柜相应的位置,机柜内需每30-40公分进行绑扎固定。
机柜内外均禁止飞线,禁止直接从机柜前后或侧门引线进出。
布放的光缆和户线都必须符合设计要求,并按照色谱编排顺序进行成端。
3.4、设备安装
设备均不允许直接放置在地上,也不允许绑扎在走线架上,需安放在机柜(楼道箱)内。安置在机柜(楼道箱)内的设备,如是标准尺寸设备,则需用螺丝直接固定,如是非标准尺寸设备,则需有相应的固定措施。
楼道箱的安装位置结合设计要求与实际情况,安装牢固稳定,同一小区的楼道箱应配置统一钥匙。
光缆终端盒必须固定,光缆终端盒接口部分必须朝下安装。
入网设备的网管数据正常,可远程监控。设备交接时工程部门需消除一切异常告警,验收人员需检查设备的告警功能是否正常(声光告警功能),可通过断纤、断线、环路测试等方法进行简单的告警功能测试。楼道箱内设备告警应该设
置在无声状态。
3.5、设备供电
机房内设备应选择直流设备,并有后备电源,不得采用临时电或墙壁电。 楼道箱的设备用电需有相应的用电协议,如工程安装时只安装宽带接入设备,可采用交流设备,根据用户情况可不配置后备电源,如安装宽带和语音接入设备,则需有后备电源。
3.6、设备接地
机房内设备接地需接入机房的设备接地排,楼道箱内设备接地则根据实际接地条件进行接地,但不允许将设备接地接入交流电的地线和零线。
4、室外接入
4.1、光缆路由:
不得随意借用电信、网通、联通、有线、供电的传输管道和杆路,包括雨水及污水管道,如流程系统中审核通过的借用不在统计范围内。只要存在租用其他运营商管道或杆路的情况,请将详细路段、长度、位置等信息在验收打分表的“扣分说明”中注明留底。
4.2、光缆布放
敷设后的光缆应平直、无扭伤、无明显刮痕和损伤。光缆预留、接头余留应按照设计要求预留。在每个人孔及架空光缆起始、接头处内应及时挂光缆标牌。引上管的材质、规格、安装地点应符合设计要求。光缆接续应符合衰耗要求,并做好标记,光缆接头盒的封装按工艺要求进行。
4.3、户线布放
敷设后的户线应平直、无严重扭伤、无明显刮痕和损伤,从设备至用户门口无接头,户线走向合理,横平竖直,且固定良好。固定一般用绝缘卡钉,同一方
向敷设2条以上,须分设卡钉,多条布线考虑用线槽。尽量避开电力线,如需交叉需加以保护。
5、资 料
5.1、资管系统
进入管线系统中查阅是否已规范、准确录入管线资料和成端信息;租用管道、杆路情况与图纸所列是否一致齐全。室外接入光缆的实际施工路由,与管线内敷设路由一致。
5.2、图文资料
现场检查图纸资料与验收现场是否一致。
另检查所提供资源表格与现场是否一致。目前提供资料表格主要为“EPON 一级分光用户登记表”;“小区ONU 设备采集表.xls ”;”小区基本信息表采集表.xls ”;“小区宽带业务覆盖地址采集表.xls ”;
5.3、资源系统
进入资源系统检查是否已按要求录入待验收的覆盖标准地址以及已安装的接入设备(主要为ONU 和楼道交换机)。
6、其他
1) 本验收规范与“驻地网接入工程验收表.xls ”同时使用,作为驻地网接入工程验收表的详细解释和规范基础。
2) 每张验收表适用于一个驻地网接入项目的全套验收。
3) 每张验收表基准合格线为80分,同时需由驻地网代维验收代表确认是否可以通过验收且具备装机条件,验收结果将记入集团工程一次通过率考核。
4) 如验收中发现验收表中提及的“一票否决”项目,则代维有权终止验收,验收结果将记入驻地网工程一次通过率考核。
5) 施工队如对某项扣分或验收结果有异议,可提请工程建设部针对该扣分项目
进行解释,并建议免考核及无需整改,由网络部与工程建设部协商一致后可对该项扣分进行调整。
6) 工程部应在收到验收打分表后针对每项扣分限时进行整改,完成后反馈至网络部。如需进行二次验收,验收结果将记入集团工程二次通过率考核。
7) 验收规范版本历史:
2009年6月8日,驻地网接入验收规范V1.0版 由姜峰整理
2009年6月11日,驻地网接入验收规范V1.1版 由工程建设部、市县各响应组组长讨论后整理
中国移动苏州分公司驻地网接入工程验收规范
(试行)
目录
1、总
2、标 则 . .................................................................................................................. 2 签 . .................................................................................................................. 2
2.1、设备标签 . ....................................................................................................... 2
2.2、线缆标签 . ....................................................................................................... 3
2.3、光缆标签 . ....................................................................................................... 3
2.4、户线标签 . ....................................................................................................... 4
2.5、资产标签: . ................................................................................................... 4
3、小区机房、楼道箱 . ............................................................................................... 5
3.1、光缆接地 . ....................................................................................................... 5
3.2、孔洞封堵 . ....................................................................................................... 5
3.3、线缆布放 . ....................................................................................................... 5
3.4、设备安装 . ....................................................................................................... 5
3.5、设备供电 . ....................................................................................................... 6
3.6、设备接地 . ....................................................................................................... 6
4、室外接入 . ............................................................................................................... 6
4.1、光缆路由: . ................................................................................................... 6
4.2、光缆布放 . ....................................................................................................... 6
4.3、户线布放 . ....................................................................................................... 6
5、资 料 ................................................................................................................. 7
5.1、资管系统 . ....................................................................................................... 7
5.2、图文资料 . ....................................................................................................... 7
5.3、资源系统 . ....................................................................................................... 7
6、其他 . ....................................................................................................................... 7
1、总 则
1) 本验收规范适用于驻地网接入工程验收。
2) 工程施工所用的器材程式、规格、质量等均应符合苏州移动公司提供标准和
批准的工程设计文件规定。
3) 本规范未列入的施工标准应按设计文件相关规定办理,如设计文件也未规
定,可由建设单位、设计单位、施工单位共同商定补充规定。
4) 工程验收必须严格执行本规范的规定,加强质量检查工作,确保工程质量。
2、标 签
2.1、设备标签
要求标准统一,字迹清晰可辨,建议使用标签打印机。
设备标签上必需填写新制定的统一设备码,采用统一的格式:地点码 - 产品业务编码 - 序列码。一个标准的设备编码例如:SZS10001-C001-01。
地点码为3位大写英文+5位阿拉伯数字,机房内的设备采用机房地点码;地点码前三位标识:
SZS 苏州市区
SZK 昆山
SZT 太仓
SZW 吴江
SZZ 张家港
SZC 常熟
该设备中出现的地点码均和EAM 中出现的地点码完全一致,保证了地点标识上的统一(如以后EAM 对地点码进行调整升位,该处地点码将按同样需求进行调整升位)。
产品业务编码为1位大写英文+3位阿拉伯数字,1位英文代表该设备所属的专业,3位阿拉伯数字代表该设备的厂家、承载的业务种类等等,具体意义参照产品业务编码表。
序列码为2位阿拉伯数字,代表该设备在该地点码下同型设备的区分,从01
开始。
2.2、线缆标签
要求标准统一,字迹清晰可辨,建议使用标签打印机。
一对一连接两端设备的线缆标签标识方法:线缆标签需采用可两面填写的标签,一面填写“TO ”+对端的设备编码,一面填写连接对端设备的端口号(适用于对端设备具有多端口的情况),线缆标签需贴绑在接近末端的线缆上,应贴绑牢固,不易脱落。
一对多连接的线缆标签标识方法:一这端无需贴标签,但多头的每端均需贴标签,一面填写“TO ”+对端的设备编码,一面填写连接对端设备的端口号;也可以在分叉前填写“TO ”+对端的设备编码,而在每个分叉后的端线上贴标签填写对端设备的端口号。
2.3、光缆标签
2.3.1、光缆挂牌
需用铭牌挂在光缆醒目位置。光缆名格式:“M-N 光缆”+“光缆芯数”+“序号”,命名规则与管线系统中的基本一致(即M/N要求带区域,M 、N 顺序:不同级别的M>N的, 同级别的M 的拼音顺序先于N 的,管线系统中不用带光缆芯数) 。
2.3.2、尾纤标签
要求标准统一,字迹清晰可辨,建议使用标签打印机。
设备端口标签格式:传输系统/传输设备网元-槽位-端口,如:太仓华为
G9.4接入网/139-板桥-2-1;光缆纤芯端口标签格式:M-N 的X 芯光缆/纤芯序号;光缆纤芯和设备电端口的成端标签可以按规律集成张贴;尾纤标签格式:源端ODF 端口至宿端ODF 端口+源端设备端口至宿端设备端口。共有设备-设备、设备-ODF 、ODF-ODF 三类,如设备-ODF :02F-01-03-05-06-03.04, 31-沙溪-1-1---26-老闸-2-1; ODF-ODF(沙溪-老闸经双泾转接时双泾的尾纤标签) :02F-01-01-01-02-03.04---02F-01-03-05-06-03.04, 31-沙溪
-1-1---26-老闸-2-1。
2.3.3、DDF&ODF列、架及ODF 单元标签
要求标准统一,字迹清晰可辨,建议使用标签打印机。
DDF&ODF列架标签格式:楼层-第几列-此列第几架;单元标签格式:楼
层-第几列-此列第几架-此架第几单元;端口标签格式:楼层-第几列-此列第几架-此架第几单元-此单元第几端口。光缆未成端等原因的零星纤芯标签贴在纤芯接头处, 且单元号定为99,单元行号定为01,端口号按序递增。格式:光缆名纤芯号/ODF标签。ODF 标签:楼层-第几列-此列第几架-此架第几单元-此单元第几行-此行第几端口, 如02F-01-03-05-06-01(未成端ODF 标签,如02F-01-03-99-01-01)
2.4、户线标签
要求标准统一,字迹清晰可辨,建议使用标签打印机。
户线电缆缆标签需两端粘贴,靠近用户端的填写“TO ”+对端的设备编码+端口号,靠近设备端的填写“TO ”+用户单元及房间号。线缆标签需贴绑在接近末端的线缆上,应贴绑牢固,不易脱落。
2.5、资产标签:
8口(含8口)以内的ONU 不需要资产标签;8口以上(不含8口)ONU 、OLT 、PBX 交换机、路由器、数据交换机、SDH 设备、2米以上机柜、蓄电池、UPS 需要资产标签;
应使用中国移动EAM 规范标签,标签清晰可读,可扫描;资产型号准确并按照资产型号字典规范进行命名。现场验证资产是否已进入EAM 系统,并且状态为“在建工程”,资产的父资产、所属地点、业务系统等信息与现场正确。
3、小区机房、楼道箱
3.1、光缆接地
光缆加强芯和金属外护层在机房和用户终端箱内均需接地。进入机房的光缆加强芯接在机房的室外接地排上,严禁将光缆加强芯乱接、接在机柜外壳上或接在机柜的设备接地上。
3.2、孔洞封堵
光缆、电缆进出小区机房,如需穿过孔洞,则需对穿通后的孔洞进行密封处理,密封需采用专用防火泥进行封堵。
3.3、线缆布放
机房内的线缆布放应遵照线缆布放施工规范,弱电、强电、光缆、馈线均需分开布放,尽量减少交叉情况发生。走线架及立柱上的线缆每1-2米必须进行绑扎固定,机柜内的线缆需走机柜走线槽,电源线和弱电、光纤需分开布放,如机柜无走线槽,则线缆需分类绑扎,固定在机柜相应的位置,机柜内需每30-40公分进行绑扎固定。
机柜内外均禁止飞线,禁止直接从机柜前后或侧门引线进出。
布放的光缆和户线都必须符合设计要求,并按照色谱编排顺序进行成端。
3.4、设备安装
设备均不允许直接放置在地上,也不允许绑扎在走线架上,需安放在机柜(楼道箱)内。安置在机柜(楼道箱)内的设备,如是标准尺寸设备,则需用螺丝直接固定,如是非标准尺寸设备,则需有相应的固定措施。
楼道箱的安装位置结合设计要求与实际情况,安装牢固稳定,同一小区的楼道箱应配置统一钥匙。
光缆终端盒必须固定,光缆终端盒接口部分必须朝下安装。
入网设备的网管数据正常,可远程监控。设备交接时工程部门需消除一切异常告警,验收人员需检查设备的告警功能是否正常(声光告警功能),可通过断纤、断线、环路测试等方法进行简单的告警功能测试。楼道箱内设备告警应该设
置在无声状态。
3.5、设备供电
机房内设备应选择直流设备,并有后备电源,不得采用临时电或墙壁电。 楼道箱的设备用电需有相应的用电协议,如工程安装时只安装宽带接入设备,可采用交流设备,根据用户情况可不配置后备电源,如安装宽带和语音接入设备,则需有后备电源。
3.6、设备接地
机房内设备接地需接入机房的设备接地排,楼道箱内设备接地则根据实际接地条件进行接地,但不允许将设备接地接入交流电的地线和零线。
4、室外接入
4.1、光缆路由:
不得随意借用电信、网通、联通、有线、供电的传输管道和杆路,包括雨水及污水管道,如流程系统中审核通过的借用不在统计范围内。只要存在租用其他运营商管道或杆路的情况,请将详细路段、长度、位置等信息在验收打分表的“扣分说明”中注明留底。
4.2、光缆布放
敷设后的光缆应平直、无扭伤、无明显刮痕和损伤。光缆预留、接头余留应按照设计要求预留。在每个人孔及架空光缆起始、接头处内应及时挂光缆标牌。引上管的材质、规格、安装地点应符合设计要求。光缆接续应符合衰耗要求,并做好标记,光缆接头盒的封装按工艺要求进行。
4.3、户线布放
敷设后的户线应平直、无严重扭伤、无明显刮痕和损伤,从设备至用户门口无接头,户线走向合理,横平竖直,且固定良好。固定一般用绝缘卡钉,同一方
向敷设2条以上,须分设卡钉,多条布线考虑用线槽。尽量避开电力线,如需交叉需加以保护。
5、资 料
5.1、资管系统
进入管线系统中查阅是否已规范、准确录入管线资料和成端信息;租用管道、杆路情况与图纸所列是否一致齐全。室外接入光缆的实际施工路由,与管线内敷设路由一致。
5.2、图文资料
现场检查图纸资料与验收现场是否一致。
另检查所提供资源表格与现场是否一致。目前提供资料表格主要为“EPON 一级分光用户登记表”;“小区ONU 设备采集表.xls ”;”小区基本信息表采集表.xls ”;“小区宽带业务覆盖地址采集表.xls ”;
5.3、资源系统
进入资源系统检查是否已按要求录入待验收的覆盖标准地址以及已安装的接入设备(主要为ONU 和楼道交换机)。
6、其他
1) 本验收规范与“驻地网接入工程验收表.xls ”同时使用,作为驻地网接入工程验收表的详细解释和规范基础。
2) 每张验收表适用于一个驻地网接入项目的全套验收。
3) 每张验收表基准合格线为80分,同时需由驻地网代维验收代表确认是否可以通过验收且具备装机条件,验收结果将记入集团工程一次通过率考核。
4) 如验收中发现验收表中提及的“一票否决”项目,则代维有权终止验收,验收结果将记入驻地网工程一次通过率考核。
5) 施工队如对某项扣分或验收结果有异议,可提请工程建设部针对该扣分项目
进行解释,并建议免考核及无需整改,由网络部与工程建设部协商一致后可对该项扣分进行调整。
6) 工程部应在收到验收打分表后针对每项扣分限时进行整改,完成后反馈至网络部。如需进行二次验收,验收结果将记入集团工程二次通过率考核。
7) 验收规范版本历史:
2009年6月8日,驻地网接入验收规范V1.0版 由姜峰整理
2009年6月11日,驻地网接入验收规范V1.1版 由工程建设部、市县各响应组组长讨论后整理