土壤中重金属消解方法的比较

安徽农业科学,Journal

ofAnhui

Agn.Sci.2013,41(22):9259—9260

责任编辑刘月娟责任校对卢瑶

土壤中重金属消解方法的比较

蔺凯1,刘建利2,王舒婷2,马志鹏3

(1.西安市水环境监测中心,陕西西安710100;2.陕西省环境监测中心站,陕西西安710054;3.陕煤化集团陕化公司,陕西华县714100)

摘要[目的]通过采用3种土壤消解方法来对比各自的优缺点,为实验室操作选择合适方法。[方法]采用电热板加热消解、微波消解和全自动石墨消解3种方法对土壤标准样品GSS-8进行消解,通过测定样品中Cu、Pb、Ni3种重金属元素的含量对3种消解方法进行比较。[结果]电热板加热消解将土壤样品彻底消解;微波消解速度相对较快,密封消解避免了一些易挥发组分的损失,并且外源性污染少;全自动石墨消解方法按照步骤进行消解与结束。[结论]电热板加热消解是全量分解法,敞开系统;微波消解减少废酸、废气的排放,外源性污染少;全自动石墨消解步骤预先设定,按照程序消解,有效改变电热板加热对操作人员的危害。

关键词土壤;消解;测定中图分类号S181.3文献标识码A

文章编号0517—6611(2013)22—09259—02

ComparisonofDigestionMethodsofHeavyMetalsinSoil

LINKaietal(XianWaterEnvironmentalMonitoringCenter,Xian,Shaanxi710100)

Abstract[Objective]Respectiveadvantagesanddisadvantagesofthreekindsofsoildigestionmethododforthelaboperation

was

were

compared.And

suitablemeth—

digestedbythreekindsofmethodsofheatingelectricity—plate

digestion,microwavedigestionandgraphitedigestedautomaticmethod.Cu,PbandNiinthesampleweredeterminedtocomparethreekindsofdifferentmethods.[Result]Heatingelectricity—platedigestioncouldcompletelyeliminatesoilsamples.Microwavedigestionspeedwasrela—

was

chosen.[Method]SoilstandardsampleGSS一8

fast,andsealeddigestioncouldavoidthelossofsomevolatilecomponentsandexogenouspollutionwasless.Thedisintegrationofauto—

maticgraphitedigestionmethodshouldbecarriedoutinaccordancewiththestepsandend.[Conclusion]Heatingelectricity—platedigestionis

tively

thefullamountof

decompositionmethod,whichisanopensystem.Microwavedigestioncouldreduce

graphitedigestion’Sstep

was

set

waste

andacidemissions。exogenous

pollution

wasto

less.Atomaticoperators.

in

advance,according

to

theprogram,effectivelychangedtheelectricityplate

heatharm

Keywords

Soil;Digestion;Determine

环境监测中,常会检测土壤中重金属的含量。土壤中

含有的成分较多,有矿物质、有机质、水分以及空气等,因此

1.2土壤消解

1.2.1

电热板加热消解法。准确称取0.5000gGSS一8土壤

mlHCl

对土壤的消解尤为重要。比较常见的是电热板加热消解,使用盐酸、硝酸、氢氟酸、高氯酸等加热消解。由于电热板加热

消解是敞开式的加热,许多酸受热产生大量气体,加上操作人员要不时地操作,对试验人员身体有一定的危害¨。2-。

测定土壤样品中的重金属元素时,样品前处理是关键。

放人聚四氟乙烯坩埚内,用少量水润湿土样,加入10

摇匀加盖过夜,第2天放在电热板上,加热消解至3IIll左右,

加入5

ml

HNO,,再加热至3rIll左右,加入5

ml

ml

HF,摇荡20

min,再加入3HCl0。,加热赶酸至无白烟,土样变为灰白

色黏稠状,取下,冷却后转移至比色管内,定容至50rnl,摇匀后沉降,取上清液测定。

1.2.2

近年来,许多新的消解仪器被陆续推向市场,如微波消解仪、全自动石墨消解仪等。高利娟等¨1采用微波消解法研究了土壤样品中8种重金属的消解方法。Hsieh等H。采用微波的

方法测定污泥中的铜离子,发现微波消解不会对金属浓度产生影响。Hseu∞o用4种消解液对9种不同原料中的重金属进行分析检测,发现硝酸化处理方法对cd、Cr、Cu、Mn、Ni、Pb

微波加热消解法。准确称取0.5000gGSS一8土壤样HF和1

rnl

品于聚四氟乙烯消解罐内,加入5

mlHNO。4ml

H:0:,在微波消解仪中加热消解。微波消解程序见表1。然

后,于140℃赶酸2.5h,冷却,定容至50rnl,摇匀后沉降,取上清液测定。

表1

微波消解程序

和zn的效率最好。笔者将国家标准土壤样品GSS-8土壤分别采用电热板加热消解、微波消解与全自动石墨消解3种方法进行消解,比较3种处理方法对一些元素的影响。

1材料与方法1.1主要仪器与试剂

原子吸收分光光度计:SOLAAR

M6

型,美国热电;微波消解仪:ETH05T/Multiwave

3000,Multi・

1.2.30.50006060

wave;全自动石墨消解仪:DEENA,ThomasCain.INC。国家

土壤成分分析标准物质GBW07408(GSS一8)。所用试剂均为优级纯,试验用水经Milli-Q

Advantage

全自动石墨加热消解法。准确称取GSS一8土壤样品g于聚四氟乙烯消解罐内,首先加入10

ml

HCl,振荡

AIO处理。

S,130℃加热40min,冷却5min后,加入5S,130℃加热60min,冷却5min后,加入5

mlml

HNO,,振荡HF,摇荡60

llll

作者简介

蔺凯(1983一),男,陕西西安人,助理工程师,硕士,从事环境监测工作,E-mail:linkaill04@163.com。

S,130

oC加热10min,振荡60S,冷却5min;再加入3

HCl0。,振荡608;160℃加热100min,冷却至室温,定容至50

收稿日期2013-07-24

rnl,摇匀后沉降,取上清液测定。

万方数据

9260

安徽农业科学

2013生

1.3测定方法铜、铅的测定采用火焰原子吸收分光光度

法,GB/T7475—1987;Ni的测定采用火焰原子吸收分光光度法,GB/T

11912.1989。

2结果与分析

火焰原子吸收分光光度计的试验条件如表2所示。按照“1.3”中的方法,分别对3种消解样品进行分析。各元素的线性方程和线性相关系数见表3。

表2火焰原子吸收分光光度计的试验条件

对3种消解样品进行分析。从表4可以看出,用电热板加热消解的效果相对较好,原因为电热板消解方法传统,方法相对成熟。但是,电热板加热会导致酸和热量的流失。为

此,在消解过程中需不时地加酸,造成试剂的浪费,导致试验

时间的延长,同时试验过程需人工控制,操作较复杂【6

o。

表4各组试样测定结果

元素标准值

/um

紫堂判断

,.U-gl

直鎏

吸光值测定值平均值堡准

(生2坚型堑

竺芝丝堡董!型堑

消解0.0296

23.90.0295

23.8微波消解0.024

19.519.6

O.42

0.025320.10.0243

19.3全自动石0.025

520.319.8

0.45

墨消解0.024

19.40.0249

19.8Pb

电热板0.017222.422.8

0.36

21.0±2.0

消解0.0176

23.10.0175

22.9微波消解0.017322.521.9

O.56

、/

消解0.0166

21.40.0168

21.8全自动石0.016521.220.0

1.06

、/

墨消解0.015

19.20.0155

19.6Ni

电热板0.031229.629.9

0.74

31.5±1.8

、/

消解0.0309

29.30.0324

30.7微波消解0.031

30.229.4

O.67

0.030729.1O.0306

29.O全自动石Q.031

329.729.8

O.5l

墨消解

m0321

30.40.03l0

29.4

注:“、/”表示测定值在标准值范围内;“J”表示测定值比标准值低。

微波消解铅含量效果较好,铜、镍结果相对偏低,可能原

因是消解不彻底。这是由于土壤中存在大量的硅,一部分重

万方数据

金属元素存在于矿物晶格中,不易释放出来。加酸时间和加酸量对消解结果又会有一定的影响。张军国¨1用HN03-HF-HCIO。,梯度升压微波消解样品,采用原子荧光法测定水样中的砷、汞含量,发现准确度、精密度均较好。因此,对微波消

解应适当增加消解时间来保证样品消解完全,且在赶酸转移时防止损失。Esen等坤1用硝酸、盐酸、氢氟酸混合消解液,通过微波消解海底沉积物,发现效果较好。

全自动石墨消解镍、铅含量较好,铜结果偏低。原因同

样为条件设置不够,需在加氢氟酸后适当增加消解时间和振

荡次数。因电热板加热时,操作人员可以目视消解液,根据

状况增加消解液用量,并控制消解时间。但是,全自动石墨消解方法预先设定,仪器按照步骤进行消解,消解中可设定自动振荡,按设定程序结束消解,有效改变电热板加热对操

作人员身体的危害。3结论与讨论

电热板加热消解是全量分解法,将土壤样品彻底消解,

其中硝酸主要用于分解试样中的有机物质,和盐酸配比可提高分解效果。氢氟酸往往与其他酸一起用于分解含硅及硅

酸盐的样品,易使金属元素从矿物晶格中溶出。高氯酸是极

强的氧化剂,可完全分解有机物及有机质分解时产生的碳,同时可用于除去过多的氢氟酸,但高氯酸含杂质量比前2种酸略高。由于电热板全量分解法耗酸较多,使用量可视样品

消解程度随时添加,消解结果相对较好一1。

微波消解速度相对较快,酸用量小,减少了废酸、废气的排放,密封消化避免了一些易挥发组分的损失,并且外源性污染少,适合于有机质含量高、较难消解的样品,但是其消解时间较短,且称样量、加酸量都有一定的限制,可能产生消解

不完全,测定结果稍偏低,可增加消解时间改进条件。

全自动石墨消解仪同样为敞开体系,但其相对自动化,消解、赶酸、定容一站式处理,无需人工干预,且消解条件相对较易摸索,消解终点较易判断,易得到较好的结果。

参考文献

[1]王京文,徐文,周航,等.土壤样品中重金属消解方法的探讨[J].浙江

农业科学,2007,19(2):223—225.

[2]黄智伟,王宪,邱海源,等.土壤重金属含量的微波法与电热板消解法

测定的应用比较[J].厦门大学学报:自然科学版,2007,46(Z1):103—

106.

[3]高利娟,刘善江,孙钦平,等.土壤样品重金属统一消解法的探讨[J].

安徽农业科学,2010,38(36):20693—20695.

[4]HSIEH

cH,LOSL,CHIUEHPT。eta1.Microwaveenhancedstabilization

ofheavymetalsludge[J].Journal

ofHazardous

Materials,2007(B139):

160—166.

[5]HSEUZY.Evaluating

heavy

metalcontentsinninecompostsusingfour

digestion

metheds[J].BioresourceTechnology,2004,95:53—59.

[6]黄智伟,王宪,邱晦源,等.土壤重金属含量的微波法与电热板消解法

测定的应用比较[J].厦门大学学报:自然科学版,2007,46(S1):103—

106.

[7]张军国.利用微波消解和原子荧光光度法同时测定水样中的砷、汞

[J].干旱环境监测,2002,16(4):201—202。247.

[8]ESENC,BALCIA.Applieationofmicrowave—assisteddigestiontotrace

heavymetaldeterminationinseasedimentsample[J].HacettepeJournalofBiologyandChemistry,2008。36(2):123~128.

[9]汪燕,徐洁.微波与电热板消解原子吸收法测定土壤中的铜[J].三峡

环境与生态,2010,3(3):29—31.

土壤中重金属消解方法的比较

作者:

作者单位:刊名:英文刊名:年,卷(期):被引用次数:

蔺凯, 刘建利, 王舒婷, 马志鹏

蔺凯(西安市水环境监测中心,陕西西安,710100), 刘建利,王舒婷(陕西省环境监测中心站,陕西西安,710054), 马志鹏(陕煤化集团陕化公司,陕西华县,714100)安徽农业科学

Journal of Anhui Agricultural Sciences2013(22)5次

1.王京文,徐文,周航,张莉丽 土壤样品中重金属消解方法的探讨[期刊论文]-浙江农业科学 2007(2)

2.黄智伟,王宪,邱海源,陈丽丹,曾敏 土壤重金属含量的微波法与电热板消解法测定的应用比较[期刊论文]-厦门大学学报(自然科学版) 2007(z1)

3.高利娟,刘善江,孙钦平,李吉进,刘本生 土壤样品重金属统一消解法的探讨[期刊论文]-安徽农业科学 2010(36)

4.Ching-Hong Hsieh;Shang-Lien Lo;Pei-Te Chiueh;Wen-Hui Kuan;Ching-Lung Chen Microwave enhanced stabilization ofheavy metal sludge[外文期刊] 2007(1)

5.Hseu ZY Evaluating heavy metal contents in nine composts using four digestion methods[外文期刊] 2004(1)

6.黄智伟,王宪,邱海源,陈丽丹,曾敏 土壤重金属含量的微波法与电热板消解法测定的应用比较[期刊论文]-厦门大学学报(自然科学版) 2007(z1)

7.张军国 利用微波消解和原子荧光光度法同时测定水样中的砷、汞[期刊论文]-干旱环境监测 2002(4)

8.ESEN C;BALCI A Application of microwave-assisted digestion to trace heavy metal determination in sea sedimentsample 2008(02)

9.汪燕,徐洁 微波与电热板消解原子吸收法测定土壤中的铜[期刊论文]-三峡环境与生态 2010(3)

1.卢邦俊,方军毅 火焰原子吸收分光光度法测定土壤中铬的前处理方法探讨[期刊论文]-安徽农业科学 2014(22)2.苏补拽,马建疆 常规消解与微波消解前处理方法测定土壤中重金属比较分析[期刊论文]-内蒙古石油化工 2015(05)3.魏向利,雷用东,马小宁,王静,赵泽 微波消解-AAS法测定土壤中铅铬镉元素的研究[期刊论文]-安徽农业科学 2014(11)

引用本文格式:蔺凯.刘建利.王舒婷.马志鹏 土壤中重金属消解方法的比较[期刊论文]-安徽农业科学 2013(22)

安徽农业科学,Journal

ofAnhui

Agn.Sci.2013,41(22):9259—9260

责任编辑刘月娟责任校对卢瑶

土壤中重金属消解方法的比较

蔺凯1,刘建利2,王舒婷2,马志鹏3

(1.西安市水环境监测中心,陕西西安710100;2.陕西省环境监测中心站,陕西西安710054;3.陕煤化集团陕化公司,陕西华县714100)

摘要[目的]通过采用3种土壤消解方法来对比各自的优缺点,为实验室操作选择合适方法。[方法]采用电热板加热消解、微波消解和全自动石墨消解3种方法对土壤标准样品GSS-8进行消解,通过测定样品中Cu、Pb、Ni3种重金属元素的含量对3种消解方法进行比较。[结果]电热板加热消解将土壤样品彻底消解;微波消解速度相对较快,密封消解避免了一些易挥发组分的损失,并且外源性污染少;全自动石墨消解方法按照步骤进行消解与结束。[结论]电热板加热消解是全量分解法,敞开系统;微波消解减少废酸、废气的排放,外源性污染少;全自动石墨消解步骤预先设定,按照程序消解,有效改变电热板加热对操作人员的危害。

关键词土壤;消解;测定中图分类号S181.3文献标识码A

文章编号0517—6611(2013)22—09259—02

ComparisonofDigestionMethodsofHeavyMetalsinSoil

LINKaietal(XianWaterEnvironmentalMonitoringCenter,Xian,Shaanxi710100)

Abstract[Objective]Respectiveadvantagesanddisadvantagesofthreekindsofsoildigestionmethododforthelaboperation

was

were

compared.And

suitablemeth—

digestedbythreekindsofmethodsofheatingelectricity—plate

digestion,microwavedigestionandgraphitedigestedautomaticmethod.Cu,PbandNiinthesampleweredeterminedtocomparethreekindsofdifferentmethods.[Result]Heatingelectricity—platedigestioncouldcompletelyeliminatesoilsamples.Microwavedigestionspeedwasrela—

was

chosen.[Method]SoilstandardsampleGSS一8

fast,andsealeddigestioncouldavoidthelossofsomevolatilecomponentsandexogenouspollutionwasless.Thedisintegrationofauto—

maticgraphitedigestionmethodshouldbecarriedoutinaccordancewiththestepsandend.[Conclusion]Heatingelectricity—platedigestionis

tively

thefullamountof

decompositionmethod,whichisanopensystem.Microwavedigestioncouldreduce

graphitedigestion’Sstep

was

set

waste

andacidemissions。exogenous

pollution

wasto

less.Atomaticoperators.

in

advance,according

to

theprogram,effectivelychangedtheelectricityplate

heatharm

Keywords

Soil;Digestion;Determine

环境监测中,常会检测土壤中重金属的含量。土壤中

含有的成分较多,有矿物质、有机质、水分以及空气等,因此

1.2土壤消解

1.2.1

电热板加热消解法。准确称取0.5000gGSS一8土壤

mlHCl

对土壤的消解尤为重要。比较常见的是电热板加热消解,使用盐酸、硝酸、氢氟酸、高氯酸等加热消解。由于电热板加热

消解是敞开式的加热,许多酸受热产生大量气体,加上操作人员要不时地操作,对试验人员身体有一定的危害¨。2-。

测定土壤样品中的重金属元素时,样品前处理是关键。

放人聚四氟乙烯坩埚内,用少量水润湿土样,加入10

摇匀加盖过夜,第2天放在电热板上,加热消解至3IIll左右,

加入5

ml

HNO,,再加热至3rIll左右,加入5

ml

ml

HF,摇荡20

min,再加入3HCl0。,加热赶酸至无白烟,土样变为灰白

色黏稠状,取下,冷却后转移至比色管内,定容至50rnl,摇匀后沉降,取上清液测定。

1.2.2

近年来,许多新的消解仪器被陆续推向市场,如微波消解仪、全自动石墨消解仪等。高利娟等¨1采用微波消解法研究了土壤样品中8种重金属的消解方法。Hsieh等H。采用微波的

方法测定污泥中的铜离子,发现微波消解不会对金属浓度产生影响。Hseu∞o用4种消解液对9种不同原料中的重金属进行分析检测,发现硝酸化处理方法对cd、Cr、Cu、Mn、Ni、Pb

微波加热消解法。准确称取0.5000gGSS一8土壤样HF和1

rnl

品于聚四氟乙烯消解罐内,加入5

mlHNO。4ml

H:0:,在微波消解仪中加热消解。微波消解程序见表1。然

后,于140℃赶酸2.5h,冷却,定容至50rnl,摇匀后沉降,取上清液测定。

表1

微波消解程序

和zn的效率最好。笔者将国家标准土壤样品GSS-8土壤分别采用电热板加热消解、微波消解与全自动石墨消解3种方法进行消解,比较3种处理方法对一些元素的影响。

1材料与方法1.1主要仪器与试剂

原子吸收分光光度计:SOLAAR

M6

型,美国热电;微波消解仪:ETH05T/Multiwave

3000,Multi・

1.2.30.50006060

wave;全自动石墨消解仪:DEENA,ThomasCain.INC。国家

土壤成分分析标准物质GBW07408(GSS一8)。所用试剂均为优级纯,试验用水经Milli-Q

Advantage

全自动石墨加热消解法。准确称取GSS一8土壤样品g于聚四氟乙烯消解罐内,首先加入10

ml

HCl,振荡

AIO处理。

S,130℃加热40min,冷却5min后,加入5S,130℃加热60min,冷却5min后,加入5

mlml

HNO,,振荡HF,摇荡60

llll

作者简介

蔺凯(1983一),男,陕西西安人,助理工程师,硕士,从事环境监测工作,E-mail:linkaill04@163.com。

S,130

oC加热10min,振荡60S,冷却5min;再加入3

HCl0。,振荡608;160℃加热100min,冷却至室温,定容至50

收稿日期2013-07-24

rnl,摇匀后沉降,取上清液测定。

万方数据

9260

安徽农业科学

2013生

1.3测定方法铜、铅的测定采用火焰原子吸收分光光度

法,GB/T7475—1987;Ni的测定采用火焰原子吸收分光光度法,GB/T

11912.1989。

2结果与分析

火焰原子吸收分光光度计的试验条件如表2所示。按照“1.3”中的方法,分别对3种消解样品进行分析。各元素的线性方程和线性相关系数见表3。

表2火焰原子吸收分光光度计的试验条件

对3种消解样品进行分析。从表4可以看出,用电热板加热消解的效果相对较好,原因为电热板消解方法传统,方法相对成熟。但是,电热板加热会导致酸和热量的流失。为

此,在消解过程中需不时地加酸,造成试剂的浪费,导致试验

时间的延长,同时试验过程需人工控制,操作较复杂【6

o。

表4各组试样测定结果

元素标准值

/um

紫堂判断

,.U-gl

直鎏

吸光值测定值平均值堡准

(生2坚型堑

竺芝丝堡董!型堑

消解0.0296

23.90.0295

23.8微波消解0.024

19.519.6

O.42

0.025320.10.0243

19.3全自动石0.025

520.319.8

0.45

墨消解0.024

19.40.0249

19.8Pb

电热板0.017222.422.8

0.36

21.0±2.0

消解0.0176

23.10.0175

22.9微波消解0.017322.521.9

O.56

、/

消解0.0166

21.40.0168

21.8全自动石0.016521.220.0

1.06

、/

墨消解0.015

19.20.0155

19.6Ni

电热板0.031229.629.9

0.74

31.5±1.8

、/

消解0.0309

29.30.0324

30.7微波消解0.031

30.229.4

O.67

0.030729.1O.0306

29.O全自动石Q.031

329.729.8

O.5l

墨消解

m0321

30.40.03l0

29.4

注:“、/”表示测定值在标准值范围内;“J”表示测定值比标准值低。

微波消解铅含量效果较好,铜、镍结果相对偏低,可能原

因是消解不彻底。这是由于土壤中存在大量的硅,一部分重

万方数据

金属元素存在于矿物晶格中,不易释放出来。加酸时间和加酸量对消解结果又会有一定的影响。张军国¨1用HN03-HF-HCIO。,梯度升压微波消解样品,采用原子荧光法测定水样中的砷、汞含量,发现准确度、精密度均较好。因此,对微波消

解应适当增加消解时间来保证样品消解完全,且在赶酸转移时防止损失。Esen等坤1用硝酸、盐酸、氢氟酸混合消解液,通过微波消解海底沉积物,发现效果较好。

全自动石墨消解镍、铅含量较好,铜结果偏低。原因同

样为条件设置不够,需在加氢氟酸后适当增加消解时间和振

荡次数。因电热板加热时,操作人员可以目视消解液,根据

状况增加消解液用量,并控制消解时间。但是,全自动石墨消解方法预先设定,仪器按照步骤进行消解,消解中可设定自动振荡,按设定程序结束消解,有效改变电热板加热对操

作人员身体的危害。3结论与讨论

电热板加热消解是全量分解法,将土壤样品彻底消解,

其中硝酸主要用于分解试样中的有机物质,和盐酸配比可提高分解效果。氢氟酸往往与其他酸一起用于分解含硅及硅

酸盐的样品,易使金属元素从矿物晶格中溶出。高氯酸是极

强的氧化剂,可完全分解有机物及有机质分解时产生的碳,同时可用于除去过多的氢氟酸,但高氯酸含杂质量比前2种酸略高。由于电热板全量分解法耗酸较多,使用量可视样品

消解程度随时添加,消解结果相对较好一1。

微波消解速度相对较快,酸用量小,减少了废酸、废气的排放,密封消化避免了一些易挥发组分的损失,并且外源性污染少,适合于有机质含量高、较难消解的样品,但是其消解时间较短,且称样量、加酸量都有一定的限制,可能产生消解

不完全,测定结果稍偏低,可增加消解时间改进条件。

全自动石墨消解仪同样为敞开体系,但其相对自动化,消解、赶酸、定容一站式处理,无需人工干预,且消解条件相对较易摸索,消解终点较易判断,易得到较好的结果。

参考文献

[1]王京文,徐文,周航,等.土壤样品中重金属消解方法的探讨[J].浙江

农业科学,2007,19(2):223—225.

[2]黄智伟,王宪,邱海源,等.土壤重金属含量的微波法与电热板消解法

测定的应用比较[J].厦门大学学报:自然科学版,2007,46(Z1):103—

106.

[3]高利娟,刘善江,孙钦平,等.土壤样品重金属统一消解法的探讨[J].

安徽农业科学,2010,38(36):20693—20695.

[4]HSIEH

cH,LOSL,CHIUEHPT。eta1.Microwaveenhancedstabilization

ofheavymetalsludge[J].Journal

ofHazardous

Materials,2007(B139):

160—166.

[5]HSEUZY.Evaluating

heavy

metalcontentsinninecompostsusingfour

digestion

metheds[J].BioresourceTechnology,2004,95:53—59.

[6]黄智伟,王宪,邱晦源,等.土壤重金属含量的微波法与电热板消解法

测定的应用比较[J].厦门大学学报:自然科学版,2007,46(S1):103—

106.

[7]张军国.利用微波消解和原子荧光光度法同时测定水样中的砷、汞

[J].干旱环境监测,2002,16(4):201—202。247.

[8]ESENC,BALCIA.Applieationofmicrowave—assisteddigestiontotrace

heavymetaldeterminationinseasedimentsample[J].HacettepeJournalofBiologyandChemistry,2008。36(2):123~128.

[9]汪燕,徐洁.微波与电热板消解原子吸收法测定土壤中的铜[J].三峡

环境与生态,2010,3(3):29—31.

土壤中重金属消解方法的比较

作者:

作者单位:刊名:英文刊名:年,卷(期):被引用次数:

蔺凯, 刘建利, 王舒婷, 马志鹏

蔺凯(西安市水环境监测中心,陕西西安,710100), 刘建利,王舒婷(陕西省环境监测中心站,陕西西安,710054), 马志鹏(陕煤化集团陕化公司,陕西华县,714100)安徽农业科学

Journal of Anhui Agricultural Sciences2013(22)5次

1.王京文,徐文,周航,张莉丽 土壤样品中重金属消解方法的探讨[期刊论文]-浙江农业科学 2007(2)

2.黄智伟,王宪,邱海源,陈丽丹,曾敏 土壤重金属含量的微波法与电热板消解法测定的应用比较[期刊论文]-厦门大学学报(自然科学版) 2007(z1)

3.高利娟,刘善江,孙钦平,李吉进,刘本生 土壤样品重金属统一消解法的探讨[期刊论文]-安徽农业科学 2010(36)

4.Ching-Hong Hsieh;Shang-Lien Lo;Pei-Te Chiueh;Wen-Hui Kuan;Ching-Lung Chen Microwave enhanced stabilization ofheavy metal sludge[外文期刊] 2007(1)

5.Hseu ZY Evaluating heavy metal contents in nine composts using four digestion methods[外文期刊] 2004(1)

6.黄智伟,王宪,邱海源,陈丽丹,曾敏 土壤重金属含量的微波法与电热板消解法测定的应用比较[期刊论文]-厦门大学学报(自然科学版) 2007(z1)

7.张军国 利用微波消解和原子荧光光度法同时测定水样中的砷、汞[期刊论文]-干旱环境监测 2002(4)

8.ESEN C;BALCI A Application of microwave-assisted digestion to trace heavy metal determination in sea sedimentsample 2008(02)

9.汪燕,徐洁 微波与电热板消解原子吸收法测定土壤中的铜[期刊论文]-三峡环境与生态 2010(3)

1.卢邦俊,方军毅 火焰原子吸收分光光度法测定土壤中铬的前处理方法探讨[期刊论文]-安徽农业科学 2014(22)2.苏补拽,马建疆 常规消解与微波消解前处理方法测定土壤中重金属比较分析[期刊论文]-内蒙古石油化工 2015(05)3.魏向利,雷用东,马小宁,王静,赵泽 微波消解-AAS法测定土壤中铅铬镉元素的研究[期刊论文]-安徽农业科学 2014(11)

引用本文格式:蔺凯.刘建利.王舒婷.马志鹏 土壤中重金属消解方法的比较[期刊论文]-安徽农业科学 2013(22)


相关文章

  • 土壤样品中重金属消解方法的探讨
  • 雾藿票涮善奄)蓁主耋耄h堂錾譬纛 薹錾瑟羹囊羹需蒌纛囊鬟需篓甏羹 §商":拍戥:薹瑁i趔霪霎 l羹鐾墓薹荤誊薹冀羹霉妻萋耋善羹,辇妻霎薹iiiiii: 鬟姜j薷受蕊霎萋薹巡■囊薹掌冀鬟叁雾熏霪蠢:妻:ij羹l薹:l:霎i要i::验 ...查看


  • 土壤样本的预处理
  • 土壤样本的预处理 . 称取1 g磨细土样于150Ⅱll 锥形瓶中,加入浓HNO 5 ml.浓HCI 15 ml,摇匀,置于电热板上,以低温加热分解.逐渐提高温度,当瓶中内容物激烈反应过后,取下锥形瓶,稍冷却,加入HC1 5 ml ,继续加热 ...查看


  • 土壤消解注意事项
  • 土壤湿法消解过程中需要注意的细节问题 严平川 1 前言 由于土壤结构的复杂性,要检测土壤的成分,特别是其中重金属元素的含量,必须进行消解.目前常用的消解方法有湿法.干灰化法和微波消解三种.国家标准(GB/T17138~17141-1997) ...查看


  • 污泥中重金属测定的前处理方法研究
  • 第12卷第1期2010年1月 大连民族学院学报 JournalofDalianNationalitiesUniversity V01.12,No.1 January2010 文章编号:1009-315X(2010}01-0093-01 污泥 ...查看


  • 污水处理厂重金属污染特点及潜在风险
  • 污水处理厂重金属污染特点及潜在风险 1 引言 污泥是污水处理过程中的必然产物,主要由多种菌胶团与其吸附的有机和无机物集合体所组成. 随着我国污水处理能力及处理率的快速增长,产生了大量剩余污泥,污泥处置将成为我国一个更加突出的实际环境问题. ...查看


  • 测定城市生活污泥中重金属的酸消解方法研究
  • 环境污染与防治 第26卷 第3期 2004年6月 测定城市生活污泥中重金属的酸消解方法研究 孙 颖 陈 玲 赵建夫 吕 彦 1 2 2 2 * (1. 上海大学环境与化学工程学院, 上海200072; 2. 同济大学污染控制与资源化研究国家 ...查看


  • 水中汞等重金属含量的检测
  • 水中汞等重金属含量检测的新方法 --东北师范大学,化学学院,胡志强,1231410011 [摘要] 近年来,由于重金属而受到污染的地区日益增多,受污染的程度日趋加重.因此,重金属开始成为人们关注的焦点.对于水中的重金属而言,由于不易被微生物 ...查看


  • 食品中的重金属铅与检测方法研究
  • 食品中的重金属铅与检测方法研究 摘要 本文主要归纳了食品中重金属铅的污染来源与其危害影响,针对现阶段对重金属的检测方法的研究与发展,例如火焰原子吸收光谱法.石墨炉原子吸收光谱法和原子荧光光谱法的原理和在使用仪器时的优点和缺点进行了分析研究, ...查看


  • 稻米镉测定国标方法的改进
  • 专论与镰述 中圈秘米20cr7年第3期 稻米镉测定国标方法的改进 陶曙华 (湖南省水稻研究所,湖南长沙410125) 摘要:通过选择用硝酸.硝酸+双氧水.不同比例的硝酸+高氯酸共5种消解剂对稻米标准样品进行消煮,用石墨炉原子吸收分光光度计测 ...查看


热门内容