降水工程施工方案

目 录

1、工程概况····················································· 3

1.1工程基本概况···················································3

1.2 场地地质条件··················································3

1.3 场地水文地质条件··············································4

1.4工程降水施工的目的及任务·······································4

2、编制依据·······················································5

3、工程降水施工方案··············································5 3.1工程降水施工条件分析···········································5

3.2工程降水施工方法的确立·········································6

3.3降水井埋置深度的确定···········································6

3.4工程降水水文地质参数的确定·····································7

3.5基坑涌水量计算·················································8

3.6单井出水能力、降水井数量的确定··································9

3.7降水井平面位置的确定··········································10

3.8基坑内降深值验算··············································11

3.9达到设计降深时间预测··········································11

3.10降水井施工方案···············································12

3.11排水施工方案·················································12

3.12抽水试验、降水运行及水位监测··································13

4、减少工程降水对基坑周边环境影响的技术措施·················15

4.1工程降水对基坑周边环境影响预测及防治措施·······················15

4.2基坑周边环境的监控措施·····································16

4.3确保地基土不受振动的技术措施·······························16

4.4井点降水影响范围内地面及附着物沉降量估算···················17

4.5井点降水影响范围内地面及附着物沉降的防范措施···············18

5、基坑降水工程施工方案总结·································19

6、基坑降水施工组织设计方案···································19

6.1降水施工质量的技术保证措施·································19

6.2施工组织部署和协调管理·····································20

6.3施工技术措施···············································20

6.4施工应急预案···············································21

6.5主要设备材料供应及需要量计划·······························23

6.6质量保证体系及措施·········································24

6.7文明施工与环境保护措施·····································25

7、参考文献 ···················································26

附图:

降水管井点平面布置图 1幅

降水管井构造图 1幅

1、 工程概况

1.1工程基本概况

玫瑰湾二期七标段工程位于哈尔滨市群力新区第六、七大道、齿轮路、融汇

路合围处,七标段包括B8、B9、B10、B11、B12、B13、B15、B16、B17、B43#

楼及地下车库,拟建建筑为地上2层~31层,地下1层。基坑承台底开挖深度-7.0m ,

局部电梯井部位为-8.15m 。根据近3年降水施工经验,每年该区域3月份地下水

稳定水位埋深5.0米左右,春汛马上到来,地下水水位要上涨1.0~2.0米,为了

保证工程基础正常开挖,根据降水规范要求,地下水应降至基础承台底板下-0.50

米。因此施工时要对该拟建建筑采取必要的降排水措施来保证该建筑物基础施工

安全和施工人员的人身安全。工程降水设计时既要考虑到各建筑区单区作业的特

点,同时又要考虑到整体施工特性及高层住宅与其地下车库相连的整体特性,降

水施工时既要考虑到经济节约又要考虑到各作业区交叉作业的因素,同时还要考

虑到雨季地下水水位上涨的因素,本降水施工方案在设计降水井点设置时,已充

分考虑了这些因素,从而为土建施工和建设单位对小区总体施工规划提供有利施

工条件。

1.2场地地质条件

玫瑰湾二期七标段工程其地貌单元为松花江漫滩区,地基土的成因类型为第

四纪冲洪积地层及前第四系沉积地层,主要由松散砂类土组成,分布较有规律,

主要有以下类型地基土:

第(1)层:杂填土,杂色,以粘性土为主,含大量建筑垃圾,局部含耕土。

厚4.08~.4m 。

第(2)层:粉砂,灰色,松散,稍湿~饱和,局部与粘性土互层,0.2~7.2m 。

(2)1粉质粘土,灰色,可塑偏软,中等压缩性,层厚1.2~4.8m 。

(2)2粉质粘土,灰色,软塑,中等压缩性,层厚0.5~5.4m。

第(3)层:细砂,灰色,稍密,稍湿~饱和,局部夹薄层粘性土,层厚1.0~3.9m 。

第(4)层:中砂,灰色,中密,饱和,局部夹薄层粘性土,局部与粘性土互层,

层厚2.0~11.5m 。

(4)1:粉质粘土,灰色,可塑,中等压缩性,层厚1.0~2.0m 。

第(5)层:粉质粘土,灰色,硬塑,中等压缩性,层厚1.0~4.9m 。

第(6)层:粗砂,灰色,中密,饱和,层厚0.6~10.5m ,局部与粘性土互层。

(6)1细砂,灰色,中密,饱和,局部夹薄层粘性土,层厚0.8~1.9m。

(6)2粉质粘土,灰色,可塑,中等压缩性,层厚1.0~4.2m。

(6)3粗砂,灰色,中密,饱和,局部夹薄层粘性土,层厚1.8~4.0m。

第(7)层:粉质粘土,灰色,可塑,中等压缩性,层厚1.5~18.4。

(7)1粉质粘土,灰色,硬塑,中等压缩性,层厚1.0m

(7)2中砂,灰色,中密,饱和,层厚2.0~2.5m,局部夹薄层粘性土。

第(8)层:粗砂,灰色,中密,饱和,层厚1.3~12.2m。

(8)1粉质粘土,灰色,可塑,中等压缩性,层厚0.5~1.5m。

第(9)层:泥岩,灰色,全风化,块状,最大揭露厚度5.m

1.3场地水文地质条件

1)本场地地貌类型属于松花江漫滩,施工现场场地平坦。

2)按照地下水埋藏条件和含水层的状态分类,施工场区地下水的类型属第四

3)纪松散层孔隙潜水,其主要不给来源为大气降水及地表水,水位补给随季节

4)变化而变化,地下水水位呈周期性变化,勘察报告给出的地下水稳定水位为

1.7~8.5

米,绝对高程为113.66~115.9米,主要赋存于细砂,中砂,砾砂地层中。

3) 由于场区水赋存于沙层中,含水层的渗透性和径流条件相对较好,因此

与花江形成良好的补给和排泄关系,据多年水文资料每年7~9月份时为丰水期,

地下水水位升高1.2~1.8m,3~5月份为枯水期,地下水位下降,地下水位年变

幅2米左右。

1.4本工程降水施工目的及任务

本工程基坑开挖深度为-7.0m ,综合上述水文地质条件,为了保证工程基础正常

开挖,根据《建筑与市政降水工程技术规范》,地下水应降至基坑开挖底板-0.5m ,

即-7.5m 以下才能保证基础正常施工。根据本工程的基坑开挖及基础地板结构施

工的要求,本次降水施工摸底及任务:

(1)疏干维护内地层中的自由水,加固基坑外和坑底下的土体,提高坑外土体

抗力,从而减少坑底隆起和维护结构的变形量,降低基坑外地下水对围护结构

的压力。

(2)最大限度减少因基坑开挖及降水对周边环境产生的影响,保证周边建筑物的安全。

(3)增强土壤的固结强度及直立性,有利基坑内开挖时土体的稳定性。

(4)疏干基坑内地下水,方便挖掘机和工人在坑内施工作业。

2. 编制依据

1、《岩土工程勘察报告》

2、《施工设计图》

3、《岩土工程勘察规范》(GB50021-2001)

4、《建筑与市政降水工程技术规范》(JGJ/T111-98)

5、《建筑地基基础设计规范》(GB50007-2002)

6、《建筑基坑支护技术规程》(GB-50007-2002)

7、《供水水文地质勘察规范》(GB50027-2001)

8、《供水管井技术规范》(GB5096-99)

3、工程降水施工方案

3.1、本工程降水施工条件分析

本工程为在松散砂类土地层中进行的深基坑工程,根据已掌握的建筑物特性、

场地工程地质条件及水文地质条件,以及场地地下水分布情况,降低地下水位是

有效保证基础施不可少的手段。

场地地下水为第四纪松散层孔隙潜水,含水层厚度大,水量较丰富。含水层

主要为粉细砂、中砂、砾砂层。

选择适当的水文地质参数,进行合理的降水井点布设,结合周围相邻建筑分

布和结构情况,设计合理的对周边建筑的保护措施。做到即要满足工程降水施工

的要求,又要对工程降水可能的对周边建筑物产生的沉降影响作出预测和防范。

基坑四周设置观测井点,对相邻建筑物附近地下水水位情况进行观测,针对

水位观测信息及时调整降水施工手段(详见降水井点布置图)。

3.2、本工程降水施工方法的确立

本工程为松散砂类土地层中进行的深基坑工程,降低地下水位是必不可少

的。根据本场地降水时间集中、水位降深及排水量较大的特点,明排和轻型井点

的方法,都不能满足基坑开挖及基础施工干作业的要求,根据《建筑与市政降水

工程技术规范》(JGJ/T111-98)只有采用管井点降水方法,才能确保施工时基坑

挖土和封底时的安全,不发生涌水涌砂,保证底板的稳定性,减少对周边环境的

影响。在降排水施工设计上还要充分考虑场地工程条件,选择合理抽水参数,采

用小泵量,密集井群抽水的方法使场地地下水均匀下降,从而减少对周围建筑群

及周边道路因抽水而引起的沉降变形。

3.3、降水井埋置深度的确定

降水井的深度可按下列公式计算:

H=Hw1+Hw2+Hw3+Hw4+Hw5+Hw6

H-降水井深度(m )

H w1-基坑深度(m )

H w2-降水水位距离基坑底要求的深度

H w3-ir 。I 水力坡度1/15r m

H w4-降水期间水位变幅(m )

H w5-井过滤器长度(m )

H w6-沉砂管长度(m )

L ’-过滤器进水部分的长度(m ),过滤器的长度可按6.0米计算,但在工程

实践中,由于实际地层的地质结构不同,为了能够疏干地基土上部的滞水(如淤

泥层和粉土层中上层滞水或夹层水)及控制单井的进水流速,在施工中采用的过

滤管的长度要长于计算长度,通常采用10米长过滤管。

H w =7.0+0.5+(15×1/15)+2.0+6.0+1.0=17.5m≈18.0m

根据《基坑降水手册》及《深基坑设计手册》中降水设计部分的规定,故本

基坑降水井的深度确定为18米。

3.4工程降水水文地质参数的确定

3.4.1含水层参透系数的确定

为达到基坑开挖所需的无水施工要求,井管大部分座落于粉砂、细砂、中砂

层中,设计降水水位在原始静水位以下3.65米,结合细砂和中砂及粗砂的渗透

系数经验值,得出平均渗透系数K=30.0m/d。根据以往工程降水施工经验,渗透

系数K 值变化非常大,实际施工时根据实际抽水试验来确定渗透系数K 值。

3.4.2影响半径的确定

本场地地下水为孔隙潜水,含水层为潜水含水层,降水井为非完整潜水井,

对于潜水井常用库萨金公式:

式中:

R—降水影响半径(m )

S—原地下水水位到井内水位的距离(m )

v

H—降水井处含水层厚度(m )

K—含水层渗透系数(m )

3.5、基坑涌水量计算

基坑形状为不规则形状,可视为面状基坑,故在计算基坑出水量时采用面状

基坑出水量计算公式计算,如下:

(2H-S)S

Q基㏒(1+ R/R0)

Q-基坑出水量

K-渗透系数,取经验渗透K=30.0m/d

H-含水层厚度

R-影响半径,R=213.52m/d

R 0-基坑等效半径, R0π=75.7

Q 基=1.366K(2H-S )S / ㏒(1+R/R0)≈19476.72m 3/d

计算得高层区基坑每日排水量至少为19476.72 m3才能满足工程降水设计水

位降深需要排水量的要求。

3.6井群单井干扰出水能力、降水井数量的确实

3.6.1、单井出水能力计算

根据场地地质及水文地质条件,结合工程降水条件的分析,依据《建筑与市

政降水工程技术规范》(JGJ/T111-98)采用管井点降水方法施工,单井出水量、

单井井内水位降及基坑涌水量应满足以下条件:

①针对地下水流动对基坑地基土的影响,单井出水量不宜过大,不得超过

40.0 m3/h即960.0 m3/d,单井内水位应与稍大于基坑内最大水位降为宜。

②基坑降水运行时总排水量应大于计算的基坑排水量Q 总=nQ单>Q基。

A

③降水井点数量N=1.1×

a 井

计算管井的出水能力时应选择群井抽水位干扰影响最大的降水井来计算

降水井单井出水能力,按下式确定单井出水量:

Q 单=1’d/α,×24

其中:

Q 单-管井出水能力(m 3 /d)

1’-过滤器淹没段长度(m ),1’=6.0m

d-过滤器外径,d=300mm

α,-与含水层渗透系数有关的经验系数,α,=50

Q 单 = 1’d/α,×24

=(6.0×300/50)×24

=864.0 m3 /d

3.6.2、降水井数量的确定

根据下式降水井点数量计算公式可求出降水井数量:

A

N= 1.1a 井

N-降水井数量,眼

A-基坑降水面积,

a 井-单井有效抽水面积

计算得:N=33眼,初步确定降水井的数量为33眼,主要沿施工区四周设置

降水井,阻挡施工区外来地下水及疏干基坑内地下水,在基坑内设置观测井1

眼用于观测基坑内地下水位变化,同时可做降水井使用,井点总数量为34眼

,详见降水井点平面布置图。

单井水量为864.0 m3 /d,可选用额定出量为25 m3 /h、扬程≥26米、电机

功率为5.5KW 的配套水泵,Q 总 = n Q单 = 33×25×24 =19800.00 m3/d> Q基=

19476.72 m3 /d,由上述验算可知满足前述①、②、③条件。

3.7、降水井平面位置的确定

主要沿基坑四周布置降水井点在基坑外设置降水井距基坑外边缘1.0m ,共

布置降水井33眼,基坑内布置1眼观测井(详见降水井点平面布置图)。

3.8、基坑内降深值计算

根据条状基坑潜水井降水水位预测公式可以算出任意一点的水位降深,现对

基坑内中心水位进行预测:

SX 21 R (H2-h 21)

式中:

SX -验算点水位降深(m )

H-潜水含水层厚度(m )

h1-降水井排处的含水层厚度(m )

X-任意点到井排的距离(m )

R-降水影响半径(m )

S中=5.5(m )

经过以上计算中心水位降为5.5米>5.3米,完全满足降水设计要求,能够

保证基坑正常施工。

3.9、达到设计降深时间预测

利用潜水非完整井非稳定流计算公式:

Q 2.25at

ξ0 )

4πKM r2

式中:

s-验算点水位降深(m )

a-压力传导系数

M-潜水含水层厚度(m )

K-渗透系数(m/d)

ξ0-抽水井完整性的阻力系数

r-井的半径(m )

t-达到水位降深s 时所用时间(h )

利用上式可计算出当基坑中心水位降达到5.3米时,需要用时:

t=90(小时),即3天多可将基坑内的地下水位降到基坑底板下0.5米。

由于场地内含有粉质粘土夹层,渗透系数较小,将会使地基土中的地

下水疏干速度减缓,影响达到设计水位降深的时间,可能要推迟一段时间。

3.10、降水井施工方案

3.10.1、降水井的构造

基坑降水采用管井降水法,管井井点具有排水量大、排水效果好、设备简单、

易于维护等特点。施工钻孔孔径600mm ,采用A 300mm 的大口径管井。其构造如

下: 使用双螺旋UPV-C 塑料井管,井管直径为300mm ,采用孔式过滤器,滤水

器外包2层60目尼绒网以防止粉细砂涌入井内,尼绒网外包10目铁网,防止填

滤料时损坏,管底封死,管外填粒径为5~8mm 砾石作为过滤层,地下6.0m 以上

用粘土填充夯实。

3.10.2、降水井的施工方法

降水井管的埋设采用KP-200、KP-100等返循环钻井,使用清水钻井,开口

直径不小于600mm ,终孔直径600mm ,一次成井的方法,埋设井管,可采用空压

机洗井法或泵抽法洗井,应严格检查滤管包网,要求包网缠绕紧密、均匀,滤料

围填要求均匀填充。管井过滤器、滤料围填、钻进等技术要求,均按照进行的国

家标准《供水水文地质勘察规范》(GB50027-2001)与《供水管井技术规范》

(GB50296-99)的规定执行。

3.11、排水施工方案

从基坑抽出的地下水经支排水管道汇入到主排水管道在输入市政排水管线

中,结合水泵流量经计算采用A 110mmPE 塑料给水管做为支排水管,采用A 300mm

螺旋钢管做为主排水管道;采用单井单管的方式排水,基坑下挖时,随时调整支

排水管的位置,便于配合土建施工。排水管应安装控制阀,有利于降水施工及检

修。 管道敷设按照 《城市排水工程规划规范》(GB50318-2000)执行。

3.12、抽水实验、降水运行及水位监测

3.12.1、抽水试验

①降水井开始施工时,先施工两个以上降水井点,进行抽水试验,获取准

确的水文地质参数,利用取得的可靠的参数、参数调整施工方案。同时在基

坑内外及附近施工4个降水井做为观测井点,观测基坑周围浅基建筑地下水

位变化情况,便于调整抽水的数量和速度。

②抽水试验分3个阶段进行,每次水位降深值大于1米,稳定延续时间不小

于24小时,单井抽水量用阀门水表控制流量,逐渐由单井设计最大出水量25m 3/h

及20 m3/h、15 m3/h、10 m3/h来完成Q 、s-t 过程曲线、q=f(s)曲线、Q=f(s)曲

线的绘制并检验参透系数K 值是否与设计值相匹配,从而对施工方案作出适当修

正和调整。

③抽水试验过程中,当水位趋于稳定时采集及时进行水样,送化验室检验,根

据水的含砂量检验结果,对井底防砂过滤网的目数进行必要的调整。

3.12.2、降水运行

①降水井点施工完毕后,应及时铺设井点排水管,接到降水运行通知后,由

远离周边相邻建筑物的降水井点开始起动,逐一启动降水井,坚决杜绝同时起动。

②降水井抽水运行遵循上述原则,即由远离周边相邻建筑物的降水井点开始

起动,逐一启动降水井,并控制对井点同时开启,观察观测井点的水位变化,能

否满足基础施工要求。

③当连续抽水降水液面达到设计降深要求时,降水井的抽水量大于基坑涌水

量时,可视降水运行情况适当关停部分降水井点,也要以对称关停降水井点为原

则。

④当降水运行结束时,关停降水井,逐个关停,每组关停时间间隔不少于5

小时从而使地下水水位缓慢恢复。

⑤井点降水运行时控制水泵的运行量,从而来控制降水深度和强度,减缓降

水速度,均匀出水,使水位缓缓平稳下降,勿使土颗粒带出,降水时要随时注意

抽水的地下水是否有浑浊现象。

3.12.3、水位监测

①降水运行期间做好观测工作,对观测井点进行水位、水量监测,记录及时

整理,绘制水量Q 与时间t 及水位降深S 与时间t 过程曲线图,以便随时获得水

位下降信息。

②根据水位、水量观测记录,及时查明降水过程中的不正常状况,随时调整

补充措施,确保降水深度,满足正常施工要求,保证如期完成任务。

4、减少工程降水对基坑周边环境影响的技术措施。

4.1工程降水对基坑周边环境影响预测及防治措施

4.1.1、工程降水对基坑周边环境影响预测

①基坑开挖边坡是否稳定,是直接影响周边环境的一个重要因素,护壁挡墙

是否能够真正起到防止边坡土体的位移,这些因素都可能会引起周边地面沉降、

塌陷,地下管线开裂,相邻建筑物基础下沉、倾斜等。

②假设开挖边坡稳定的情况下,基坑降水可能引起较大范围内的地下水下

降,从而形成降落漏斗,引起建筑物基础、地面沉降和地基土的扰动,从而对周

边建筑物、道路及各种地下管线产生塌陷、下沉、开裂、倾斜等不良的影响。

4.1.2、工程降水影响基坑周边环境的防治措施

①抽水运行时尽量先启动基坑内的降水井点,减少降水对周边建筑物和地下

构筑物的影响。

②工程降水运行前,围护强必须施工完毕后方可起动降水井运行。

③井点应连续运转,尽量避免间歇和反复抽水,以减小由工程降水引起的地

面沉降。

④在周边建筑物附近设置观察井点,及时掌握周边地下水的变化情况,如开

挖基坑后止水帷幕发生漏水现象,应及时采取补救措施,防止地下水涌入基坑。

4.2、基坑周边环境的监控措施

基坑开挖前应作出系统的开挖监控方案,从基坑边缘以外选取需要保护的建

(构)筑物或地下管网作为监控对象,同时还应对支护结构和相邻建筑的垂直、

水平位移进行监测。建议建设单位选择具有相应专业监测资质的单位对基础施工

中的各个单项施工项目可能对周边环境产生的影响实施监测,对周边相邻建筑、

基坑开挖边坡稳定性、周边道路等实施全程监测。

4.3、确保地基土不受扰动的技术措施

① 提高降水井成井质量,减少抽出的地下水中颗粒数量,做到抽出的地下

水含砂量不大于0.1‰,从而减少地基基础的移动,确保地基土不受扰动。

②控制抽水井出水量Q 、最大允许流速V 、放置虑水管长度L ,对控制抽水

井附近地基土不发生扰动也是至关重要的一个因素。最大允许流速V 是计算虑水

管直径、长度非常重要的参数,地下水抽水流速超过V 值时,就会使含水砂类土

发生扰动,破坏天然地基土的稳定性。

采用下列公式计算V 值:

V=65K (m/d) K-含水层渗透系数,K=30.0m/d

V=6530.0

=176.44 m/d

滤水管的长度可采用下列公式确定:

Q

L πDV

式中:L-滤水管长度(m )

Q-含水层涌水量,Q=864.0 m3/d

D-滤水管外经,D=0.35m

V-最大允许流速,V=176.44m/d

经上述公式计算得L=4.5m,结合前述章节,本工程降水施工中选用抽水泵

量40.0 m3/h,下置滤水管长度6.0m(﹥4.5m), 从而使地下水流速度低于

176.44m/d,对降水施工是非常安全的,能够确保含水砂类土不发生扰动,天然

地基土的稳定性不受影响。

③降水井成井施工时,将滤水管埋设在地面6.0m 以下,围填滤料至地下

6.0m ,地下6.0m 以上采用粘土封井,从而使地下水在地基土的上部垂直下渗,

不产生水平流动,防止粉尘土受地下水水平流动而移动。

4.4、井点降水影响范围内地面及附着物沉降量估算

1 在井点降水过程中假设无大量地基土细颗粒被地下水带走的情况下,井点 ○

降水对环境的影响程度可以忽略不计,相邻建筑周围地面的沉降主要来自基坑开

挖与降水施工双重因素,此时降水对周围地面所产生的沉降量也可用分层总和法

进行计算。根据《岩土工程勘察规范》(GB50021-94)推荐公式计算地面沉降量:

△P ·△H

E

S-降水对周围地面沉降量(mm )

△P-水位变化施加于土层上的平均荷载(KPa )△P=5kPa

△H-降水深度,为降水液面与原始水位面之差(m ),

取最不利点△=3.65m

E-降水深度范围内土层的压缩模量(Mpa )E=5.29Mpa

计算得S=3.45mm

上述沉降量为估算值,只作为参考数据,以实际沉降观测为准。

4.5、井点降水影响范围内地面及附着物沉降的防范措施

4.5.1、降水施工过程中的控制措施

①适当放缓降水漏斗线的坡度。在同样的降水深度前提下,降水漏斗线的

坡度越平缓,影像范围越大,而所产生的不均匀沉降就越小,因而降水影

像区内的地下管线和建筑物受损伤的程度也越小。把滤水管布置在水平向

连续分布的砂性土中可获得较平缓的降水漏斗曲线,从而减少对周围环境

的影响。

② 井点应连续运转,尽量避免间歇和反复抽水。对砂层土层,降水所引起

的沉降量是很小的,然而倘若降水间歇和反复进行,每次降水都会产生沉

降。每次降水的沉降量随着反复次数的增加而减少,逐渐趋向于零,但是

总和沉降量可以累计到一个相当可观的程度,因此,应尽可能避免反复抽

水。

5、基坑降水工程施工方案总结

(1) 降水施工方法采用深井降水方法,降水井深18.0米,渗透系数30.0米/

天,影响半径为213.52米。

(2) 基坑总水量为19476.72米3/天,基坑外总降水井33眼、基坑观测井1

3眼共计34眼;选用额定出水量25m /h、扬程为26米、电机功率为 5.5KW

的井用潜水泵抽水。

(3) 在降水井中选择有代表性的降水井作为观测井,用以观测基坑周围坑的

水位变化。

6、基坑降水施工组织设计方案

6.1降水施工质量的技术保证措施

① 施工前组织技术质量及全体施工人员进行技术交底,严格按照技术规范《建

筑市政降水工程技术规范》(JGJ/T111-98)与降水施工方案进行施工。

② 严格按施工方案进行降水井施工,配合土方开挖的速度安排,分区域、分段

进行施工。 ③ 降水运行中避免间歇和反复抽水,井点抽水工程中连续运转,定时对降水施

工设备进行检测,对水位,水量及水质随时进行检测,发现异常情况一时查

明原因。

④ 随时注意抽出的地下水是否有浑浊现象,随时检测含沙量(允许值为0.1‰),

抽出的水中带走细颗粒不但会增加周围地面的沉降,而且还会是井管堵塞、

井点失效。

⑤ 降水井施工时严格控制成井质量,降水井的质量好坏直接影响到基坑降水的

安全,对关键施工程序、关键施工部位及关键施工材料进行全程技术跟踪和 监督。

6.2施工组织部署和协调管理

① 本降水工程是为配合土建施工的专业施工,目的是保证土建工程的实

施和进度。

②为保证施工总体进度,同时避免降水施工对土建施工的影响,按照总体

安排进度和工序安排进行降水井施工和降水运行,需土方开挖单位及支护

施工单位等密切配合,团结协作。

③与监理单位协调。在施工过程中,严格按照经业主及监理工程师审核的

“施工组织设计”进行专业工程施工的质量管理。接受监理工程师的验收 和检查。

④与建设单位、总包方及各专业施工协调。降水工程需要与总包方及各专

业施工单位密切配合,衔接好每一步工作流程和安排。特别是成井施工完

毕后进行的降水井排水管的安装及联合抽降时,需要土方、建筑施工单位

的大力配合和协作,降水井管需要根据实际情况更改排水通道及拆改,需

要总包方建设单位的大力配合和协调支持。

6.3施工技术措施

(1)、降水井施工方法:①施工工艺具体如下:

←←←

→ 封井

② 井点放线定位:使用经纬仪按照排水设计布置图精确测量放样。

③钻机就位、钻孔:成孔方法采用KP-200、KP-100钻机进行返循环钻井,使

用清水护壁法成孔,开口直径600mm ,终孔直径600mm ,一次成井,钻至设计深

后清孔。

④安装井管与填料:井管安放垂直,滤水管置入有效含水层内,井管采用

U-PVC 双螺旋塑料管,直径为300mm ,采用孔式过滤器,滤水器外包2层60目

尼绒网,尼绒网外包10目的铁网防止尼绒网在填放滤料时损坏。井管与井壁间

回填5~8mm 砾石作滤水层,地下1m 以上用粘土填充夯实。

⑤洗井:井水中含有泥沙、杂物,会增加泵的磨损,减少寿命或损坏电泵,

可采用空压机或活塞洗井,使抽出的井水达到水清砂净后,在安装深井潜水泵。

⑥ 安装抽水设备:安装前检查井管内径、垂直度是否符合要求,潜水泵下入

有效取水层位(本工程降水水泵放置在地面下10m) ,并安放平稳。连接潜水 泵电机电缆及控制电器。

⑦排水管路的安装:根据现场施工情况,选择排水路线,通往就近排水点。排

水管安装控制阀门,便于水泵发生故障时关闭水泵,及时检修。

(2)供电系统安装及安全措施

① 所有降水井泵同时开启的情况下降水运行总用电功率为181.5KW/小时 ,

考虑到基坑深度较大,降水井数较多,建议在基坑两侧各设立2个总电源。线路

途经地段采用架空明敷设方式。控制系统所需各级配电箱均采用正规厂家生产的

并带有漏电保护装置的配电箱。各级配电箱均需编号,家安全护栏,悬挂警示牌,

并做防雨措施。

②为防止在降水期间发生意外停电现象,现场需要有备用电源(建议建设单位

配备发电机或二路供电系统),并配有自动切换装置。

③电缆敷设路径如遇过路或穿越其他建筑物时,须穿厚度为2mm 以上的护电

套管加以保护。

④供、配电系统的电力开关柜、动力配电箱安放牢固稳妥。

⑤为保证降水工程连续运行,需备足10%的用电设备备件,以便及时换修

用电设备。

⑥ 电力开关柜及动力配电箱需要上锁,做好防雨、防雷、防砸等防护

工作。

⑦供、配电系统设有三级保护装置。电力开关柜中设有过流、短路、过热

保护的自动开关。动力配电箱中设有过流、漏电保护自动开关。

(3)降水井的后期处理

降水施工为辅助工程项目,属于临时工程,降水井在完成使命后,应及时采

取必要的措施进行封填,有哈尔滨市水资源管理办公室监督封填。

(4) 井点施工及排水管敷设时间预计为5天,降水运行时间预计从开始降水

运行之日起,至基础土建施工达到±0.00时,即填土回填至地下车库顶板覆土

覆盖完成,以及建筑物本身重量足可以抵御地下水浮力(达到抗浮设计要求)和

后浇带全部施工完成时,在确认后浇带防水层完全不渗水的情况下,降水运行才

可以停止,降水井陆续停止运行,待地下水水位恢复到原始水位确认地下室没有

漏水、渗水、涌水现象后,将降水井中的抽水电泵撤出,排水管道全部拆除,降

水井封填,降水施工竣工。

6.4、施工应急预案

6.4.1、成井预案

施工前要实地调查场地情况,会同建设单位摸清地下构筑物和管线分布走

向情况,作详细标注说明,并得到建设单位确认无误后方可施工。管井成井过程

中一定要避开已有地下构筑物及管道,具体方法为:钻井前先开挖2-3m ,然后

在用2m 铁钎触探,确认地下无管道及可疑物体后方架设砖机成井。成井过程中

随时注意钻进,并及时上报建设单位,协商解决方案。

6.4.2 降排水过程中停电预案

基坑开挖后,基坑降水就不停止,否则会造成严重的基坑事故,因此甲方

在现场一定要保证电供应,现场安装变压器容量要满足施工要求,架设的

主电缆要合理(主电缆线至少要配备两根),防止压降过大而跳闸、线路

发热等。现场要设电工24小时值班,做到有事立即处理解决。建设单位应

配备2台75kw 发电机组为停电、断电的应急电源,以便紧急情况换用。

6.5、主要设备材料供应及需要量计划

主要材料需要量计划

主要施工设备配备

6.6、质量保证体系及措施

6.6.1、质量保证体系

①质量方针:采用先进技术,实施科学管理;建造一流工程,确保客户满意。

②质量目标:工程质量优良。所有检验一次交验合格率100%。

③质量保证体系:项目经理部全体管理人员及施工队将强化质量意识,推行目

标管理负责制,对施工全过程工程质量进行全面与控制,使之质量保证体系延伸

到各施工部位和各项工作之中,通过明确的分工,密切协调与配合,使工程质量

得到有效的控制。

6.6.2、质量保证措施

①建立健全质量控制和质量保证措施

②设置现场工程质量控制机构,配备有经验的技术人员、管理人员和操作人

员。

③定期向质量部提交水位监测报告。

④参加施工各类人员均为经过培训的合格人员,对特殊工艺、特殊工种作业

人员应有经国家授权的有关机构颁发的特殊工艺、特殊工程作业人员操作证书。

⑤加强思想教育,提高全员质量意识,坚决贯彻执行以下的工程质量控制原

则:贯彻执行“每道工序必检”的原则;贯彻执行“每道工序合格100%”

的原则;贯彻执行“项目经理是工程质量第一责任人,施工操作人员是直接

责任人”的原则

⑥建立健全质量管理制度,加强对关键工序的质量控制,严格执行不合格产

品控制程序,对严重有损于质量和重复发生的不合格项以及质量下降趋势的状

况,认真分析、鉴别并查明起因,采取纠正措施,防止重复出现。

⑦ 把好关键部位、关键工序的质量关。管井降水施工中,严格执行“三级

质量检查”制度,即班组自检,项目部复检出现,院质量办专检。

6.7文明施工与环境保护措施

①文明施工;文明的生产环境是建设好工程的前提,项目部制定文明

施工目标,并制定相应规章制度,成立以项目经理为安全第一责任人,项目

副经理为主管责任人的文明施工保证体系。施工前进行文明施工交底,施工中进

行文明施工检查,项目部配备专兼职安全员,负责现场安全文明施工,形成安全

文明生产管理网络。

②安全生产:坚持:“安全第一,预防为主”的方针和“安全为了生产,生产

必须安全”作为施工原则,加强全员文明生产意识教育,努力提高干部职工

的安全素质,落实各级人员安全文明生产职责,建立健全安全文明生产规章制度,

认真做好安全技术交底,落实各项安全技术措施,经常开展安全检查积极整改各 种安全隐患,认真纠“三违”抓整改,真正做到警钟长鸣,常抓不懈,使各种不文明行为和事故苗头消失在萌芽状态。

7、参考文献

(1)《基坑降水手册》

(2)《工程地质手册》

(3)《岩土工程治理手册》

(4)《工程地质手册》

(5)《地基处理手册》

(6)《城市地下水工程与管理手册》

中国建筑工业出版社 中国建筑工业出版社 中国建筑工业出版社 中国建筑工业出版社 中国建筑工业出版社 中国建筑工业出版社

目 录

1、工程概况····················································· 3

1.1工程基本概况···················································3

1.2 场地地质条件··················································3

1.3 场地水文地质条件··············································4

1.4工程降水施工的目的及任务·······································4

2、编制依据·······················································5

3、工程降水施工方案··············································5 3.1工程降水施工条件分析···········································5

3.2工程降水施工方法的确立·········································6

3.3降水井埋置深度的确定···········································6

3.4工程降水水文地质参数的确定·····································7

3.5基坑涌水量计算·················································8

3.6单井出水能力、降水井数量的确定··································9

3.7降水井平面位置的确定··········································10

3.8基坑内降深值验算··············································11

3.9达到设计降深时间预测··········································11

3.10降水井施工方案···············································12

3.11排水施工方案·················································12

3.12抽水试验、降水运行及水位监测··································13

4、减少工程降水对基坑周边环境影响的技术措施·················15

4.1工程降水对基坑周边环境影响预测及防治措施·······················15

4.2基坑周边环境的监控措施·····································16

4.3确保地基土不受振动的技术措施·······························16

4.4井点降水影响范围内地面及附着物沉降量估算···················17

4.5井点降水影响范围内地面及附着物沉降的防范措施···············18

5、基坑降水工程施工方案总结·································19

6、基坑降水施工组织设计方案···································19

6.1降水施工质量的技术保证措施·································19

6.2施工组织部署和协调管理·····································20

6.3施工技术措施···············································20

6.4施工应急预案···············································21

6.5主要设备材料供应及需要量计划·······························23

6.6质量保证体系及措施·········································24

6.7文明施工与环境保护措施·····································25

7、参考文献 ···················································26

附图:

降水管井点平面布置图 1幅

降水管井构造图 1幅

1、 工程概况

1.1工程基本概况

玫瑰湾二期七标段工程位于哈尔滨市群力新区第六、七大道、齿轮路、融汇

路合围处,七标段包括B8、B9、B10、B11、B12、B13、B15、B16、B17、B43#

楼及地下车库,拟建建筑为地上2层~31层,地下1层。基坑承台底开挖深度-7.0m ,

局部电梯井部位为-8.15m 。根据近3年降水施工经验,每年该区域3月份地下水

稳定水位埋深5.0米左右,春汛马上到来,地下水水位要上涨1.0~2.0米,为了

保证工程基础正常开挖,根据降水规范要求,地下水应降至基础承台底板下-0.50

米。因此施工时要对该拟建建筑采取必要的降排水措施来保证该建筑物基础施工

安全和施工人员的人身安全。工程降水设计时既要考虑到各建筑区单区作业的特

点,同时又要考虑到整体施工特性及高层住宅与其地下车库相连的整体特性,降

水施工时既要考虑到经济节约又要考虑到各作业区交叉作业的因素,同时还要考

虑到雨季地下水水位上涨的因素,本降水施工方案在设计降水井点设置时,已充

分考虑了这些因素,从而为土建施工和建设单位对小区总体施工规划提供有利施

工条件。

1.2场地地质条件

玫瑰湾二期七标段工程其地貌单元为松花江漫滩区,地基土的成因类型为第

四纪冲洪积地层及前第四系沉积地层,主要由松散砂类土组成,分布较有规律,

主要有以下类型地基土:

第(1)层:杂填土,杂色,以粘性土为主,含大量建筑垃圾,局部含耕土。

厚4.08~.4m 。

第(2)层:粉砂,灰色,松散,稍湿~饱和,局部与粘性土互层,0.2~7.2m 。

(2)1粉质粘土,灰色,可塑偏软,中等压缩性,层厚1.2~4.8m 。

(2)2粉质粘土,灰色,软塑,中等压缩性,层厚0.5~5.4m。

第(3)层:细砂,灰色,稍密,稍湿~饱和,局部夹薄层粘性土,层厚1.0~3.9m 。

第(4)层:中砂,灰色,中密,饱和,局部夹薄层粘性土,局部与粘性土互层,

层厚2.0~11.5m 。

(4)1:粉质粘土,灰色,可塑,中等压缩性,层厚1.0~2.0m 。

第(5)层:粉质粘土,灰色,硬塑,中等压缩性,层厚1.0~4.9m 。

第(6)层:粗砂,灰色,中密,饱和,层厚0.6~10.5m ,局部与粘性土互层。

(6)1细砂,灰色,中密,饱和,局部夹薄层粘性土,层厚0.8~1.9m。

(6)2粉质粘土,灰色,可塑,中等压缩性,层厚1.0~4.2m。

(6)3粗砂,灰色,中密,饱和,局部夹薄层粘性土,层厚1.8~4.0m。

第(7)层:粉质粘土,灰色,可塑,中等压缩性,层厚1.5~18.4。

(7)1粉质粘土,灰色,硬塑,中等压缩性,层厚1.0m

(7)2中砂,灰色,中密,饱和,层厚2.0~2.5m,局部夹薄层粘性土。

第(8)层:粗砂,灰色,中密,饱和,层厚1.3~12.2m。

(8)1粉质粘土,灰色,可塑,中等压缩性,层厚0.5~1.5m。

第(9)层:泥岩,灰色,全风化,块状,最大揭露厚度5.m

1.3场地水文地质条件

1)本场地地貌类型属于松花江漫滩,施工现场场地平坦。

2)按照地下水埋藏条件和含水层的状态分类,施工场区地下水的类型属第四

3)纪松散层孔隙潜水,其主要不给来源为大气降水及地表水,水位补给随季节

4)变化而变化,地下水水位呈周期性变化,勘察报告给出的地下水稳定水位为

1.7~8.5

米,绝对高程为113.66~115.9米,主要赋存于细砂,中砂,砾砂地层中。

3) 由于场区水赋存于沙层中,含水层的渗透性和径流条件相对较好,因此

与花江形成良好的补给和排泄关系,据多年水文资料每年7~9月份时为丰水期,

地下水水位升高1.2~1.8m,3~5月份为枯水期,地下水位下降,地下水位年变

幅2米左右。

1.4本工程降水施工目的及任务

本工程基坑开挖深度为-7.0m ,综合上述水文地质条件,为了保证工程基础正常

开挖,根据《建筑与市政降水工程技术规范》,地下水应降至基坑开挖底板-0.5m ,

即-7.5m 以下才能保证基础正常施工。根据本工程的基坑开挖及基础地板结构施

工的要求,本次降水施工摸底及任务:

(1)疏干维护内地层中的自由水,加固基坑外和坑底下的土体,提高坑外土体

抗力,从而减少坑底隆起和维护结构的变形量,降低基坑外地下水对围护结构

的压力。

(2)最大限度减少因基坑开挖及降水对周边环境产生的影响,保证周边建筑物的安全。

(3)增强土壤的固结强度及直立性,有利基坑内开挖时土体的稳定性。

(4)疏干基坑内地下水,方便挖掘机和工人在坑内施工作业。

2. 编制依据

1、《岩土工程勘察报告》

2、《施工设计图》

3、《岩土工程勘察规范》(GB50021-2001)

4、《建筑与市政降水工程技术规范》(JGJ/T111-98)

5、《建筑地基基础设计规范》(GB50007-2002)

6、《建筑基坑支护技术规程》(GB-50007-2002)

7、《供水水文地质勘察规范》(GB50027-2001)

8、《供水管井技术规范》(GB5096-99)

3、工程降水施工方案

3.1、本工程降水施工条件分析

本工程为在松散砂类土地层中进行的深基坑工程,根据已掌握的建筑物特性、

场地工程地质条件及水文地质条件,以及场地地下水分布情况,降低地下水位是

有效保证基础施不可少的手段。

场地地下水为第四纪松散层孔隙潜水,含水层厚度大,水量较丰富。含水层

主要为粉细砂、中砂、砾砂层。

选择适当的水文地质参数,进行合理的降水井点布设,结合周围相邻建筑分

布和结构情况,设计合理的对周边建筑的保护措施。做到即要满足工程降水施工

的要求,又要对工程降水可能的对周边建筑物产生的沉降影响作出预测和防范。

基坑四周设置观测井点,对相邻建筑物附近地下水水位情况进行观测,针对

水位观测信息及时调整降水施工手段(详见降水井点布置图)。

3.2、本工程降水施工方法的确立

本工程为松散砂类土地层中进行的深基坑工程,降低地下水位是必不可少

的。根据本场地降水时间集中、水位降深及排水量较大的特点,明排和轻型井点

的方法,都不能满足基坑开挖及基础施工干作业的要求,根据《建筑与市政降水

工程技术规范》(JGJ/T111-98)只有采用管井点降水方法,才能确保施工时基坑

挖土和封底时的安全,不发生涌水涌砂,保证底板的稳定性,减少对周边环境的

影响。在降排水施工设计上还要充分考虑场地工程条件,选择合理抽水参数,采

用小泵量,密集井群抽水的方法使场地地下水均匀下降,从而减少对周围建筑群

及周边道路因抽水而引起的沉降变形。

3.3、降水井埋置深度的确定

降水井的深度可按下列公式计算:

H=Hw1+Hw2+Hw3+Hw4+Hw5+Hw6

H-降水井深度(m )

H w1-基坑深度(m )

H w2-降水水位距离基坑底要求的深度

H w3-ir 。I 水力坡度1/15r m

H w4-降水期间水位变幅(m )

H w5-井过滤器长度(m )

H w6-沉砂管长度(m )

L ’-过滤器进水部分的长度(m ),过滤器的长度可按6.0米计算,但在工程

实践中,由于实际地层的地质结构不同,为了能够疏干地基土上部的滞水(如淤

泥层和粉土层中上层滞水或夹层水)及控制单井的进水流速,在施工中采用的过

滤管的长度要长于计算长度,通常采用10米长过滤管。

H w =7.0+0.5+(15×1/15)+2.0+6.0+1.0=17.5m≈18.0m

根据《基坑降水手册》及《深基坑设计手册》中降水设计部分的规定,故本

基坑降水井的深度确定为18米。

3.4工程降水水文地质参数的确定

3.4.1含水层参透系数的确定

为达到基坑开挖所需的无水施工要求,井管大部分座落于粉砂、细砂、中砂

层中,设计降水水位在原始静水位以下3.65米,结合细砂和中砂及粗砂的渗透

系数经验值,得出平均渗透系数K=30.0m/d。根据以往工程降水施工经验,渗透

系数K 值变化非常大,实际施工时根据实际抽水试验来确定渗透系数K 值。

3.4.2影响半径的确定

本场地地下水为孔隙潜水,含水层为潜水含水层,降水井为非完整潜水井,

对于潜水井常用库萨金公式:

式中:

R—降水影响半径(m )

S—原地下水水位到井内水位的距离(m )

v

H—降水井处含水层厚度(m )

K—含水层渗透系数(m )

3.5、基坑涌水量计算

基坑形状为不规则形状,可视为面状基坑,故在计算基坑出水量时采用面状

基坑出水量计算公式计算,如下:

(2H-S)S

Q基㏒(1+ R/R0)

Q-基坑出水量

K-渗透系数,取经验渗透K=30.0m/d

H-含水层厚度

R-影响半径,R=213.52m/d

R 0-基坑等效半径, R0π=75.7

Q 基=1.366K(2H-S )S / ㏒(1+R/R0)≈19476.72m 3/d

计算得高层区基坑每日排水量至少为19476.72 m3才能满足工程降水设计水

位降深需要排水量的要求。

3.6井群单井干扰出水能力、降水井数量的确实

3.6.1、单井出水能力计算

根据场地地质及水文地质条件,结合工程降水条件的分析,依据《建筑与市

政降水工程技术规范》(JGJ/T111-98)采用管井点降水方法施工,单井出水量、

单井井内水位降及基坑涌水量应满足以下条件:

①针对地下水流动对基坑地基土的影响,单井出水量不宜过大,不得超过

40.0 m3/h即960.0 m3/d,单井内水位应与稍大于基坑内最大水位降为宜。

②基坑降水运行时总排水量应大于计算的基坑排水量Q 总=nQ单>Q基。

A

③降水井点数量N=1.1×

a 井

计算管井的出水能力时应选择群井抽水位干扰影响最大的降水井来计算

降水井单井出水能力,按下式确定单井出水量:

Q 单=1’d/α,×24

其中:

Q 单-管井出水能力(m 3 /d)

1’-过滤器淹没段长度(m ),1’=6.0m

d-过滤器外径,d=300mm

α,-与含水层渗透系数有关的经验系数,α,=50

Q 单 = 1’d/α,×24

=(6.0×300/50)×24

=864.0 m3 /d

3.6.2、降水井数量的确定

根据下式降水井点数量计算公式可求出降水井数量:

A

N= 1.1a 井

N-降水井数量,眼

A-基坑降水面积,

a 井-单井有效抽水面积

计算得:N=33眼,初步确定降水井的数量为33眼,主要沿施工区四周设置

降水井,阻挡施工区外来地下水及疏干基坑内地下水,在基坑内设置观测井1

眼用于观测基坑内地下水位变化,同时可做降水井使用,井点总数量为34眼

,详见降水井点平面布置图。

单井水量为864.0 m3 /d,可选用额定出量为25 m3 /h、扬程≥26米、电机

功率为5.5KW 的配套水泵,Q 总 = n Q单 = 33×25×24 =19800.00 m3/d> Q基=

19476.72 m3 /d,由上述验算可知满足前述①、②、③条件。

3.7、降水井平面位置的确定

主要沿基坑四周布置降水井点在基坑外设置降水井距基坑外边缘1.0m ,共

布置降水井33眼,基坑内布置1眼观测井(详见降水井点平面布置图)。

3.8、基坑内降深值计算

根据条状基坑潜水井降水水位预测公式可以算出任意一点的水位降深,现对

基坑内中心水位进行预测:

SX 21 R (H2-h 21)

式中:

SX -验算点水位降深(m )

H-潜水含水层厚度(m )

h1-降水井排处的含水层厚度(m )

X-任意点到井排的距离(m )

R-降水影响半径(m )

S中=5.5(m )

经过以上计算中心水位降为5.5米>5.3米,完全满足降水设计要求,能够

保证基坑正常施工。

3.9、达到设计降深时间预测

利用潜水非完整井非稳定流计算公式:

Q 2.25at

ξ0 )

4πKM r2

式中:

s-验算点水位降深(m )

a-压力传导系数

M-潜水含水层厚度(m )

K-渗透系数(m/d)

ξ0-抽水井完整性的阻力系数

r-井的半径(m )

t-达到水位降深s 时所用时间(h )

利用上式可计算出当基坑中心水位降达到5.3米时,需要用时:

t=90(小时),即3天多可将基坑内的地下水位降到基坑底板下0.5米。

由于场地内含有粉质粘土夹层,渗透系数较小,将会使地基土中的地

下水疏干速度减缓,影响达到设计水位降深的时间,可能要推迟一段时间。

3.10、降水井施工方案

3.10.1、降水井的构造

基坑降水采用管井降水法,管井井点具有排水量大、排水效果好、设备简单、

易于维护等特点。施工钻孔孔径600mm ,采用A 300mm 的大口径管井。其构造如

下: 使用双螺旋UPV-C 塑料井管,井管直径为300mm ,采用孔式过滤器,滤水

器外包2层60目尼绒网以防止粉细砂涌入井内,尼绒网外包10目铁网,防止填

滤料时损坏,管底封死,管外填粒径为5~8mm 砾石作为过滤层,地下6.0m 以上

用粘土填充夯实。

3.10.2、降水井的施工方法

降水井管的埋设采用KP-200、KP-100等返循环钻井,使用清水钻井,开口

直径不小于600mm ,终孔直径600mm ,一次成井的方法,埋设井管,可采用空压

机洗井法或泵抽法洗井,应严格检查滤管包网,要求包网缠绕紧密、均匀,滤料

围填要求均匀填充。管井过滤器、滤料围填、钻进等技术要求,均按照进行的国

家标准《供水水文地质勘察规范》(GB50027-2001)与《供水管井技术规范》

(GB50296-99)的规定执行。

3.11、排水施工方案

从基坑抽出的地下水经支排水管道汇入到主排水管道在输入市政排水管线

中,结合水泵流量经计算采用A 110mmPE 塑料给水管做为支排水管,采用A 300mm

螺旋钢管做为主排水管道;采用单井单管的方式排水,基坑下挖时,随时调整支

排水管的位置,便于配合土建施工。排水管应安装控制阀,有利于降水施工及检

修。 管道敷设按照 《城市排水工程规划规范》(GB50318-2000)执行。

3.12、抽水实验、降水运行及水位监测

3.12.1、抽水试验

①降水井开始施工时,先施工两个以上降水井点,进行抽水试验,获取准

确的水文地质参数,利用取得的可靠的参数、参数调整施工方案。同时在基

坑内外及附近施工4个降水井做为观测井点,观测基坑周围浅基建筑地下水

位变化情况,便于调整抽水的数量和速度。

②抽水试验分3个阶段进行,每次水位降深值大于1米,稳定延续时间不小

于24小时,单井抽水量用阀门水表控制流量,逐渐由单井设计最大出水量25m 3/h

及20 m3/h、15 m3/h、10 m3/h来完成Q 、s-t 过程曲线、q=f(s)曲线、Q=f(s)曲

线的绘制并检验参透系数K 值是否与设计值相匹配,从而对施工方案作出适当修

正和调整。

③抽水试验过程中,当水位趋于稳定时采集及时进行水样,送化验室检验,根

据水的含砂量检验结果,对井底防砂过滤网的目数进行必要的调整。

3.12.2、降水运行

①降水井点施工完毕后,应及时铺设井点排水管,接到降水运行通知后,由

远离周边相邻建筑物的降水井点开始起动,逐一启动降水井,坚决杜绝同时起动。

②降水井抽水运行遵循上述原则,即由远离周边相邻建筑物的降水井点开始

起动,逐一启动降水井,并控制对井点同时开启,观察观测井点的水位变化,能

否满足基础施工要求。

③当连续抽水降水液面达到设计降深要求时,降水井的抽水量大于基坑涌水

量时,可视降水运行情况适当关停部分降水井点,也要以对称关停降水井点为原

则。

④当降水运行结束时,关停降水井,逐个关停,每组关停时间间隔不少于5

小时从而使地下水水位缓慢恢复。

⑤井点降水运行时控制水泵的运行量,从而来控制降水深度和强度,减缓降

水速度,均匀出水,使水位缓缓平稳下降,勿使土颗粒带出,降水时要随时注意

抽水的地下水是否有浑浊现象。

3.12.3、水位监测

①降水运行期间做好观测工作,对观测井点进行水位、水量监测,记录及时

整理,绘制水量Q 与时间t 及水位降深S 与时间t 过程曲线图,以便随时获得水

位下降信息。

②根据水位、水量观测记录,及时查明降水过程中的不正常状况,随时调整

补充措施,确保降水深度,满足正常施工要求,保证如期完成任务。

4、减少工程降水对基坑周边环境影响的技术措施。

4.1工程降水对基坑周边环境影响预测及防治措施

4.1.1、工程降水对基坑周边环境影响预测

①基坑开挖边坡是否稳定,是直接影响周边环境的一个重要因素,护壁挡墙

是否能够真正起到防止边坡土体的位移,这些因素都可能会引起周边地面沉降、

塌陷,地下管线开裂,相邻建筑物基础下沉、倾斜等。

②假设开挖边坡稳定的情况下,基坑降水可能引起较大范围内的地下水下

降,从而形成降落漏斗,引起建筑物基础、地面沉降和地基土的扰动,从而对周

边建筑物、道路及各种地下管线产生塌陷、下沉、开裂、倾斜等不良的影响。

4.1.2、工程降水影响基坑周边环境的防治措施

①抽水运行时尽量先启动基坑内的降水井点,减少降水对周边建筑物和地下

构筑物的影响。

②工程降水运行前,围护强必须施工完毕后方可起动降水井运行。

③井点应连续运转,尽量避免间歇和反复抽水,以减小由工程降水引起的地

面沉降。

④在周边建筑物附近设置观察井点,及时掌握周边地下水的变化情况,如开

挖基坑后止水帷幕发生漏水现象,应及时采取补救措施,防止地下水涌入基坑。

4.2、基坑周边环境的监控措施

基坑开挖前应作出系统的开挖监控方案,从基坑边缘以外选取需要保护的建

(构)筑物或地下管网作为监控对象,同时还应对支护结构和相邻建筑的垂直、

水平位移进行监测。建议建设单位选择具有相应专业监测资质的单位对基础施工

中的各个单项施工项目可能对周边环境产生的影响实施监测,对周边相邻建筑、

基坑开挖边坡稳定性、周边道路等实施全程监测。

4.3、确保地基土不受扰动的技术措施

① 提高降水井成井质量,减少抽出的地下水中颗粒数量,做到抽出的地下

水含砂量不大于0.1‰,从而减少地基基础的移动,确保地基土不受扰动。

②控制抽水井出水量Q 、最大允许流速V 、放置虑水管长度L ,对控制抽水

井附近地基土不发生扰动也是至关重要的一个因素。最大允许流速V 是计算虑水

管直径、长度非常重要的参数,地下水抽水流速超过V 值时,就会使含水砂类土

发生扰动,破坏天然地基土的稳定性。

采用下列公式计算V 值:

V=65K (m/d) K-含水层渗透系数,K=30.0m/d

V=6530.0

=176.44 m/d

滤水管的长度可采用下列公式确定:

Q

L πDV

式中:L-滤水管长度(m )

Q-含水层涌水量,Q=864.0 m3/d

D-滤水管外经,D=0.35m

V-最大允许流速,V=176.44m/d

经上述公式计算得L=4.5m,结合前述章节,本工程降水施工中选用抽水泵

量40.0 m3/h,下置滤水管长度6.0m(﹥4.5m), 从而使地下水流速度低于

176.44m/d,对降水施工是非常安全的,能够确保含水砂类土不发生扰动,天然

地基土的稳定性不受影响。

③降水井成井施工时,将滤水管埋设在地面6.0m 以下,围填滤料至地下

6.0m ,地下6.0m 以上采用粘土封井,从而使地下水在地基土的上部垂直下渗,

不产生水平流动,防止粉尘土受地下水水平流动而移动。

4.4、井点降水影响范围内地面及附着物沉降量估算

1 在井点降水过程中假设无大量地基土细颗粒被地下水带走的情况下,井点 ○

降水对环境的影响程度可以忽略不计,相邻建筑周围地面的沉降主要来自基坑开

挖与降水施工双重因素,此时降水对周围地面所产生的沉降量也可用分层总和法

进行计算。根据《岩土工程勘察规范》(GB50021-94)推荐公式计算地面沉降量:

△P ·△H

E

S-降水对周围地面沉降量(mm )

△P-水位变化施加于土层上的平均荷载(KPa )△P=5kPa

△H-降水深度,为降水液面与原始水位面之差(m ),

取最不利点△=3.65m

E-降水深度范围内土层的压缩模量(Mpa )E=5.29Mpa

计算得S=3.45mm

上述沉降量为估算值,只作为参考数据,以实际沉降观测为准。

4.5、井点降水影响范围内地面及附着物沉降的防范措施

4.5.1、降水施工过程中的控制措施

①适当放缓降水漏斗线的坡度。在同样的降水深度前提下,降水漏斗线的

坡度越平缓,影像范围越大,而所产生的不均匀沉降就越小,因而降水影

像区内的地下管线和建筑物受损伤的程度也越小。把滤水管布置在水平向

连续分布的砂性土中可获得较平缓的降水漏斗曲线,从而减少对周围环境

的影响。

② 井点应连续运转,尽量避免间歇和反复抽水。对砂层土层,降水所引起

的沉降量是很小的,然而倘若降水间歇和反复进行,每次降水都会产生沉

降。每次降水的沉降量随着反复次数的增加而减少,逐渐趋向于零,但是

总和沉降量可以累计到一个相当可观的程度,因此,应尽可能避免反复抽

水。

5、基坑降水工程施工方案总结

(1) 降水施工方法采用深井降水方法,降水井深18.0米,渗透系数30.0米/

天,影响半径为213.52米。

(2) 基坑总水量为19476.72米3/天,基坑外总降水井33眼、基坑观测井1

3眼共计34眼;选用额定出水量25m /h、扬程为26米、电机功率为 5.5KW

的井用潜水泵抽水。

(3) 在降水井中选择有代表性的降水井作为观测井,用以观测基坑周围坑的

水位变化。

6、基坑降水施工组织设计方案

6.1降水施工质量的技术保证措施

① 施工前组织技术质量及全体施工人员进行技术交底,严格按照技术规范《建

筑市政降水工程技术规范》(JGJ/T111-98)与降水施工方案进行施工。

② 严格按施工方案进行降水井施工,配合土方开挖的速度安排,分区域、分段

进行施工。 ③ 降水运行中避免间歇和反复抽水,井点抽水工程中连续运转,定时对降水施

工设备进行检测,对水位,水量及水质随时进行检测,发现异常情况一时查

明原因。

④ 随时注意抽出的地下水是否有浑浊现象,随时检测含沙量(允许值为0.1‰),

抽出的水中带走细颗粒不但会增加周围地面的沉降,而且还会是井管堵塞、

井点失效。

⑤ 降水井施工时严格控制成井质量,降水井的质量好坏直接影响到基坑降水的

安全,对关键施工程序、关键施工部位及关键施工材料进行全程技术跟踪和 监督。

6.2施工组织部署和协调管理

① 本降水工程是为配合土建施工的专业施工,目的是保证土建工程的实

施和进度。

②为保证施工总体进度,同时避免降水施工对土建施工的影响,按照总体

安排进度和工序安排进行降水井施工和降水运行,需土方开挖单位及支护

施工单位等密切配合,团结协作。

③与监理单位协调。在施工过程中,严格按照经业主及监理工程师审核的

“施工组织设计”进行专业工程施工的质量管理。接受监理工程师的验收 和检查。

④与建设单位、总包方及各专业施工协调。降水工程需要与总包方及各专

业施工单位密切配合,衔接好每一步工作流程和安排。特别是成井施工完

毕后进行的降水井排水管的安装及联合抽降时,需要土方、建筑施工单位

的大力配合和协作,降水井管需要根据实际情况更改排水通道及拆改,需

要总包方建设单位的大力配合和协调支持。

6.3施工技术措施

(1)、降水井施工方法:①施工工艺具体如下:

←←←

→ 封井

② 井点放线定位:使用经纬仪按照排水设计布置图精确测量放样。

③钻机就位、钻孔:成孔方法采用KP-200、KP-100钻机进行返循环钻井,使

用清水护壁法成孔,开口直径600mm ,终孔直径600mm ,一次成井,钻至设计深

后清孔。

④安装井管与填料:井管安放垂直,滤水管置入有效含水层内,井管采用

U-PVC 双螺旋塑料管,直径为300mm ,采用孔式过滤器,滤水器外包2层60目

尼绒网,尼绒网外包10目的铁网防止尼绒网在填放滤料时损坏。井管与井壁间

回填5~8mm 砾石作滤水层,地下1m 以上用粘土填充夯实。

⑤洗井:井水中含有泥沙、杂物,会增加泵的磨损,减少寿命或损坏电泵,

可采用空压机或活塞洗井,使抽出的井水达到水清砂净后,在安装深井潜水泵。

⑥ 安装抽水设备:安装前检查井管内径、垂直度是否符合要求,潜水泵下入

有效取水层位(本工程降水水泵放置在地面下10m) ,并安放平稳。连接潜水 泵电机电缆及控制电器。

⑦排水管路的安装:根据现场施工情况,选择排水路线,通往就近排水点。排

水管安装控制阀门,便于水泵发生故障时关闭水泵,及时检修。

(2)供电系统安装及安全措施

① 所有降水井泵同时开启的情况下降水运行总用电功率为181.5KW/小时 ,

考虑到基坑深度较大,降水井数较多,建议在基坑两侧各设立2个总电源。线路

途经地段采用架空明敷设方式。控制系统所需各级配电箱均采用正规厂家生产的

并带有漏电保护装置的配电箱。各级配电箱均需编号,家安全护栏,悬挂警示牌,

并做防雨措施。

②为防止在降水期间发生意外停电现象,现场需要有备用电源(建议建设单位

配备发电机或二路供电系统),并配有自动切换装置。

③电缆敷设路径如遇过路或穿越其他建筑物时,须穿厚度为2mm 以上的护电

套管加以保护。

④供、配电系统的电力开关柜、动力配电箱安放牢固稳妥。

⑤为保证降水工程连续运行,需备足10%的用电设备备件,以便及时换修

用电设备。

⑥ 电力开关柜及动力配电箱需要上锁,做好防雨、防雷、防砸等防护

工作。

⑦供、配电系统设有三级保护装置。电力开关柜中设有过流、短路、过热

保护的自动开关。动力配电箱中设有过流、漏电保护自动开关。

(3)降水井的后期处理

降水施工为辅助工程项目,属于临时工程,降水井在完成使命后,应及时采

取必要的措施进行封填,有哈尔滨市水资源管理办公室监督封填。

(4) 井点施工及排水管敷设时间预计为5天,降水运行时间预计从开始降水

运行之日起,至基础土建施工达到±0.00时,即填土回填至地下车库顶板覆土

覆盖完成,以及建筑物本身重量足可以抵御地下水浮力(达到抗浮设计要求)和

后浇带全部施工完成时,在确认后浇带防水层完全不渗水的情况下,降水运行才

可以停止,降水井陆续停止运行,待地下水水位恢复到原始水位确认地下室没有

漏水、渗水、涌水现象后,将降水井中的抽水电泵撤出,排水管道全部拆除,降

水井封填,降水施工竣工。

6.4、施工应急预案

6.4.1、成井预案

施工前要实地调查场地情况,会同建设单位摸清地下构筑物和管线分布走

向情况,作详细标注说明,并得到建设单位确认无误后方可施工。管井成井过程

中一定要避开已有地下构筑物及管道,具体方法为:钻井前先开挖2-3m ,然后

在用2m 铁钎触探,确认地下无管道及可疑物体后方架设砖机成井。成井过程中

随时注意钻进,并及时上报建设单位,协商解决方案。

6.4.2 降排水过程中停电预案

基坑开挖后,基坑降水就不停止,否则会造成严重的基坑事故,因此甲方

在现场一定要保证电供应,现场安装变压器容量要满足施工要求,架设的

主电缆要合理(主电缆线至少要配备两根),防止压降过大而跳闸、线路

发热等。现场要设电工24小时值班,做到有事立即处理解决。建设单位应

配备2台75kw 发电机组为停电、断电的应急电源,以便紧急情况换用。

6.5、主要设备材料供应及需要量计划

主要材料需要量计划

主要施工设备配备

6.6、质量保证体系及措施

6.6.1、质量保证体系

①质量方针:采用先进技术,实施科学管理;建造一流工程,确保客户满意。

②质量目标:工程质量优良。所有检验一次交验合格率100%。

③质量保证体系:项目经理部全体管理人员及施工队将强化质量意识,推行目

标管理负责制,对施工全过程工程质量进行全面与控制,使之质量保证体系延伸

到各施工部位和各项工作之中,通过明确的分工,密切协调与配合,使工程质量

得到有效的控制。

6.6.2、质量保证措施

①建立健全质量控制和质量保证措施

②设置现场工程质量控制机构,配备有经验的技术人员、管理人员和操作人

员。

③定期向质量部提交水位监测报告。

④参加施工各类人员均为经过培训的合格人员,对特殊工艺、特殊工种作业

人员应有经国家授权的有关机构颁发的特殊工艺、特殊工程作业人员操作证书。

⑤加强思想教育,提高全员质量意识,坚决贯彻执行以下的工程质量控制原

则:贯彻执行“每道工序必检”的原则;贯彻执行“每道工序合格100%”

的原则;贯彻执行“项目经理是工程质量第一责任人,施工操作人员是直接

责任人”的原则

⑥建立健全质量管理制度,加强对关键工序的质量控制,严格执行不合格产

品控制程序,对严重有损于质量和重复发生的不合格项以及质量下降趋势的状

况,认真分析、鉴别并查明起因,采取纠正措施,防止重复出现。

⑦ 把好关键部位、关键工序的质量关。管井降水施工中,严格执行“三级

质量检查”制度,即班组自检,项目部复检出现,院质量办专检。

6.7文明施工与环境保护措施

①文明施工;文明的生产环境是建设好工程的前提,项目部制定文明

施工目标,并制定相应规章制度,成立以项目经理为安全第一责任人,项目

副经理为主管责任人的文明施工保证体系。施工前进行文明施工交底,施工中进

行文明施工检查,项目部配备专兼职安全员,负责现场安全文明施工,形成安全

文明生产管理网络。

②安全生产:坚持:“安全第一,预防为主”的方针和“安全为了生产,生产

必须安全”作为施工原则,加强全员文明生产意识教育,努力提高干部职工

的安全素质,落实各级人员安全文明生产职责,建立健全安全文明生产规章制度,

认真做好安全技术交底,落实各项安全技术措施,经常开展安全检查积极整改各 种安全隐患,认真纠“三违”抓整改,真正做到警钟长鸣,常抓不懈,使各种不文明行为和事故苗头消失在萌芽状态。

7、参考文献

(1)《基坑降水手册》

(2)《工程地质手册》

(3)《岩土工程治理手册》

(4)《工程地质手册》

(5)《地基处理手册》

(6)《城市地下水工程与管理手册》

中国建筑工业出版社 中国建筑工业出版社 中国建筑工业出版社 中国建筑工业出版社 中国建筑工业出版社 中国建筑工业出版社


相关文章

  • 明沟排水施工方案 1
  • 明沟排水施工方案 2011-7-5 12:30 提问者:孟靖涵 | 浏览次数:2075次 2011-7-5 17:20 满意回答 降水(管井降水与基坑内明沟排水)施工方案 目 录 一.工程概况 二.地质概况 三.降水方案选择 四.井点设计 ...查看


  • 降水排水施工方案
  • 济宁新世纪100社区 (南风花园)工程一标段3#楼 降 水 排 水 施 工 方 案 编制单位:山东诚祥建安集团有限公司 编制时间: 目 录 一.编制依据 ------------------------------------------- ...查看


  • 基坑降水(承压含水层减压降水)施工组织方案及技术保证措施
  • 基坑降水施工组织方案及技术保证措施 1基坑降水分析 本工程降水分为坑内开挖范围内疏干性降水和深层承压含水层减压降水.针对这两类降水分别进行降水设计和现场施工运行. 1.1含水层降水风险分析 根据工程场地工程地质条件与水文地质条件分析,可能引 ...查看


  • 谈城市建设工程地下水控制方法的选择
  • 谈城市建设工程地下水控制方法的选择 中铁第一勘察设计院集团有限公司 李 成 1前言 随着我国城市化进程的加快发展,许多规模超大工程的开工建设,深基坑和人工边坡工程越来越多.在基坑开挖过程中,地下水渗入基坑内,不但会使施工条件恶化,而且会造成 ...查看


  • 高层深基坑降水施工方案.doc
  • 目 录 施工方案调整变更索引表 .................... 错误!未定义书签. 一.基坑降水方案的设计 .................... 错误!未定义书签. 二.抽水方案设计 ..................... ...查看


  • 井点降水方案 1
  • 降水施工方案 工 程 名 称:施工单位(章):技 术 负 责 人:项 目 经 理:项目技术负责人:编 制 人 :审 核 人 :编 制 时 间:吉林 长春 酒店 工程 集团 建设有限公司 表A17-2 会签单 表A17-3 建设工程概况表 降 ...查看


  • 明沟排水施工方案
  • 降水(管井降水与基坑内明沟排水)施工方案 (以B#车间为例) 目录 一. 编制依据 二. 工程概况 三. 地质概况 四. 降水方案选择 五. 明沟排水设计依据 六. 主要施工设备 七. 劳动力计划 八. 主要施工方法 九. 组织保证措施 十 ...查看


  • 井点降水方案
  • 滨 河 新 城 教 育 中 心 工 程 井点降水方案 编 制: 审 批: 审 核: 日 期: 目 录 一.工程概况 .............................................................. ...查看


  • 深井降水方案
  • 锦绣华城三标段 地下人防工程 井点降水施工方案 编制人: 审核人: 批准人: 通州建总集团有限公司 二〇一一年八月六日 一.工程概况 锦绣华城三标段人防工程:属于框架结构; 地下1层:层高:3.4m :总建筑面积:13869平方米,其中1# ...查看


热门内容