毕业论文办公楼框架结构设计

题 目

毕 业 论 文 (设 计)

英文题目 院 系 土木工程与城市建设学院 专 业 姓 名 黄 海 年 级 2010级土A1014 指导教师 戴 嘉 兴

二零一四年六月

摘 要

本工程为华宇办公楼的结构设计,采用混凝土框架结构, 该办公楼为五层钢筋混泥土结构体系,底层层高为3.9m,其它层层高为3.6m,建筑面积约3100m2。本工程地震烈度为7度,设计分组为第一组,场地类别为Ⅱ类,框架抗震等级为三级。基本风压为0.35kN/m2,基本雪压为0.40kN/m2。楼、屋盖均采用现浇钢筋混凝土结构。

本设计是以“简单、实用、经济、安全”为核心的设计原则。按照设计规范来完成本工程的结构设计。

本设计方案根据设计资料先画出建筑施工图,先进行荷载的标准值计算,接着采用弯矩二次分配法,做出弯矩图,剪力图,轴力图。横向框架在水平地震作用下的内力和位移计算,横向框架在风荷载作用下的内力和位移计算,然后进行内力组合计算,找出最不利的一组或几组内力组合,进行安全结构计算配筋并绘图。

整个设计过程中,遵循设计资料和相关的最新规范,对设计的各个环节进行全面的分析。始终围绕着设计的核心原则进行设计。

【关键词】: 框架结构、内力组合、结构配筋

Abstract

For hua yu office building structure design of this project, the adoption of concrete frame structures, the office building for five layer reinforced concrete structure system, the underlying the height of 3.9 m, other layers of high of 3.6 m, building area of about 3100. This design engineering seismic intensity of 7 degrees, grouped into the first group, site category for Ⅱ, frame aseismic levels for level 3. The basic wind pressure is 0.35 kN /m2, basic snow pressure is 0.40 kN /m2. Floor, roof adopts the cast-in-place reinforced concrete structure.

This design is based on \

This design according to the design data to draw the construction plan, load standard values calculated first, and then USES the bending moment secondary distribution method, make the bending moment diagram and shear diagram, shaft trying to. Transverse frame under horizontal seismic action of internal force and displacement calculation, horizontal framework under the wind load of the internal force and displacement calculation, and then the combination of internal force calculation, find out the most unfavorable one or several groups of internal force combination, the security structure calculation of reinforcement and drawing.

The whole design process, follow the latest specification, design data and related to the design of each link to conduct a comprehensive analysis. Always surround the core principles of design.

key words : frame structure, internal force combination, structure reinforcement

目 录

摘要(Abstract) .............................................................. I 第一章 设计资料 .............................................................. 1

1.1工程概况 ............................................................ 1 1.2地质水文条件 ........................................................ 1 1.3气象条件 ............................................................ 1 1.4材料使用 ............................................................. 1 第二章 结构设计 .............................................................. 2

2.1 结构布置和结构选型 ................................................... 2

2.1.1 结构布置 ....................................................... 2 2.1.2梁柱截面尺寸初估 ............................................... 2 2.1.3结构选型 ....................................................... 4 2.2 框架的计算简图 ....................................................... 4

2.2.1 计算简图说明 ................................................... 4 2.2.2 框架梁柱的线刚度计算 ........................................... 5 2.3 荷载计算 ............................................................. 6

2.3.1.恒载标准值计算 ................................................. 6 2.3.2活荷载标准值计算 ............................................... 8 2.3.3横向框架在恒荷载和活荷载作用下的计算简图 ....................... 9 2.3.4横向框架在重力荷载代表值作用下计算简图 ........................ 12 2.4内力计算 ............................................................ 15

2.4.1恒载作用下的内力计算 .......................................... 15 2.4.2 活载作用的内力计算 ............................................ 20 2.4.3重力荷载代表值作用下的内力计算 ................................ 25

第三章 横向框架在风荷载作用下的内力和位移计算 .............................. 31

3.1横向框架在风荷载作用下的计算 ........................................ 31 3.2 风荷载作用下框架位移计算 ............................................ 31 3.3 风荷载作用下框架内力的计算 .......................................... 33 第四章 横向框架在水平地震作用下的内力和位移计算 ............................. 37

4.1 水平地震作用下结构各层的总重力荷载代表值计算 ........................ 38 4.2横向框架在水平地震作用下的内力和位移计算 ............................ 40 4.3水平地震作用下框架内力计算 .......................................... 42 第五章 内力组合 ............................................................. 46

5.1内力换算 ............................................................ 46 5.2框架梁、柱的内力组合 ................................................ 50

第六章 框架梁、柱配筋 ....................................................... 63

6.1 框架柱配筋计算 ..................................................... 63 6.2 框架梁设计 .......................................................... 66 ......................................................... 73 第七章 楼板配筋计算

7.1楼板配筋计算 ........................................................ 73 7.2板的配筋计算 ........................................................ 74 第八章 楼梯配筋计算 ......................................................... 76

8.1楼梯板配筋计算 ...................................................... 76 8.2 平台板设计 .......................................................... 77 8.3 平台梁设计 .......................................................... 78 第九章 基础设计 ............................................................. 80

9.1 A柱基础设计: ...................................................... 80 9.2 B柱基础设计: ...................................................... 82 参 考 文 献 ................................................................. 85 谢 辞 ...................................................................... 86

1.1工程概况

(1)工程名称:华宇办公楼框架结构设计;建设地点:九江市郊区

(2)建筑概况:该办公楼为五层钢筋混泥土结构体系,底层层高为3.9m,其它层层层高为3.6m,室内外高差为0.45m。具体情况可参见平面布置图和剖面图,建筑面积约3100m2,采用室内楼梯,使用年限为50年。

1.2地质水文条件

(1)水文资料:九江地区属亚热带季风气候区,经勘测发现地下稳定水位距地坪-7m。

(2)工程地质条件:本工程地震烈度为7度,设计分组为第一组,场地类别为Ⅱ类,框架抗震等级为三级。

地质资料:土层深度由自然地坪算起,见下表1-1 表 1-1

1.3

(1)基本风压:0.35kN/m2,地面粗糙度为B类。 (2)基本雪压:雪荷载为0.40kN/m2

1.4材料使用

混凝土:梁柱板均采用C30混凝土,混凝土垫层的为C15。

钢筋:钢筋采用热轧钢筋HRB400,HRB335,其余采用热轧钢筋HRB235。

2.1 结构布置和结构选型

2.1.1 结构布置

本工程结构柱网布置如下图2-1所示

图2-1结构柱网布置图

2.1.2梁柱截面尺寸初估

1.柱的截面尺寸

依据《建筑抗震设计规范》(GB50011—2010)的规定,框架柱的截面尺寸应满足最小尺寸要求、最小刚度以及轴压比要求。初步选取各层柱截面为500mm×500mm。然后进行验算。 (1)底层最小刚度验算:

l0

4..5

9.8

满足最小刚度要求。 (2)轴压比验算:

GiiG(轴压比),[说明] 根据抗震设防烈度、结构形式、fcAfcA

其中由于抗震等级为三级,故=0.9,G为单位建筑面积上的重力荷载值,近视取15kN/m2,i为层数。

Gi(3.91.0)8.0151035 0.812

2.梁截面尺寸初选 (1)AB,CD跨

1111

h=~l~6500800mm~550mm

812812取h=600mm

1111

b=~h~600300mm~200mm

2323

取b=250mm

故AB,CD跨横向框架尺寸为250mm600mm (2)BC跨

1111

h=~l~2400200mm~300mm

812812考虑到刚度因素,取h=500mm

1111

b=~h~500250mm~167mm 2323

取b=250mm

故BC跨横向框架尺寸为250mm500mm (3)纵向框架

1111

h=~l~80001000mm~670mm

812812取h=700mm

1111

b=~h~700350mm~233mm 2323

取b=300mm

故纵向框架梁的尺寸为300mm700mm (4)横向次梁

1111

h=~l~6500800mm~550mm

812812取h=600mm

1111

b=~h~600300mm~200mm

2323

取b=250mm

故横向次梁的尺寸为250mm600mm (5)纵向次梁

1111

h=~l~4000500mm~340mm

812812

取h=400mm

1111

b=~h~400200mm~133mm

2323

根据规范要求b200mm,取b=200mm 故纵向次梁的尺寸为200mm400mm

[说明]梁柱的截面尺寸应满足《建筑抗震设计规范》(GB50011-2010)中6.3.1条以及6.3.6条的要求。 2.1.3结构选型

根据建筑办公楼的要求,为使平面布置灵活,获得较大的使用空间,本结构采用混凝土框架结构体系,屋面结构采用现浇混凝土肋型屋盖刚柔性结合的屋面。内外墙都是200mm,楼面结构,采用现浇混凝土肋型楼盖。楼梯结构,采用混凝土板式楼梯。现浇板的厚度;[说明]①判别现浇楼板是单向板还是单向板;②按最小刚度原则确定板厚; h=4.80mm,所以板厚取h=120mm

2.2 框架的计算简图

2.2.1 计算简图说明

本设计选用柱下独立基础,基础顶面标高为-1.0m(室外地坪以下0.55m)取3-3轴上的一榀框架计算,假定框架柱嵌固于基础顶,框架梁与柱刚接,由于各层柱截面尺寸不变,故25层的计算高度为3.6m,第一层的计算高度为4.9m计算简图如下图2-2所示。

图 2-2横向框架计算简图

2.2.2 框架梁柱的线刚度计算

1.框架梁线刚度计算

由于现浇楼面可以作为梁的有效翼缘,增大梁的有效刚度,减少框架测移。 所以对边框架梁取I=1.5I0,对中框架梁I=2I0。

bh30.250.63

2.09.010-3m4 边跨梁: I边2.01212EI3.01079.01034.15104kNm i边L6.5bh30.250.53

=2.0=5.2110-3m4 中跨梁: I中=2.01212EI3.01075.211036.51104KNm i中L2.4

2.框架柱的线刚度计算

bh30.50.53

5.2110-3m4 柱: I柱1212

i底层

EI3.01075.211033.19104kNm L4.9

i其它层

EI3.01075.211034.34104kNm L3.6

3.相对线刚度计算

取i底层1.00,则其余杆件相对线刚度为:

4.15104

i边1.31

3.191046.51104

i中2.04

3.19104 i其它层

4.341041.36 43.1910

相对线刚度表如下图2-3所示:

图 2-3梁柱相对线刚度

2.3 荷载计算

2.3.1.恒载标准值计算

1.屋面:

防水层(刚性)30厚C20细石混凝土防水 1.0kNm2 防水层(柔性)三毡四油铺小石子 0.4kNm2

找平层:15厚水泥砂浆 0.01520kNm30.30kNm2 找坡层:40厚水泥石灰焦砂浆3‰找平 0.0414kNm30.56kNm2 保温层:80厚矿渣水泥 0.0814.5kNm31.16kNm2 结构层:120厚现浇钢筋混凝土 0.1225kNm33.0kNm2 抹灰层:10厚混合砂浆 0.0117kNm30.17kNm2 合计: 6.59kNm2 2.各层楼面(含走廊)

水磨石地面(10mm面层,20mm水泥砂浆打底) 0.65kNm2 结构层:120mm厚现浇钢筋混凝土板 0.1225kNm33.0kNm2 抹灰层:10mm厚混合砂浆 0.0117kNm30.17kNm2 合计: 3.82kNm2 3.梁自重:

hb300mm700mm

0.30.7-0.1225kNm30.010.7-0.12217kNm34.55kNm

hb250mm600mm

0.250.6-0.1225kNm30.010.6-0.12217kNm33.16kNm hb250mm500mm

0.250.5-0.1225kNm30.010.5-0.12217kNm32.51kNm

hb200mm400mm

0.20.4-0.1225kNm30.010.4-0.12217kNm31.50kNm 4.柱自重

hb500mm500mm

0.50.525kNm30.010.5417kNm36.59kNm 5.外纵墙自重 底层:

纵墙; 4.9-0.78.0-0.5-22.42.30.211.848.29kN 10mm水泥粉刷墙面: 4.98.0-0.5-22.42.320.012010.28kN 1.35m高的贴瓷砖外墙面: 8.01.350.55.4kN 塑钢窗(2.4×2.3): 2.42.320.454.97kN 合计: 63.97kN 标准层;

纵墙: 3.6-0.78.0-0.5-22.42.30.211.828.67kN 10mm水泥粉刷墙面: 3.68.0-0.5-22.42.320.01206.96kN 塑钢窗(2.4×2.0): 2.42.020.454.32kN

合计: 39.95kN 6.内纵墙自重: 底层:

纵墙: 4.9-0.78.0-0.5-21.22.10.211.867.54kN 塑钢门(2.1×1.2): 1.22.120.452.27kN 10mm水泥粉刷墙面:3.9-0.78.0-0.5-21.22.120.01207.58kN 合计: 77.39kN 标准层:

纵墙: 3.6-0.78.0-0.5-21.22.10.211.839.44kN 塑钢门(2.1×1.2): 1.22.120.452.27kN 10mm水泥粉刷墙面:3.6-0.78.0-0.5-21.22.120.01206.68kN 合计: 48.39kN 7.内横墙自重: 底层:

横墙: 4.9-0.66.5-0.50.211.860.89kN 10mm水泥粉刷墙面: 3.9-0.66.5-0.520.01207.92kN 合计: 68.81kN 标准层:

横墙: 3.6-0.66.5-0.50.211.842.48kN 10mm水泥粉刷墙面: 3.6-0.66.5-0.520.01207.20kN 合计: 49.68kN 8.BC墙重: 标准层:

横墙:3.6-0.52.4-0.5-1.520.211.86.82kN

10mm水泥粉刷墙面:3.62.4-0.5-1.5220.01201.54kN 窗:1.520.451.35kN

合计: 9.71kN

2.3.2活荷载标准值计算

1.屋面与楼面活荷载标准值: 不上人屋面:0.5kNm2

楼面:办公室:2.0kNm2:走廊:2.5kNm2 2雪荷载:0.40kNm2

雪荷载标准值:skurs01.00.400.40kN

屋面活荷载和雪荷载不同时考虑,二者中取大值。

2.3.3横向框架在恒荷载和活荷载作用下的计算简图

1.屋面板传荷载:

板传至梁上的三角形或梯形荷载为均布荷载,荷载的传递示意图,如下图

2-4

图2-4板荷载传递示意图

(1)恒载:

由双向板转来的梯形荷载的等效均布荷载为:

23

22

6.5921-2222.14kNm

6.56.5

由双向板传递来的三角形荷载的等效均布荷载为:

5

6.9528.24kNm

8 由单向板传递来的荷载

6.59(2)活载:

由双向板传递来的梯形荷载的等效均布荷载为:

2.4

7.91kNm 2

23

22

0.521-221.68kNm

6.56.5

由双向板传递来的三角形荷载的等效均布荷载为:

5

0.520.63kNm

8

由单向板传递来的荷载: 0.5

2.楼面板传荷载 (1)恒载:

由双向板传递来的梯形荷载的等效均布荷载为:

23

22

3.8221-2212.84kNm

6.56.5

2.4

0.60kNm 2

由双向板传递来的三角形荷载的等效均布荷载为:

5

3.8224.78kNm

8

由单向板传递来的荷载: 3.82 (2)活载:

由双向板传递来的梯形荷载的等效均布荷载为:

23

22

221-226.72kNm

6.56.5

2.4

4.58kNm 2

由双向板传递来的三角形荷载的等效均布荷载为:

5

222.50kNm

8

由单向板传递来的荷载: 2.5

2.4

3.0kNm 2

3. A―B,C―D轴间框架梁均布荷载为: 屋面梁:恒载=梁自重+板传荷载

=3.16kNm22.14kNm25.30kNm 活载=板传荷载=1.68kNm 楼面梁:恒载=梁自重+板传荷载

=3.16kNm12.84kNm16.00kNm

活载=板传荷载=6.72kNm 4. B―C轴间框架梁均布荷载为: 屋面梁:恒载=梁自重 =2.51kNm 活载=0 楼面梁:恒载=梁自重 =2.51kNm 活载=0

5. A、D轴柱纵向集中荷载的计算: 顶层柱:

女儿墙自重(做法:墙高800mm,100mm的混凝土压顶)

0.2m0.8m11.8kNm325kNm30.1m0.2m20.9m0.2m0.5kNm33.39kNm恒载=女儿墙自重+梁自重+板传给梁的荷载

=3.398.04.558.0-0.58.248.03.166.5222.146.52209.39kN 活载=板传给梁的荷载

=0.6381.686.520.66.5212.45kN 标准层柱:

恒载=梁自重+板传给梁的荷载 =

63.9749.684.558.0-0.54.788.0

3.166.5212.846.52238.02kN

活载=板传给梁的荷载

=0.6381.686.520.66.5212.45kN 6. B、C轴柱纵向集中荷载的计算: 顶层柱:

恒载=梁自重+板传给梁的荷载 =

4.558.0-0.58.248.03.166.52

22.146.526.5982.42245.53kN

活载=板传给梁的荷载

=0.6381.686.520.6812.45kN 标准层柱:

恒载=梁自重+板传给梁的荷载 =

48.3949.684.558.0-0.54.788.03.166.52

12.846.523.8282.42259.11kN

活载=板传给梁的荷载

=2.583.086.726.5265.84kN

由上可作出框架分别在恒、活荷载作用下的受荷总图,如下图2-5,2-6所示

图2-5恒荷载作用下的受荷图

图2-6活荷载作用下受荷图

2.3.4横向框架在重力荷载代表值作用下计算简图

屋面重力荷载代表值=屋面恒荷载标准值+0.5雪荷载标准值 楼面重力荷载代表值=楼面恒荷载标准值+0.5楼面活荷载标准值 1.第四层框架重力荷载代表值 (1)AB梁的均布荷载:3.16kNm

(2)板传给AB梁的梯形线荷载:25.30+0.51.34=25.97kNm (3)BC梁的均布荷载:2.51kNm (4)CD梁的均布线荷载:3.16kNm

(5)板传给CD梁的梯形线荷载:25.30+0.51.34=25.97kNm (6)A节点处的集中荷载:FA=209.39+0.59.96=214.37kN (7) B节点处的集中荷载:FB=245.53+0.512.24=251.65kN (8) C节点处的集中荷载:FC=251.65kN (9)D节点处的集中荷载:FD=214.37kN 2.标准层框架重力荷载代表值 (1)AB梁的均布荷载:3.16kNm

(2)板传给AB梁的梯形线荷载:16.00+0.56.72=19.36kNm (3)BC梁的均布荷载:2.51kNm (4)CD梁的均布线荷载:3.16kNm

(5)板传给CD梁的梯形线荷载:16.00+0.56.72=19.36kNm (6)A节点处的集中荷载:FA=238.02+0.551.59=263.82kN (7) B节点处的集中荷载:FB=259.11+0.565.84=292.03kN (8) C节点处的集中荷载:FC=292.03kN (9)D节点处的集中荷载:FD=263.82kN

由上可作出横向框架在重力荷载代表值作用下的受荷图,如下图2-8所示

图2-8重力荷载作用下的受荷图

2.4内力计算

2.4.1恒载作用下的内力计算

由于在竖向恒载作用下,忽略结构变形,即无未知的节点线位移,因此采用弯矩二次分配法进行计算,而框架为对称结构,因此可利用其对称性进行计算。 1.计算分配系数

梁柱传递系数:由为远端固定,因此传递系数C=1/2,分配系数按uik

Sik

S

i1

n

ik

行计算。

图 2-9分配系数图

2.梁的固端弯矩

均布荷载引起是固端弯矩构成节点不平衡弯矩,利用一下公式进行计算。

A

B

C

ql2ql2

M M

123

可求得各梁端弯矩,具体如下表MAB、MBA、MBC

3.弯矩的二次分配过程如下图2-10所示

图 2-10恒载的二次弯矩分配图

4. 绘制内力图

(1)弯矩图如下图所示

1

跨中弯矩M中

ql2MABMBA/2

8

图2-11恒载作用下框架弯矩图

(2)剪力图

根据弯矩和剪力的关系,可采用隔离体方法计算剪力

A

B

1

MABMBAql2

1 -MABMBAql2Fl0F 2l如下图所示

图 2-12 横向框架在恒载作用下的剪力图

(3)轴力图

横向框架作用于柱子轴力值即为梁端剪力值,再加上纵梁传来的轴力值及柱自重,可得出柱轴力图,如下图所示

图 2-13横向框架在恒载作用下是轴力图

2.4.2 活载作用的内力计算

1.梁的固端弯矩

均布活载引起的固端弯矩构成了节点不平衡弯矩,利用一下公式进行计算,可求得各梁端弯矩。

2.弯矩的二次分配过程如下图所示

图2-14活载的二次弯矩分配图

3.绘制内力图

(1)弯矩图,如下图所示

1

M中

ql2MABMBA/2

8

图2-15横向框架活载作用下的弯矩图

(2)剪力图

根据弯矩和剪力的关系,可采用隔离体方法计算剪力

A

B

1

MABMBAql2

1 -MABMBAql2Fl0F 2l 绘制剪力图如下

图2-16横向框架活载作用下的剪力图

(3)轴力图

横向框架作用于柱子轴力值即为梁端剪力值,再加上纵梁传来的活载轴力值可

得出活载作用下的轴力图,如下图所示。

图2-17横向框架在活载作用用下的轴力图

2.4.3重力荷载代表值作用下的内力计算

1.梁的固端弯矩

采用弯矩二次分配法计算框架的重力荷载作用下的弯矩分配过程如下图所示

图 2-18 横向框架重力荷载代表值作用下的二次弯矩分配图

3.绘制内力图

(1)弯矩图如下图所示

1

M中ql2MABMBA/2

8

图2-19横向框架在重力荷载代表值作用下的弯矩图

根据弯矩和剪力的关系,可采用隔离体方法计算剪力

A

B

1

MABMBAql2

1 -MABMBAql2Fl0F 2l 绘制剪力图如下

图2-20横向框架在重力荷载代表值作用下的剪力图

横向框架作用于柱子轴力值即为梁端剪力值,再加上纵梁传来的活载轴力值可得出活载作用下的轴力图,如下图所示。

图 2-21横向框架在重力荷载代表值作用下的轴力图

第三章 横向框架在风荷载作用下的内力和位移计算

3.1横向框架在风荷载作用下的计算

作用在屋面梁和楼面梁节点处的集中风荷载标准值: Wk

zusuzw0(hihj)B/2

为了简化计算,通常将计算单元范围内外墙面分布荷载转化为等量的作用于楼面的集中荷载,式中:

w0-- 基本分压,九江为0.35kN/m2

uz--分压高度变化系数,因建设地点处于城市郊区,地面粗糙度为B类,由

荷载与结构设计方法查得。

us--风荷载体型系数,由荷载与结构设计方法表3-9查得。 z-- 风振系数,由于结构高度小于30m,且高宽比19.3/15.4

表3-1风荷载标准值计算

3.2 风荷载作用下框架位移计算

1.侧移刚度D的计算(见下表)

表3-2横向框架2-5层D值的计算

表3-3横向框架底层D值的计算

2.风荷载作用下框架侧移验算

水平荷载作用下框架层间侧移验算可以按下式计算: uj

vpj

Dij

式中: vpj --第j层的剪力

Dij--第j层所有柱的抗侧刚度之和 j层侧移:uj

n

u

j1

j

j

顶层侧移:uuj

j1

框架在风荷载下侧移的计算(见下表3-4)

表3-4

层间最大侧移值为:满足要求。

1u111

3.3 风荷载作用下框架内力的计算

1.应用D值法进行计算 (1)求各柱的反弯点位置 计算公式:Y=

h=(0123)h

表3-5 A、D轴柱的反弯点位置

表3-6 B、C轴柱的反弯点位置

2.左风作用下的内力

框架柱的杆端弯矩和梁端弯矩按以下公式计算 Mc上V1h Mc下V h 边柱节点:Mb总j=Mc下j+1Mc上j 中柱节点:Mb左j=

ib左ib右

, Mb右jMc下j+1Mc上j)Mc下j1Mc上j

ib右+ib左ib左ib右



则左风作用下框架柱内力计算如下表3-7

表3-7 风荷载作用下A、D轴框架柱剪力和梁柱端弯矩计算表

表3-8 风荷载作用下B、C轴框架柱剪力和梁柱端弯矩计算表

表3-9 风荷载作用下框架柱与梁端剪力

2.绘制内力图

(1)弯矩图,风荷载作用下的弯矩图如下图所示

图3-10横向框架在风荷载作用下的弯矩图

(2)剪力图

根据弯矩和剪力的关系,可采用隔离体方法计算剪力

A

B

FQ

MAMB

l

图3-11横向框架在风荷载作用下的剪力图

(3)轴力图

根据梁端剪力可以求出框架柱在风荷载作用下的轴力图。

图3-12横向框架在风荷载作用下柱的轴力图

第四章 横向框架在水平地震作用下的内力和位移计

本设计建筑总高度为19.2m,没有超过40m,以剪切变形为主,且是质量和刚度分布比较均匀的建筑物,可采用底部剪力法的简化方法计算水平地震作用。结构底部总剪力与地震影响系数及各质点重力荷载代表值有关,为计算各质点的重力荷载代表值,本设计分别计算各楼面层的重量,然后上下各半的形式分配并集中与楼面层的原则计算各质点的重力荷载的代表值。结构自振周期采用能量法进行计算,水平地震作用下内力及位移分析均采用D值法进行。

4.1 水平地震作用下结构各层的总重力荷载代表值计算

1.顶层重力荷载代表值

(4015.4)23.39375.60kN (1)女儿墙自重:G女儿墙

.40kN (2)屋面板自重:G屋面板4015.46.594059

(8-0.5)4.5554682.50kN (3)纵墙框架梁自重:G纵梁

(4)横墙框架梁自重:

.10kN G横梁3.166.5-0.5622.512.4-0.56256

(5)次梁自重:G次梁3.166.510205.40kN

1

(6)柱自重:G柱6.593.6-0.1246275.02kN

2

(7)纵墙自重:G纵墙39.955248.3954 (8)横墙自重:G横墙49.68149.712

1

417.52kN 2

1

357.47kN 2

(9)雪荷载:G雪0.50.415.440123.20kN

(10)重力荷载代表值汇总:G顶层=G女儿+G屋面板+G纵梁+G横梁+G次梁+ G柱

+G纵墙+G横墙+G雪=6752.21kN

2.标准层重力荷载代表值

.12kN (1)楼面板自重:G楼面板4015.43.822253

(2)纵墙框架梁自重:G纵梁=682.50kN (3)横墙框架梁自重:G横梁=256.10kN (4)次梁自重:G次梁=205.40kN

(5)柱自重:G柱775.01kN

(6)纵墙自重:G纵梁=417.52×2=835.04kN

(7)横墙自重:G横墙=49.68×16+9.71×2=814.30kN

1

(8)活荷载:Q3=26.53222.56.5422546.00kN

2 (9)楼梯:G楼梯

1

221110.50kN 2

(10)重力荷载代表值汇总:G标准层=G楼面板+G纵梁+G横梁+G次梁+

G柱+G纵墙+G楼梯+G横墙+Q3

G46353.33kN

.85kN G2G36463

3.底层重力荷载代表值

.12kN (1)楼面板自重:G楼面板4015.43.822253

(2)纵墙框架梁自重:G纵梁=682.50kN (3)横墙框架梁自重:G横梁=265.10kN (4)次梁自重:G次梁=205.40kN

(5)柱自重:G柱6.593.6-0.120.54.9-0.120.546653.20kN (6)纵墙自重:G纵梁=417.520.563.975277.39451085.63kN (7)横墙自重:G横墙=357.470.568.811610.712918.66kN (8)活荷载:Q1=546.10kN (9)楼梯:G楼梯

1

221232226.50kN 2

(10)重力荷载代表值汇总:G标准层=G楼面板+G纵梁+G横梁+G次梁+ G柱+G纵墙+ G横墙+G楼梯+Q1=6927.11kN

4.集中于各楼层高处的重力荷载代表值Gi的计算简图如下

6927.11KN

图4-1 各层重力荷载代表值

4.2横向框架在水平地震作用下的内力和位移计算

1.框架线刚度计算(前面已计算) 2.柱的侧移刚度D计算

(1)2-5层:D=(12974+22103)26=420924kN×m (2)首层:D=(5149+6778)26=143124kN×m 3.横向框架自振周期计算(计算过程见下表4-2)

表4-2

GU

i

i

10625.3 GiUi3532.85

由结构的自振周期公式T12T

式中:T--基本周期调整系数,考虑填充墙使框架自振周期减小,

取T=0.6(经验值)。

ui--各质点承受相当于其重力荷载代表值的水平节点力作

用时质点产生的侧移量。

所以T120.6

3532.85

0.692

10625.3

4.水平地震作用标准值和位移计算 (1)地震影响系数

本工程设防烈为七度,设计地震加速度为0.10g,由表3-4查得

amax=0.08,

0.9

类场地,设计地震分组为第一组,由表3-2查得Tg=0.35。

Tg

所以a1amax=0.043s

T1

又因为Tg=0.35s,T1=0.692s>1.4Tg=0.49s,所以得考虑地震作用系数n,

n=0.08T1+0.07=0.125。FEKa1G=0.0430.8532960.61=1204.70kN

按式(3-84)计算:FnnFEK=0.1251204.70=150.60kN (2)各质点水平地震作用标准值,楼层地震剪力及楼层层间位移计算 结构水平地震作用标准值按下式计算 Fi

GiHi

GH

ii1

n

FEK(1n)

i

各质点的水平地震作用标准值,楼层地震剪力及楼层间相对侧移量计算如下表4-3

表4-3

最大位移发生在的一层,其层间位移角e=



4.9582550

满足《建筑设计抗震规范》(GB50011-2010)第5.5.1条规定的位移限值[e]=1/550要求。 (3)剪重比验算

为了确保结构的安全与稳定,需进行结构剪重比的验算,具体如下表4-4

表4-4

4.3水平地震作用下框架内力计算

1.计算反弯点高度

表4-5 A、D轴柱的反弯点位置

表4-6 B、C轴柱的反弯点位置

表4-7 A、D轴柱框架柱剪力和梁柱端弯矩计算

表4-8 B、C轴柱框架柱剪力和梁柱端弯矩的计算

表4-9 各层框架柱轴力和各跨梁端剪力计算

3.绘制内力图 (1)弯矩图

图4-10横向框架在水平地震作用下的弯矩图

(2)剪力图

根据弯矩和剪力的关系,可采用隔离体方法计算剪力

A

B

FQ

绘制剪力图如下

MAMB

l

图4-11横向框架在水平地震作用下的剪力图

(3)轴力图

横向框架在水平地震作用下的柱的轴力就等于梁端传来的梁端剪力,横向框架在水平地震作用下的轴力图如下图所示。

题 目

毕 业 论 文 (设 计)

英文题目 院 系 土木工程与城市建设学院 专 业 姓 名 黄 海 年 级 2010级土A1014 指导教师 戴 嘉 兴

二零一四年六月

摘 要

本工程为华宇办公楼的结构设计,采用混凝土框架结构, 该办公楼为五层钢筋混泥土结构体系,底层层高为3.9m,其它层层高为3.6m,建筑面积约3100m2。本工程地震烈度为7度,设计分组为第一组,场地类别为Ⅱ类,框架抗震等级为三级。基本风压为0.35kN/m2,基本雪压为0.40kN/m2。楼、屋盖均采用现浇钢筋混凝土结构。

本设计是以“简单、实用、经济、安全”为核心的设计原则。按照设计规范来完成本工程的结构设计。

本设计方案根据设计资料先画出建筑施工图,先进行荷载的标准值计算,接着采用弯矩二次分配法,做出弯矩图,剪力图,轴力图。横向框架在水平地震作用下的内力和位移计算,横向框架在风荷载作用下的内力和位移计算,然后进行内力组合计算,找出最不利的一组或几组内力组合,进行安全结构计算配筋并绘图。

整个设计过程中,遵循设计资料和相关的最新规范,对设计的各个环节进行全面的分析。始终围绕着设计的核心原则进行设计。

【关键词】: 框架结构、内力组合、结构配筋

Abstract

For hua yu office building structure design of this project, the adoption of concrete frame structures, the office building for five layer reinforced concrete structure system, the underlying the height of 3.9 m, other layers of high of 3.6 m, building area of about 3100. This design engineering seismic intensity of 7 degrees, grouped into the first group, site category for Ⅱ, frame aseismic levels for level 3. The basic wind pressure is 0.35 kN /m2, basic snow pressure is 0.40 kN /m2. Floor, roof adopts the cast-in-place reinforced concrete structure.

This design is based on \

This design according to the design data to draw the construction plan, load standard values calculated first, and then USES the bending moment secondary distribution method, make the bending moment diagram and shear diagram, shaft trying to. Transverse frame under horizontal seismic action of internal force and displacement calculation, horizontal framework under the wind load of the internal force and displacement calculation, and then the combination of internal force calculation, find out the most unfavorable one or several groups of internal force combination, the security structure calculation of reinforcement and drawing.

The whole design process, follow the latest specification, design data and related to the design of each link to conduct a comprehensive analysis. Always surround the core principles of design.

key words : frame structure, internal force combination, structure reinforcement

目 录

摘要(Abstract) .............................................................. I 第一章 设计资料 .............................................................. 1

1.1工程概况 ............................................................ 1 1.2地质水文条件 ........................................................ 1 1.3气象条件 ............................................................ 1 1.4材料使用 ............................................................. 1 第二章 结构设计 .............................................................. 2

2.1 结构布置和结构选型 ................................................... 2

2.1.1 结构布置 ....................................................... 2 2.1.2梁柱截面尺寸初估 ............................................... 2 2.1.3结构选型 ....................................................... 4 2.2 框架的计算简图 ....................................................... 4

2.2.1 计算简图说明 ................................................... 4 2.2.2 框架梁柱的线刚度计算 ........................................... 5 2.3 荷载计算 ............................................................. 6

2.3.1.恒载标准值计算 ................................................. 6 2.3.2活荷载标准值计算 ............................................... 8 2.3.3横向框架在恒荷载和活荷载作用下的计算简图 ....................... 9 2.3.4横向框架在重力荷载代表值作用下计算简图 ........................ 12 2.4内力计算 ............................................................ 15

2.4.1恒载作用下的内力计算 .......................................... 15 2.4.2 活载作用的内力计算 ............................................ 20 2.4.3重力荷载代表值作用下的内力计算 ................................ 25

第三章 横向框架在风荷载作用下的内力和位移计算 .............................. 31

3.1横向框架在风荷载作用下的计算 ........................................ 31 3.2 风荷载作用下框架位移计算 ............................................ 31 3.3 风荷载作用下框架内力的计算 .......................................... 33 第四章 横向框架在水平地震作用下的内力和位移计算 ............................. 37

4.1 水平地震作用下结构各层的总重力荷载代表值计算 ........................ 38 4.2横向框架在水平地震作用下的内力和位移计算 ............................ 40 4.3水平地震作用下框架内力计算 .......................................... 42 第五章 内力组合 ............................................................. 46

5.1内力换算 ............................................................ 46 5.2框架梁、柱的内力组合 ................................................ 50

第六章 框架梁、柱配筋 ....................................................... 63

6.1 框架柱配筋计算 ..................................................... 63 6.2 框架梁设计 .......................................................... 66 ......................................................... 73 第七章 楼板配筋计算

7.1楼板配筋计算 ........................................................ 73 7.2板的配筋计算 ........................................................ 74 第八章 楼梯配筋计算 ......................................................... 76

8.1楼梯板配筋计算 ...................................................... 76 8.2 平台板设计 .......................................................... 77 8.3 平台梁设计 .......................................................... 78 第九章 基础设计 ............................................................. 80

9.1 A柱基础设计: ...................................................... 80 9.2 B柱基础设计: ...................................................... 82 参 考 文 献 ................................................................. 85 谢 辞 ...................................................................... 86

1.1工程概况

(1)工程名称:华宇办公楼框架结构设计;建设地点:九江市郊区

(2)建筑概况:该办公楼为五层钢筋混泥土结构体系,底层层高为3.9m,其它层层层高为3.6m,室内外高差为0.45m。具体情况可参见平面布置图和剖面图,建筑面积约3100m2,采用室内楼梯,使用年限为50年。

1.2地质水文条件

(1)水文资料:九江地区属亚热带季风气候区,经勘测发现地下稳定水位距地坪-7m。

(2)工程地质条件:本工程地震烈度为7度,设计分组为第一组,场地类别为Ⅱ类,框架抗震等级为三级。

地质资料:土层深度由自然地坪算起,见下表1-1 表 1-1

1.3

(1)基本风压:0.35kN/m2,地面粗糙度为B类。 (2)基本雪压:雪荷载为0.40kN/m2

1.4材料使用

混凝土:梁柱板均采用C30混凝土,混凝土垫层的为C15。

钢筋:钢筋采用热轧钢筋HRB400,HRB335,其余采用热轧钢筋HRB235。

2.1 结构布置和结构选型

2.1.1 结构布置

本工程结构柱网布置如下图2-1所示

图2-1结构柱网布置图

2.1.2梁柱截面尺寸初估

1.柱的截面尺寸

依据《建筑抗震设计规范》(GB50011—2010)的规定,框架柱的截面尺寸应满足最小尺寸要求、最小刚度以及轴压比要求。初步选取各层柱截面为500mm×500mm。然后进行验算。 (1)底层最小刚度验算:

l0

4..5

9.8

满足最小刚度要求。 (2)轴压比验算:

GiiG(轴压比),[说明] 根据抗震设防烈度、结构形式、fcAfcA

其中由于抗震等级为三级,故=0.9,G为单位建筑面积上的重力荷载值,近视取15kN/m2,i为层数。

Gi(3.91.0)8.0151035 0.812

2.梁截面尺寸初选 (1)AB,CD跨

1111

h=~l~6500800mm~550mm

812812取h=600mm

1111

b=~h~600300mm~200mm

2323

取b=250mm

故AB,CD跨横向框架尺寸为250mm600mm (2)BC跨

1111

h=~l~2400200mm~300mm

812812考虑到刚度因素,取h=500mm

1111

b=~h~500250mm~167mm 2323

取b=250mm

故BC跨横向框架尺寸为250mm500mm (3)纵向框架

1111

h=~l~80001000mm~670mm

812812取h=700mm

1111

b=~h~700350mm~233mm 2323

取b=300mm

故纵向框架梁的尺寸为300mm700mm (4)横向次梁

1111

h=~l~6500800mm~550mm

812812取h=600mm

1111

b=~h~600300mm~200mm

2323

取b=250mm

故横向次梁的尺寸为250mm600mm (5)纵向次梁

1111

h=~l~4000500mm~340mm

812812

取h=400mm

1111

b=~h~400200mm~133mm

2323

根据规范要求b200mm,取b=200mm 故纵向次梁的尺寸为200mm400mm

[说明]梁柱的截面尺寸应满足《建筑抗震设计规范》(GB50011-2010)中6.3.1条以及6.3.6条的要求。 2.1.3结构选型

根据建筑办公楼的要求,为使平面布置灵活,获得较大的使用空间,本结构采用混凝土框架结构体系,屋面结构采用现浇混凝土肋型屋盖刚柔性结合的屋面。内外墙都是200mm,楼面结构,采用现浇混凝土肋型楼盖。楼梯结构,采用混凝土板式楼梯。现浇板的厚度;[说明]①判别现浇楼板是单向板还是单向板;②按最小刚度原则确定板厚; h=4.80mm,所以板厚取h=120mm

2.2 框架的计算简图

2.2.1 计算简图说明

本设计选用柱下独立基础,基础顶面标高为-1.0m(室外地坪以下0.55m)取3-3轴上的一榀框架计算,假定框架柱嵌固于基础顶,框架梁与柱刚接,由于各层柱截面尺寸不变,故25层的计算高度为3.6m,第一层的计算高度为4.9m计算简图如下图2-2所示。

图 2-2横向框架计算简图

2.2.2 框架梁柱的线刚度计算

1.框架梁线刚度计算

由于现浇楼面可以作为梁的有效翼缘,增大梁的有效刚度,减少框架测移。 所以对边框架梁取I=1.5I0,对中框架梁I=2I0。

bh30.250.63

2.09.010-3m4 边跨梁: I边2.01212EI3.01079.01034.15104kNm i边L6.5bh30.250.53

=2.0=5.2110-3m4 中跨梁: I中=2.01212EI3.01075.211036.51104KNm i中L2.4

2.框架柱的线刚度计算

bh30.50.53

5.2110-3m4 柱: I柱1212

i底层

EI3.01075.211033.19104kNm L4.9

i其它层

EI3.01075.211034.34104kNm L3.6

3.相对线刚度计算

取i底层1.00,则其余杆件相对线刚度为:

4.15104

i边1.31

3.191046.51104

i中2.04

3.19104 i其它层

4.341041.36 43.1910

相对线刚度表如下图2-3所示:

图 2-3梁柱相对线刚度

2.3 荷载计算

2.3.1.恒载标准值计算

1.屋面:

防水层(刚性)30厚C20细石混凝土防水 1.0kNm2 防水层(柔性)三毡四油铺小石子 0.4kNm2

找平层:15厚水泥砂浆 0.01520kNm30.30kNm2 找坡层:40厚水泥石灰焦砂浆3‰找平 0.0414kNm30.56kNm2 保温层:80厚矿渣水泥 0.0814.5kNm31.16kNm2 结构层:120厚现浇钢筋混凝土 0.1225kNm33.0kNm2 抹灰层:10厚混合砂浆 0.0117kNm30.17kNm2 合计: 6.59kNm2 2.各层楼面(含走廊)

水磨石地面(10mm面层,20mm水泥砂浆打底) 0.65kNm2 结构层:120mm厚现浇钢筋混凝土板 0.1225kNm33.0kNm2 抹灰层:10mm厚混合砂浆 0.0117kNm30.17kNm2 合计: 3.82kNm2 3.梁自重:

hb300mm700mm

0.30.7-0.1225kNm30.010.7-0.12217kNm34.55kNm

hb250mm600mm

0.250.6-0.1225kNm30.010.6-0.12217kNm33.16kNm hb250mm500mm

0.250.5-0.1225kNm30.010.5-0.12217kNm32.51kNm

hb200mm400mm

0.20.4-0.1225kNm30.010.4-0.12217kNm31.50kNm 4.柱自重

hb500mm500mm

0.50.525kNm30.010.5417kNm36.59kNm 5.外纵墙自重 底层:

纵墙; 4.9-0.78.0-0.5-22.42.30.211.848.29kN 10mm水泥粉刷墙面: 4.98.0-0.5-22.42.320.012010.28kN 1.35m高的贴瓷砖外墙面: 8.01.350.55.4kN 塑钢窗(2.4×2.3): 2.42.320.454.97kN 合计: 63.97kN 标准层;

纵墙: 3.6-0.78.0-0.5-22.42.30.211.828.67kN 10mm水泥粉刷墙面: 3.68.0-0.5-22.42.320.01206.96kN 塑钢窗(2.4×2.0): 2.42.020.454.32kN

合计: 39.95kN 6.内纵墙自重: 底层:

纵墙: 4.9-0.78.0-0.5-21.22.10.211.867.54kN 塑钢门(2.1×1.2): 1.22.120.452.27kN 10mm水泥粉刷墙面:3.9-0.78.0-0.5-21.22.120.01207.58kN 合计: 77.39kN 标准层:

纵墙: 3.6-0.78.0-0.5-21.22.10.211.839.44kN 塑钢门(2.1×1.2): 1.22.120.452.27kN 10mm水泥粉刷墙面:3.6-0.78.0-0.5-21.22.120.01206.68kN 合计: 48.39kN 7.内横墙自重: 底层:

横墙: 4.9-0.66.5-0.50.211.860.89kN 10mm水泥粉刷墙面: 3.9-0.66.5-0.520.01207.92kN 合计: 68.81kN 标准层:

横墙: 3.6-0.66.5-0.50.211.842.48kN 10mm水泥粉刷墙面: 3.6-0.66.5-0.520.01207.20kN 合计: 49.68kN 8.BC墙重: 标准层:

横墙:3.6-0.52.4-0.5-1.520.211.86.82kN

10mm水泥粉刷墙面:3.62.4-0.5-1.5220.01201.54kN 窗:1.520.451.35kN

合计: 9.71kN

2.3.2活荷载标准值计算

1.屋面与楼面活荷载标准值: 不上人屋面:0.5kNm2

楼面:办公室:2.0kNm2:走廊:2.5kNm2 2雪荷载:0.40kNm2

雪荷载标准值:skurs01.00.400.40kN

屋面活荷载和雪荷载不同时考虑,二者中取大值。

2.3.3横向框架在恒荷载和活荷载作用下的计算简图

1.屋面板传荷载:

板传至梁上的三角形或梯形荷载为均布荷载,荷载的传递示意图,如下图

2-4

图2-4板荷载传递示意图

(1)恒载:

由双向板转来的梯形荷载的等效均布荷载为:

23

22

6.5921-2222.14kNm

6.56.5

由双向板传递来的三角形荷载的等效均布荷载为:

5

6.9528.24kNm

8 由单向板传递来的荷载

6.59(2)活载:

由双向板传递来的梯形荷载的等效均布荷载为:

2.4

7.91kNm 2

23

22

0.521-221.68kNm

6.56.5

由双向板传递来的三角形荷载的等效均布荷载为:

5

0.520.63kNm

8

由单向板传递来的荷载: 0.5

2.楼面板传荷载 (1)恒载:

由双向板传递来的梯形荷载的等效均布荷载为:

23

22

3.8221-2212.84kNm

6.56.5

2.4

0.60kNm 2

由双向板传递来的三角形荷载的等效均布荷载为:

5

3.8224.78kNm

8

由单向板传递来的荷载: 3.82 (2)活载:

由双向板传递来的梯形荷载的等效均布荷载为:

23

22

221-226.72kNm

6.56.5

2.4

4.58kNm 2

由双向板传递来的三角形荷载的等效均布荷载为:

5

222.50kNm

8

由单向板传递来的荷载: 2.5

2.4

3.0kNm 2

3. A―B,C―D轴间框架梁均布荷载为: 屋面梁:恒载=梁自重+板传荷载

=3.16kNm22.14kNm25.30kNm 活载=板传荷载=1.68kNm 楼面梁:恒载=梁自重+板传荷载

=3.16kNm12.84kNm16.00kNm

活载=板传荷载=6.72kNm 4. B―C轴间框架梁均布荷载为: 屋面梁:恒载=梁自重 =2.51kNm 活载=0 楼面梁:恒载=梁自重 =2.51kNm 活载=0

5. A、D轴柱纵向集中荷载的计算: 顶层柱:

女儿墙自重(做法:墙高800mm,100mm的混凝土压顶)

0.2m0.8m11.8kNm325kNm30.1m0.2m20.9m0.2m0.5kNm33.39kNm恒载=女儿墙自重+梁自重+板传给梁的荷载

=3.398.04.558.0-0.58.248.03.166.5222.146.52209.39kN 活载=板传给梁的荷载

=0.6381.686.520.66.5212.45kN 标准层柱:

恒载=梁自重+板传给梁的荷载 =

63.9749.684.558.0-0.54.788.0

3.166.5212.846.52238.02kN

活载=板传给梁的荷载

=0.6381.686.520.66.5212.45kN 6. B、C轴柱纵向集中荷载的计算: 顶层柱:

恒载=梁自重+板传给梁的荷载 =

4.558.0-0.58.248.03.166.52

22.146.526.5982.42245.53kN

活载=板传给梁的荷载

=0.6381.686.520.6812.45kN 标准层柱:

恒载=梁自重+板传给梁的荷载 =

48.3949.684.558.0-0.54.788.03.166.52

12.846.523.8282.42259.11kN

活载=板传给梁的荷载

=2.583.086.726.5265.84kN

由上可作出框架分别在恒、活荷载作用下的受荷总图,如下图2-5,2-6所示

图2-5恒荷载作用下的受荷图

图2-6活荷载作用下受荷图

2.3.4横向框架在重力荷载代表值作用下计算简图

屋面重力荷载代表值=屋面恒荷载标准值+0.5雪荷载标准值 楼面重力荷载代表值=楼面恒荷载标准值+0.5楼面活荷载标准值 1.第四层框架重力荷载代表值 (1)AB梁的均布荷载:3.16kNm

(2)板传给AB梁的梯形线荷载:25.30+0.51.34=25.97kNm (3)BC梁的均布荷载:2.51kNm (4)CD梁的均布线荷载:3.16kNm

(5)板传给CD梁的梯形线荷载:25.30+0.51.34=25.97kNm (6)A节点处的集中荷载:FA=209.39+0.59.96=214.37kN (7) B节点处的集中荷载:FB=245.53+0.512.24=251.65kN (8) C节点处的集中荷载:FC=251.65kN (9)D节点处的集中荷载:FD=214.37kN 2.标准层框架重力荷载代表值 (1)AB梁的均布荷载:3.16kNm

(2)板传给AB梁的梯形线荷载:16.00+0.56.72=19.36kNm (3)BC梁的均布荷载:2.51kNm (4)CD梁的均布线荷载:3.16kNm

(5)板传给CD梁的梯形线荷载:16.00+0.56.72=19.36kNm (6)A节点处的集中荷载:FA=238.02+0.551.59=263.82kN (7) B节点处的集中荷载:FB=259.11+0.565.84=292.03kN (8) C节点处的集中荷载:FC=292.03kN (9)D节点处的集中荷载:FD=263.82kN

由上可作出横向框架在重力荷载代表值作用下的受荷图,如下图2-8所示

图2-8重力荷载作用下的受荷图

2.4内力计算

2.4.1恒载作用下的内力计算

由于在竖向恒载作用下,忽略结构变形,即无未知的节点线位移,因此采用弯矩二次分配法进行计算,而框架为对称结构,因此可利用其对称性进行计算。 1.计算分配系数

梁柱传递系数:由为远端固定,因此传递系数C=1/2,分配系数按uik

Sik

S

i1

n

ik

行计算。

图 2-9分配系数图

2.梁的固端弯矩

均布荷载引起是固端弯矩构成节点不平衡弯矩,利用一下公式进行计算。

A

B

C

ql2ql2

M M

123

可求得各梁端弯矩,具体如下表MAB、MBA、MBC

3.弯矩的二次分配过程如下图2-10所示

图 2-10恒载的二次弯矩分配图

4. 绘制内力图

(1)弯矩图如下图所示

1

跨中弯矩M中

ql2MABMBA/2

8

图2-11恒载作用下框架弯矩图

(2)剪力图

根据弯矩和剪力的关系,可采用隔离体方法计算剪力

A

B

1

MABMBAql2

1 -MABMBAql2Fl0F 2l如下图所示

图 2-12 横向框架在恒载作用下的剪力图

(3)轴力图

横向框架作用于柱子轴力值即为梁端剪力值,再加上纵梁传来的轴力值及柱自重,可得出柱轴力图,如下图所示

图 2-13横向框架在恒载作用下是轴力图

2.4.2 活载作用的内力计算

1.梁的固端弯矩

均布活载引起的固端弯矩构成了节点不平衡弯矩,利用一下公式进行计算,可求得各梁端弯矩。

2.弯矩的二次分配过程如下图所示

图2-14活载的二次弯矩分配图

3.绘制内力图

(1)弯矩图,如下图所示

1

M中

ql2MABMBA/2

8

图2-15横向框架活载作用下的弯矩图

(2)剪力图

根据弯矩和剪力的关系,可采用隔离体方法计算剪力

A

B

1

MABMBAql2

1 -MABMBAql2Fl0F 2l 绘制剪力图如下

图2-16横向框架活载作用下的剪力图

(3)轴力图

横向框架作用于柱子轴力值即为梁端剪力值,再加上纵梁传来的活载轴力值可

得出活载作用下的轴力图,如下图所示。

图2-17横向框架在活载作用用下的轴力图

2.4.3重力荷载代表值作用下的内力计算

1.梁的固端弯矩

采用弯矩二次分配法计算框架的重力荷载作用下的弯矩分配过程如下图所示

图 2-18 横向框架重力荷载代表值作用下的二次弯矩分配图

3.绘制内力图

(1)弯矩图如下图所示

1

M中ql2MABMBA/2

8

图2-19横向框架在重力荷载代表值作用下的弯矩图

根据弯矩和剪力的关系,可采用隔离体方法计算剪力

A

B

1

MABMBAql2

1 -MABMBAql2Fl0F 2l 绘制剪力图如下

图2-20横向框架在重力荷载代表值作用下的剪力图

横向框架作用于柱子轴力值即为梁端剪力值,再加上纵梁传来的活载轴力值可得出活载作用下的轴力图,如下图所示。

图 2-21横向框架在重力荷载代表值作用下的轴力图

第三章 横向框架在风荷载作用下的内力和位移计算

3.1横向框架在风荷载作用下的计算

作用在屋面梁和楼面梁节点处的集中风荷载标准值: Wk

zusuzw0(hihj)B/2

为了简化计算,通常将计算单元范围内外墙面分布荷载转化为等量的作用于楼面的集中荷载,式中:

w0-- 基本分压,九江为0.35kN/m2

uz--分压高度变化系数,因建设地点处于城市郊区,地面粗糙度为B类,由

荷载与结构设计方法查得。

us--风荷载体型系数,由荷载与结构设计方法表3-9查得。 z-- 风振系数,由于结构高度小于30m,且高宽比19.3/15.4

表3-1风荷载标准值计算

3.2 风荷载作用下框架位移计算

1.侧移刚度D的计算(见下表)

表3-2横向框架2-5层D值的计算

表3-3横向框架底层D值的计算

2.风荷载作用下框架侧移验算

水平荷载作用下框架层间侧移验算可以按下式计算: uj

vpj

Dij

式中: vpj --第j层的剪力

Dij--第j层所有柱的抗侧刚度之和 j层侧移:uj

n

u

j1

j

j

顶层侧移:uuj

j1

框架在风荷载下侧移的计算(见下表3-4)

表3-4

层间最大侧移值为:满足要求。

1u111

3.3 风荷载作用下框架内力的计算

1.应用D值法进行计算 (1)求各柱的反弯点位置 计算公式:Y=

h=(0123)h

表3-5 A、D轴柱的反弯点位置

表3-6 B、C轴柱的反弯点位置

2.左风作用下的内力

框架柱的杆端弯矩和梁端弯矩按以下公式计算 Mc上V1h Mc下V h 边柱节点:Mb总j=Mc下j+1Mc上j 中柱节点:Mb左j=

ib左ib右

, Mb右jMc下j+1Mc上j)Mc下j1Mc上j

ib右+ib左ib左ib右



则左风作用下框架柱内力计算如下表3-7

表3-7 风荷载作用下A、D轴框架柱剪力和梁柱端弯矩计算表

表3-8 风荷载作用下B、C轴框架柱剪力和梁柱端弯矩计算表

表3-9 风荷载作用下框架柱与梁端剪力

2.绘制内力图

(1)弯矩图,风荷载作用下的弯矩图如下图所示

图3-10横向框架在风荷载作用下的弯矩图

(2)剪力图

根据弯矩和剪力的关系,可采用隔离体方法计算剪力

A

B

FQ

MAMB

l

图3-11横向框架在风荷载作用下的剪力图

(3)轴力图

根据梁端剪力可以求出框架柱在风荷载作用下的轴力图。

图3-12横向框架在风荷载作用下柱的轴力图

第四章 横向框架在水平地震作用下的内力和位移计

本设计建筑总高度为19.2m,没有超过40m,以剪切变形为主,且是质量和刚度分布比较均匀的建筑物,可采用底部剪力法的简化方法计算水平地震作用。结构底部总剪力与地震影响系数及各质点重力荷载代表值有关,为计算各质点的重力荷载代表值,本设计分别计算各楼面层的重量,然后上下各半的形式分配并集中与楼面层的原则计算各质点的重力荷载的代表值。结构自振周期采用能量法进行计算,水平地震作用下内力及位移分析均采用D值法进行。

4.1 水平地震作用下结构各层的总重力荷载代表值计算

1.顶层重力荷载代表值

(4015.4)23.39375.60kN (1)女儿墙自重:G女儿墙

.40kN (2)屋面板自重:G屋面板4015.46.594059

(8-0.5)4.5554682.50kN (3)纵墙框架梁自重:G纵梁

(4)横墙框架梁自重:

.10kN G横梁3.166.5-0.5622.512.4-0.56256

(5)次梁自重:G次梁3.166.510205.40kN

1

(6)柱自重:G柱6.593.6-0.1246275.02kN

2

(7)纵墙自重:G纵墙39.955248.3954 (8)横墙自重:G横墙49.68149.712

1

417.52kN 2

1

357.47kN 2

(9)雪荷载:G雪0.50.415.440123.20kN

(10)重力荷载代表值汇总:G顶层=G女儿+G屋面板+G纵梁+G横梁+G次梁+ G柱

+G纵墙+G横墙+G雪=6752.21kN

2.标准层重力荷载代表值

.12kN (1)楼面板自重:G楼面板4015.43.822253

(2)纵墙框架梁自重:G纵梁=682.50kN (3)横墙框架梁自重:G横梁=256.10kN (4)次梁自重:G次梁=205.40kN

(5)柱自重:G柱775.01kN

(6)纵墙自重:G纵梁=417.52×2=835.04kN

(7)横墙自重:G横墙=49.68×16+9.71×2=814.30kN

1

(8)活荷载:Q3=26.53222.56.5422546.00kN

2 (9)楼梯:G楼梯

1

221110.50kN 2

(10)重力荷载代表值汇总:G标准层=G楼面板+G纵梁+G横梁+G次梁+

G柱+G纵墙+G楼梯+G横墙+Q3

G46353.33kN

.85kN G2G36463

3.底层重力荷载代表值

.12kN (1)楼面板自重:G楼面板4015.43.822253

(2)纵墙框架梁自重:G纵梁=682.50kN (3)横墙框架梁自重:G横梁=265.10kN (4)次梁自重:G次梁=205.40kN

(5)柱自重:G柱6.593.6-0.120.54.9-0.120.546653.20kN (6)纵墙自重:G纵梁=417.520.563.975277.39451085.63kN (7)横墙自重:G横墙=357.470.568.811610.712918.66kN (8)活荷载:Q1=546.10kN (9)楼梯:G楼梯

1

221232226.50kN 2

(10)重力荷载代表值汇总:G标准层=G楼面板+G纵梁+G横梁+G次梁+ G柱+G纵墙+ G横墙+G楼梯+Q1=6927.11kN

4.集中于各楼层高处的重力荷载代表值Gi的计算简图如下

6927.11KN

图4-1 各层重力荷载代表值

4.2横向框架在水平地震作用下的内力和位移计算

1.框架线刚度计算(前面已计算) 2.柱的侧移刚度D计算

(1)2-5层:D=(12974+22103)26=420924kN×m (2)首层:D=(5149+6778)26=143124kN×m 3.横向框架自振周期计算(计算过程见下表4-2)

表4-2

GU

i

i

10625.3 GiUi3532.85

由结构的自振周期公式T12T

式中:T--基本周期调整系数,考虑填充墙使框架自振周期减小,

取T=0.6(经验值)。

ui--各质点承受相当于其重力荷载代表值的水平节点力作

用时质点产生的侧移量。

所以T120.6

3532.85

0.692

10625.3

4.水平地震作用标准值和位移计算 (1)地震影响系数

本工程设防烈为七度,设计地震加速度为0.10g,由表3-4查得

amax=0.08,

0.9

类场地,设计地震分组为第一组,由表3-2查得Tg=0.35。

Tg

所以a1amax=0.043s

T1

又因为Tg=0.35s,T1=0.692s>1.4Tg=0.49s,所以得考虑地震作用系数n,

n=0.08T1+0.07=0.125。FEKa1G=0.0430.8532960.61=1204.70kN

按式(3-84)计算:FnnFEK=0.1251204.70=150.60kN (2)各质点水平地震作用标准值,楼层地震剪力及楼层层间位移计算 结构水平地震作用标准值按下式计算 Fi

GiHi

GH

ii1

n

FEK(1n)

i

各质点的水平地震作用标准值,楼层地震剪力及楼层间相对侧移量计算如下表4-3

表4-3

最大位移发生在的一层,其层间位移角e=



4.9582550

满足《建筑设计抗震规范》(GB50011-2010)第5.5.1条规定的位移限值[e]=1/550要求。 (3)剪重比验算

为了确保结构的安全与稳定,需进行结构剪重比的验算,具体如下表4-4

表4-4

4.3水平地震作用下框架内力计算

1.计算反弯点高度

表4-5 A、D轴柱的反弯点位置

表4-6 B、C轴柱的反弯点位置

表4-7 A、D轴柱框架柱剪力和梁柱端弯矩计算

表4-8 B、C轴柱框架柱剪力和梁柱端弯矩的计算

表4-9 各层框架柱轴力和各跨梁端剪力计算

3.绘制内力图 (1)弯矩图

图4-10横向框架在水平地震作用下的弯矩图

(2)剪力图

根据弯矩和剪力的关系,可采用隔离体方法计算剪力

A

B

FQ

绘制剪力图如下

MAMB

l

图4-11横向框架在水平地震作用下的剪力图

(3)轴力图

横向框架在水平地震作用下的柱的轴力就等于梁端传来的梁端剪力,横向框架在水平地震作用下的轴力图如下图所示。


相关文章

  • 2014最新土木工程毕业设计课题
  • 以下课题全套都有 太多不好找,可下载后打开按CTRL+F搜索关键词 5层5000m2办公楼设计 A0053土木工程毕业设计(论文)-青州卡特彼勒工业园广福寺路道路设计(含全套CAD A0090毕业设计(论文)-长沙市中医院办公楼及食堂中央空 ...查看


  • 混凝土框架结构开题报告
  • 毕业设计(论文)开题报告 题 目: 河北省某单位行政办公楼 开题报告填写要求 1.开题报告(含"文献综述")作为毕业设计(论文)答辩委员会对学生答辩资格审查的依据材料之一.此报告应在指导教师指导下,由学生在毕业设计(论文 ...查看


  • 框架结构毕业设计开题报告
  • 开题报告 题 目:朔州市政府办公楼建筑结构设计(框架结构 4) 文献综述: 填写说明:指根据研究内容查阅大量的参考文献,通过文献的阅读写清 该课题内容的国内外研究现状.基本研究方法.当前存在的 问题.发展动向,进而引出开展本设计(论文)研究 ...查看


  • 办公楼毕业设计调研报告
  • 毕业设计实习调研报告 结合毕业设计情况,根据实习调研的情况及所查阅的文献资料,撰写 3000 字以上的 报告: 一.前言: 调研人:XXX 调研时间:XXXXXXX 调研方式:实地考察.网上查询.资料收集 二.正文: 1.调研目的 了解办公 ...查看


  • 本科毕业设计_某科研办公楼框架结构设计
  • 本科毕业设计 某科研办公楼框架结构设计 摘要 摘要 本设计5层办公楼,总建筑面积约5467平方米.标准层高3.8米.主体采用框架结构体系,填充墙采用陶粒混凝土砌块墙,基础采用独立基础. 毕业设计目的是熟悉多层建筑结构设计的步骤,方法,掌握结 ...查看


  • 某8度抗震设防7层框架结构办公楼结构毕业设计
  • 设计题目为"某单位办公楼建筑结构设计"本设计包括以下资料 计算部分:1.全部计算书共165页 2. 开题报告 3. 目录摘要 4.设计任务书 图纸部分:包括建筑图和结构图共14张图纸 其中建筑图:1.标准层层平面图.dw ...查看


  • 大学综合行政办公楼设计论文
  • ***大学综合行政办公楼设计 年级:2003级 专业:土木工程 姓名:**** 指导老师:岳建伟 [摘要] 本工程为河南大学综合行政办公楼,建设地点位于开封市西郊,本结构安全等级为二级 ,耐火等级二级,抗震设防烈度7度. 本工程结构设计采用 ...查看


  • 框架结构文献综述
  • 框架结构设计 建筑是人类最早的生产活动之一,是在一定的历史条件下,随着社会生产力发展而形成发展的.由于经济的发展.土地的减少,现代建筑趋向于多高层建筑 [1],而砌体结构存在自重大.砌筑工作相当繁重.抗拉抗弯性能低.粘土砖用量很大,往往占用 ...查看


  • 土木工程专业毕业论文范文
  • 框架结构柱网尺寸的技术经济分析与确定原则 [摘要] 框架结构[1]具有很好的抗震性能,能够提供宽敞而灵活的使用空间,造价低廉.施 工方便,建筑造型的可塑空间大.在建筑设计中,只要选择了框架结构,就面临柱网尺寸如何确定的问题.框架结构柱网尺寸 ...查看


热门内容