几种茶叶中铝含量的测定

几种茶叶中铝含量的测定

张捷莉,王春光,苑 蕾,李学成,回瑞华,侯冬岩

(鞍山师范学院化学系,辽宁 鞍山 114007)

摘 要:本文尝试水杨基荧光酮作显色剂来测定茉莉花茶、苦丁茶和红茶三种常见茶叶的铝含量。在波长559nm 处,对浓度在0~5μg/(25ml)范围内的铝标准溶液的吸光度进行测定,结果表明其吸光度与浓度有良好的线性关系,标准工作曲线回归方程为C=0.2826A+0.0044,相关系数r=0.9992(n=5),回收率在93%~103%之间,标准偏差小于0.000242,变异系数小于0.65%,有较高的精密度。此法操作简单,精密度、回收率都较好,适用于测定茶叶中的铝含量。

关键词:铝;分光光度法;茶;水杨基荧光酮

Determination of the Aluminum in Several Teas

ZHANG Jie-li,WANG Chun-guang,YUAN Lei,LI Xue-cheng,HUI Rui-hua,HOU Dong-yan

(Chemistry Department, Anshan Normal University, Anshan 114007, China)

Abstract : In this article, the salicyl fluorescence alkone is used as color reagent to determine the contents of the aluminum in jasmine tea, kuding tea and black tea. The calibration curve is figured by determining the standard aluminum solution at 559nm. The content of the standard solution is from 0 to 5μg/25ml. The regression equation is C=0.2826A+0.0044, correlation coefficient r=0.9992(n=5), the recovery is from 93% to 103%. The standard deviation is 0.000242, and variation coefficient is less than 0.65%. This method, for the determination of content of aluminum in teas is simple, and the accuracy and the recovery are satisfied. The method is suitable to determinate the content of aluminum.

Key words:aluminum ;spectrophotometry ;tea ;salicyl fluorescence alkone

中图分类号:TS207.51 文献标识码:A 文章编号: 1002-6630(2006)12-0688-03

铝对人体的危害已有大量研究显示,铝是一种对人体健康有害的元素,可在人体内蓄积并产生慢性毒性。体内过多的铝对人体的中枢神经系统、脑、肝、骨、肾、细胞、造血系统、人体免疫功能、胚胎等均有不良影响[1]。茶是一种铝蓄积植物,我国是茶叶大国,茶叶种类多种多样。茶叶中铝含量的测定方法很多,如石墨炉原子吸收光度法、荧光分析法、极谱法等。本文采用分光光度法,以水杨基荧光酮为显色剂,溴化十六烷基三甲胺为增敏剂,在氨-氯化铵缓冲溶液(pH=10)中使铝与显色剂反应,通过测定其吸光度值再根据标准工作曲线得出其含量。该方法操作简单,精密度、回收率较好,适用于茶叶中铝含量的测定。11. 1

材料与方法仪器与试药

TU-1201型紫外分光光度计 北京普析通用仪器有

限责任公司;LAC 214型电子分析天平 中国轻工业机械总公司常熟衡器工业公司;766-2型远红外辐射干燥箱 上海阳光仪器有限公司;SX2高效节能炉 武汉华中工学院制冷设备厂;KWS 温度控制器 武汉华中工学院制冷设备厂;铝片(高纯) 天津市光复精细化工研究所;盐酸(分析纯) 沈阳化学试剂厂;氢氧化钠(分析纯) 沈阳市试剂二厂;氨水(分析纯) 沈阳化学试剂厂;氯化铵(分析纯) 天津市光复精细化工研究所;溴化十六烷基三甲胺(分析纯) 天津市化学试剂研究所;水杨基荧光酮(分析纯) 天津市化学试剂研究所;抗坏血酸 东北制药总厂一分厂。1. 2

溶液配制

铝标准贮备液:称取高纯铝0.5000g 于塑料杯中,加入20%氢氧化钠溶液5m l ,在热水浴中加热溶解,用水稀释至50ml ,用1:1盐酸酸化,并过量2~3ml ,移入500m l 容量瓶中,用水稀释至刻度。此溶液每m l 含

收稿日期:2006-07-21

作者简介:张捷莉(1954-) ,女,高级实验师,主要从事食品及药品成分的分析工作。

铝1.000mg 。

铝标准使用液:吸取1.00ml 铝标准贮备液置于100ml 容量瓶中,用水稀释至刻度,再从中吸取5.00ml 于50ml 容量瓶中,用水稀释至刻度。此溶液每毫升含1μg 铝。

水杨基荧光酮(SAF):1×10

-3

m o l /L 。称取S A F

67.24mg 于小烧杯中,用50ml 无水乙醇溶解,并用无水乙醇定容至200m l ,混匀,盛于棕色瓶中保存。

溴化十六烷基三甲胺(C T M A B ) :3%水溶液。氨-氯化铵缓冲溶液:p H 10。抗坏血酸:1%水溶液。1. 3

样品

茉莉花茶(产于福建) ;苦丁茶(产于贵州) ;红茶(产于云南) 。1. 4

茶叶样品中Al 3+的提取

将茶叶样品置于60℃的烘箱中烘干4h 后,粉碎研成粉末。准确称取粉末状的茶叶样品0.25g 左右于瓷坩埚中,在煤气灯上炭化后转入550℃马弗炉中灼烧4h ,取出冷却后用0.5ml(1:1)盐酸溶解残渣,然后转入100ml 容量瓶定容,摇匀备用。移取上述试样10.00ml 于50ml 容量瓶中,加入1%抗坏血酸1.00ml 以掩蔽铁离子,加水定容,摇匀备用[2]

1. 5条件实验

1. 5. 1

最大吸收波长的选择

向盛有3.00ml 铝标准使用液(1.0μg/ ml)的25ml 比色管中,依次加入氨-氯化铵缓冲溶液1.00ml 、3% CTMAB溶液3.00ml 、1×10-3mol/L SAF溶液0.50ml ,加水稀释

至刻度,摇匀。静置30m i n 后,以试剂空白作参比,用1cm 比色杯测定其在不同波长下的吸光度,做出吸收曲线。结果表明Al(III)-SAF-CTMAB配合物在559nm 处有最大吸收,故选择559n m 为测定波长[3]。1. 5. 2

Fe 3+

对样品测定的影响

茶叶在制备过程中一般需要用铁锅炒干,因而其大多含有一定量的Fe 3+

。有相关文献记载当样品中Fe 3+

含量为 Al3+含量的5倍以上将对Al 3+的测定产生干扰。在4个25ml 容量瓶中各加入2.00ml 铝标准液(含Al 3+ 2μg) ;再分别加入浓度为2μg/ml的 Fe3+溶液0.00、3.00、5.00、7.00ml(即Fe 3+含量分别为Al 3+的0、3、5、7倍) ;以空白作参比分别测定其吸光度,后三者与第一个未加Fe 3+的作比较,发现加Fe 3+的比没加Fe 3+的溶液的吸光度值要低。如表1所示。当Fe 3+的含量为Al 3+的3倍时,吸光度值已有微小变化,当达到5倍时吸光度值已有明显不同,7倍时变化更大。说明对于此测定方法,3倍于Al 3+含量的Fe 3+已对测定结果产生干扰。本实验采用加入1%抗坏血酸以掩蔽此干扰。1. 5. 3

标准工作曲线的绘制

表1 Fe 3+的干扰

Tabel 1 Interference from Fe3+

Fe 3+体积(ml)

A B S 三次测定值A B S 平均值0.000.2566~0.25750.25713.000.2472~0.25310.25035.000.1856~0.18830.18697.00

0.1350~0.1375

0.1365

分别取0.00~5.00ml(1.0μg/ml)铝标准使用液置于25ml 比色管中,依次加入氨-氯化铵缓冲溶液1. 00m l 、3%CTMAB 溶液3.00ml 、1×10-3mol/L SAF溶液0.50ml ,加水稀释至刻度,摇匀。静置30m i n 后,以试剂空白作参比,在559nm 处分别测定不同浓度的吸光度并绘制出工作曲线(见图1) [3]。

A

浓度(μg/ml)

图1 标准工作曲线Fig.1 Standard curve

根据测得的标准工作曲线得回归方程为C=0.2826A+0.0044,相关系数r=0.9992,说明在波长559nm 处对浓度在0~5μg/(25ml)范围内的铝标准溶液的吸光度进行测定,其吸光度与浓度有良好的线性关系,可按此标准工作曲线进行定量测定。1. 5. 4

方法精密度实验

为了评价所用方法的精密度,根据前面的测试条件,取5个不同浓度的样品,在测定波长下测定其吸光度,结果见表2。

表2 方法精密度

Table 2 Precise of the method

样品取样浓度九次测定值平均值标准偏差变异系数编号(μg/ml)(μg/ml)(μg/ml)(μg/ml)(%)10.0400.0336~0.03420.03380.0002200.6520.0800.0721~0.07260.07230.0001780.2530.1200.1102~0.11090.11060.0002420.2240.1600.1717~0.17190.17180.0000770.055

0.200

0.2061~0.2067

0.2065

0.000197

0.10

由表2可知,标准偏差小于0.000242,变动系数小于0. 65%,表明精密度较高。

1. 5. 5

稳定性实验

分别取三种茶叶样品提取液茉莉花茶5.00ml 、苦丁

表4 茶叶样品中Al 3+含量的测定结果Table 4 Contents of the Al3+ in teas

茶5.00ml 、红茶3.00ml 于三个25ml 比色管中,依次加入氨-氯化铵缓冲溶液1.00ml 、3% CTMAB 溶液3.00ml 、1×10-3mol/L SAF溶液0.50ml ,加水稀释至刻度,摇匀。静置30m i n 后,以试剂空白作参比进行时间扫描。结果表明,三种样品的提取液在2h 内都具有良好的稳定性。1. 5. 61. 5. 7

回收率的测定

几种茶中Al 含量的回收率实验

3+

样品名称莉花茶苦丁茶红茶

Al 3+的三次测定值(μg/g)

802.7~915.7717.9~730.01622.5~1811.5

平均值(mg/kg)

856.6722.41724.7

甲胺的存在下,在氨-氯化铵缓冲溶液(pH10)中,使铝与水杨基荧光酮发生显色反应。此法相对于前者有较高的灵敏度,故本实验采用此法进行测定。

由表1可以看出,针对本测定方法,3倍以上的Fe 3+

即可对Al 3+含量的测定产生干扰。故在对茶叶样品中的铝进行提取后,加入1ml 1%的抗坏血酸溶液掩蔽此干扰,以保证测定结果的准确性。

由图1可知,Al 3+在0~5μg/(25ml)范围内,其浓度与吸光度具有良好的线性关系;由表2~4可知,该测定方法的精密度、回收率都较好,说明该法测定结果可靠。

由表4可知,三种茶样中A l 3+的含量由高到低依次为红茶、茉莉花茶、苦丁茶。国家有相关规定,人体铝的暂定摄入量标准为7m g /k g 。虽然测定的三种茶叶中铝含量远远大于该标准,但因泡茶过程中铝的溶出量有20%损失且饮茶后人体对铝的吸收量占摄入量的0. 5%,故正常饮用此三种茶叶并不会威胁人体健康。

对于本实验测定的三种茶叶,有材料显示曾有人做过同名茶叶的铝含量测定,但与本实验所用显色剂不同。有文献记载,已有用本实验所用显色剂测定膨化食品中铝含量的研究,而对其用于茶叶中铝含量测定尚无记载。

参考文献:

[1][2][3]

张加玲, 刘桂英. 铝对人体的危害、铝的来源及测定方法研究进展[J]. 临床医药实践杂志, 2005, 14(1): 3-6.

韩兰英, 徐荷香, 汪英兰, 等. Al-CAS-CTMAB-OP显色反应的研究[J]. 上饶师范学院学报, 2004, 24(6): 61.

王爱月, 杨新玲, 李漫男. 分光光度法测定食品中微量铝-Al(III)-SAF-CTMAB 体系[J]. 郑州粮食学院学报, 1998, (3): 15-17.

取7个25ml 的比色管,从茉莉花茶样品提取液中吸取3.50、4.50、5.50ml 于三个比色管中;再向另三个比色管中加入相同体积的样品液,然后分别加入1ml Al标准使用液。向此7个比色管中依次加入氨-氯化铵缓冲溶液1.00ml 、3% CTMAB 溶液3.00ml 、1×10mol/L

-3

SAF 溶液0.50ml ,加水稀释至刻度,摇匀。静置30min 后,以试剂空白作参比,在559n m 处,在标准曲线项下测定其对应浓度。结果见表3。

表3 茉莉花茶回收率实验结果

Table 3 Recovery of determining jasmine tea with the method加标前(μg/ml)

0.06410.07670.0883

加标量(μg/ml)

0.0400.0400.040

实测值(μg/ml)

0.10160.11660.1278

回收率(%)

9410099

按此方法进行苦丁茶及红茶中Al 3+含量的回收率实验,其结果表明其回收率均在93%~103%之间表明准确性较高。1. 6

茶叶样品中Al 3+含量的测定

按照回收率实验的方法分别对茉莉花茶、苦丁茶、红茶三种样品的Al 3+提取液进行取样并测定。测定结果见表4。2

讨 论

目前,在测定食品中铝含量的分光光度法中以铬天青s 比色法最为常用。而本实验选择在溴化十六烷基三

中文核心期刊

百种中国杰出学术期刊

几种茶叶中铝含量的测定

张捷莉,王春光,苑 蕾,李学成,回瑞华,侯冬岩

(鞍山师范学院化学系,辽宁 鞍山 114007)

摘 要:本文尝试水杨基荧光酮作显色剂来测定茉莉花茶、苦丁茶和红茶三种常见茶叶的铝含量。在波长559nm 处,对浓度在0~5μg/(25ml)范围内的铝标准溶液的吸光度进行测定,结果表明其吸光度与浓度有良好的线性关系,标准工作曲线回归方程为C=0.2826A+0.0044,相关系数r=0.9992(n=5),回收率在93%~103%之间,标准偏差小于0.000242,变异系数小于0.65%,有较高的精密度。此法操作简单,精密度、回收率都较好,适用于测定茶叶中的铝含量。

关键词:铝;分光光度法;茶;水杨基荧光酮

Determination of the Aluminum in Several Teas

ZHANG Jie-li,WANG Chun-guang,YUAN Lei,LI Xue-cheng,HUI Rui-hua,HOU Dong-yan

(Chemistry Department, Anshan Normal University, Anshan 114007, China)

Abstract : In this article, the salicyl fluorescence alkone is used as color reagent to determine the contents of the aluminum in jasmine tea, kuding tea and black tea. The calibration curve is figured by determining the standard aluminum solution at 559nm. The content of the standard solution is from 0 to 5μg/25ml. The regression equation is C=0.2826A+0.0044, correlation coefficient r=0.9992(n=5), the recovery is from 93% to 103%. The standard deviation is 0.000242, and variation coefficient is less than 0.65%. This method, for the determination of content of aluminum in teas is simple, and the accuracy and the recovery are satisfied. The method is suitable to determinate the content of aluminum.

Key words:aluminum ;spectrophotometry ;tea ;salicyl fluorescence alkone

中图分类号:TS207.51 文献标识码:A 文章编号: 1002-6630(2006)12-0688-03

铝对人体的危害已有大量研究显示,铝是一种对人体健康有害的元素,可在人体内蓄积并产生慢性毒性。体内过多的铝对人体的中枢神经系统、脑、肝、骨、肾、细胞、造血系统、人体免疫功能、胚胎等均有不良影响[1]。茶是一种铝蓄积植物,我国是茶叶大国,茶叶种类多种多样。茶叶中铝含量的测定方法很多,如石墨炉原子吸收光度法、荧光分析法、极谱法等。本文采用分光光度法,以水杨基荧光酮为显色剂,溴化十六烷基三甲胺为增敏剂,在氨-氯化铵缓冲溶液(pH=10)中使铝与显色剂反应,通过测定其吸光度值再根据标准工作曲线得出其含量。该方法操作简单,精密度、回收率较好,适用于茶叶中铝含量的测定。11. 1

材料与方法仪器与试药

TU-1201型紫外分光光度计 北京普析通用仪器有

限责任公司;LAC 214型电子分析天平 中国轻工业机械总公司常熟衡器工业公司;766-2型远红外辐射干燥箱 上海阳光仪器有限公司;SX2高效节能炉 武汉华中工学院制冷设备厂;KWS 温度控制器 武汉华中工学院制冷设备厂;铝片(高纯) 天津市光复精细化工研究所;盐酸(分析纯) 沈阳化学试剂厂;氢氧化钠(分析纯) 沈阳市试剂二厂;氨水(分析纯) 沈阳化学试剂厂;氯化铵(分析纯) 天津市光复精细化工研究所;溴化十六烷基三甲胺(分析纯) 天津市化学试剂研究所;水杨基荧光酮(分析纯) 天津市化学试剂研究所;抗坏血酸 东北制药总厂一分厂。1. 2

溶液配制

铝标准贮备液:称取高纯铝0.5000g 于塑料杯中,加入20%氢氧化钠溶液5m l ,在热水浴中加热溶解,用水稀释至50ml ,用1:1盐酸酸化,并过量2~3ml ,移入500m l 容量瓶中,用水稀释至刻度。此溶液每m l 含

收稿日期:2006-07-21

作者简介:张捷莉(1954-) ,女,高级实验师,主要从事食品及药品成分的分析工作。

铝1.000mg 。

铝标准使用液:吸取1.00ml 铝标准贮备液置于100ml 容量瓶中,用水稀释至刻度,再从中吸取5.00ml 于50ml 容量瓶中,用水稀释至刻度。此溶液每毫升含1μg 铝。

水杨基荧光酮(SAF):1×10

-3

m o l /L 。称取S A F

67.24mg 于小烧杯中,用50ml 无水乙醇溶解,并用无水乙醇定容至200m l ,混匀,盛于棕色瓶中保存。

溴化十六烷基三甲胺(C T M A B ) :3%水溶液。氨-氯化铵缓冲溶液:p H 10。抗坏血酸:1%水溶液。1. 3

样品

茉莉花茶(产于福建) ;苦丁茶(产于贵州) ;红茶(产于云南) 。1. 4

茶叶样品中Al 3+的提取

将茶叶样品置于60℃的烘箱中烘干4h 后,粉碎研成粉末。准确称取粉末状的茶叶样品0.25g 左右于瓷坩埚中,在煤气灯上炭化后转入550℃马弗炉中灼烧4h ,取出冷却后用0.5ml(1:1)盐酸溶解残渣,然后转入100ml 容量瓶定容,摇匀备用。移取上述试样10.00ml 于50ml 容量瓶中,加入1%抗坏血酸1.00ml 以掩蔽铁离子,加水定容,摇匀备用[2]

1. 5条件实验

1. 5. 1

最大吸收波长的选择

向盛有3.00ml 铝标准使用液(1.0μg/ ml)的25ml 比色管中,依次加入氨-氯化铵缓冲溶液1.00ml 、3% CTMAB溶液3.00ml 、1×10-3mol/L SAF溶液0.50ml ,加水稀释

至刻度,摇匀。静置30m i n 后,以试剂空白作参比,用1cm 比色杯测定其在不同波长下的吸光度,做出吸收曲线。结果表明Al(III)-SAF-CTMAB配合物在559nm 处有最大吸收,故选择559n m 为测定波长[3]。1. 5. 2

Fe 3+

对样品测定的影响

茶叶在制备过程中一般需要用铁锅炒干,因而其大多含有一定量的Fe 3+

。有相关文献记载当样品中Fe 3+

含量为 Al3+含量的5倍以上将对Al 3+的测定产生干扰。在4个25ml 容量瓶中各加入2.00ml 铝标准液(含Al 3+ 2μg) ;再分别加入浓度为2μg/ml的 Fe3+溶液0.00、3.00、5.00、7.00ml(即Fe 3+含量分别为Al 3+的0、3、5、7倍) ;以空白作参比分别测定其吸光度,后三者与第一个未加Fe 3+的作比较,发现加Fe 3+的比没加Fe 3+的溶液的吸光度值要低。如表1所示。当Fe 3+的含量为Al 3+的3倍时,吸光度值已有微小变化,当达到5倍时吸光度值已有明显不同,7倍时变化更大。说明对于此测定方法,3倍于Al 3+含量的Fe 3+已对测定结果产生干扰。本实验采用加入1%抗坏血酸以掩蔽此干扰。1. 5. 3

标准工作曲线的绘制

表1 Fe 3+的干扰

Tabel 1 Interference from Fe3+

Fe 3+体积(ml)

A B S 三次测定值A B S 平均值0.000.2566~0.25750.25713.000.2472~0.25310.25035.000.1856~0.18830.18697.00

0.1350~0.1375

0.1365

分别取0.00~5.00ml(1.0μg/ml)铝标准使用液置于25ml 比色管中,依次加入氨-氯化铵缓冲溶液1. 00m l 、3%CTMAB 溶液3.00ml 、1×10-3mol/L SAF溶液0.50ml ,加水稀释至刻度,摇匀。静置30m i n 后,以试剂空白作参比,在559nm 处分别测定不同浓度的吸光度并绘制出工作曲线(见图1) [3]。

A

浓度(μg/ml)

图1 标准工作曲线Fig.1 Standard curve

根据测得的标准工作曲线得回归方程为C=0.2826A+0.0044,相关系数r=0.9992,说明在波长559nm 处对浓度在0~5μg/(25ml)范围内的铝标准溶液的吸光度进行测定,其吸光度与浓度有良好的线性关系,可按此标准工作曲线进行定量测定。1. 5. 4

方法精密度实验

为了评价所用方法的精密度,根据前面的测试条件,取5个不同浓度的样品,在测定波长下测定其吸光度,结果见表2。

表2 方法精密度

Table 2 Precise of the method

样品取样浓度九次测定值平均值标准偏差变异系数编号(μg/ml)(μg/ml)(μg/ml)(μg/ml)(%)10.0400.0336~0.03420.03380.0002200.6520.0800.0721~0.07260.07230.0001780.2530.1200.1102~0.11090.11060.0002420.2240.1600.1717~0.17190.17180.0000770.055

0.200

0.2061~0.2067

0.2065

0.000197

0.10

由表2可知,标准偏差小于0.000242,变动系数小于0. 65%,表明精密度较高。

1. 5. 5

稳定性实验

分别取三种茶叶样品提取液茉莉花茶5.00ml 、苦丁

表4 茶叶样品中Al 3+含量的测定结果Table 4 Contents of the Al3+ in teas

茶5.00ml 、红茶3.00ml 于三个25ml 比色管中,依次加入氨-氯化铵缓冲溶液1.00ml 、3% CTMAB 溶液3.00ml 、1×10-3mol/L SAF溶液0.50ml ,加水稀释至刻度,摇匀。静置30m i n 后,以试剂空白作参比进行时间扫描。结果表明,三种样品的提取液在2h 内都具有良好的稳定性。1. 5. 61. 5. 7

回收率的测定

几种茶中Al 含量的回收率实验

3+

样品名称莉花茶苦丁茶红茶

Al 3+的三次测定值(μg/g)

802.7~915.7717.9~730.01622.5~1811.5

平均值(mg/kg)

856.6722.41724.7

甲胺的存在下,在氨-氯化铵缓冲溶液(pH10)中,使铝与水杨基荧光酮发生显色反应。此法相对于前者有较高的灵敏度,故本实验采用此法进行测定。

由表1可以看出,针对本测定方法,3倍以上的Fe 3+

即可对Al 3+含量的测定产生干扰。故在对茶叶样品中的铝进行提取后,加入1ml 1%的抗坏血酸溶液掩蔽此干扰,以保证测定结果的准确性。

由图1可知,Al 3+在0~5μg/(25ml)范围内,其浓度与吸光度具有良好的线性关系;由表2~4可知,该测定方法的精密度、回收率都较好,说明该法测定结果可靠。

由表4可知,三种茶样中A l 3+的含量由高到低依次为红茶、茉莉花茶、苦丁茶。国家有相关规定,人体铝的暂定摄入量标准为7m g /k g 。虽然测定的三种茶叶中铝含量远远大于该标准,但因泡茶过程中铝的溶出量有20%损失且饮茶后人体对铝的吸收量占摄入量的0. 5%,故正常饮用此三种茶叶并不会威胁人体健康。

对于本实验测定的三种茶叶,有材料显示曾有人做过同名茶叶的铝含量测定,但与本实验所用显色剂不同。有文献记载,已有用本实验所用显色剂测定膨化食品中铝含量的研究,而对其用于茶叶中铝含量测定尚无记载。

参考文献:

[1][2][3]

张加玲, 刘桂英. 铝对人体的危害、铝的来源及测定方法研究进展[J]. 临床医药实践杂志, 2005, 14(1): 3-6.

韩兰英, 徐荷香, 汪英兰, 等. Al-CAS-CTMAB-OP显色反应的研究[J]. 上饶师范学院学报, 2004, 24(6): 61.

王爱月, 杨新玲, 李漫男. 分光光度法测定食品中微量铝-Al(III)-SAF-CTMAB 体系[J]. 郑州粮食学院学报, 1998, (3): 15-17.

取7个25ml 的比色管,从茉莉花茶样品提取液中吸取3.50、4.50、5.50ml 于三个比色管中;再向另三个比色管中加入相同体积的样品液,然后分别加入1ml Al标准使用液。向此7个比色管中依次加入氨-氯化铵缓冲溶液1.00ml 、3% CTMAB 溶液3.00ml 、1×10mol/L

-3

SAF 溶液0.50ml ,加水稀释至刻度,摇匀。静置30min 后,以试剂空白作参比,在559n m 处,在标准曲线项下测定其对应浓度。结果见表3。

表3 茉莉花茶回收率实验结果

Table 3 Recovery of determining jasmine tea with the method加标前(μg/ml)

0.06410.07670.0883

加标量(μg/ml)

0.0400.0400.040

实测值(μg/ml)

0.10160.11660.1278

回收率(%)

9410099

按此方法进行苦丁茶及红茶中Al 3+含量的回收率实验,其结果表明其回收率均在93%~103%之间表明准确性较高。1. 6

茶叶样品中Al 3+含量的测定

按照回收率实验的方法分别对茉莉花茶、苦丁茶、红茶三种样品的Al 3+提取液进行取样并测定。测定结果见表4。2

讨 论

目前,在测定食品中铝含量的分光光度法中以铬天青s 比色法最为常用。而本实验选择在溴化十六烷基三

中文核心期刊

百种中国杰出学术期刊


相关文章

  • 食品中铝的测定及管理现状
  • 食品中铝的测定及管理现状 作者:赵晓光 陈丽华 李威 来源:<北方经贸>2012年第07期 摘要:鉴于铝已被公认为是食品中的污染物,国家相关部门应在基于风险评估及考虑食品中铝本底含量的基础上,制定各类食品中铝的限量.食品生产企业 ...查看


  • 面制食品中铝测定方法研究进展
  • 摘要:综述了近十年来面制食品中铝测定方法的研究进展,包括样品前处理方法及检测方法.前处理方法主要有干法灰化.湿法灰化.高压消解.微波消解等.铝的测定方法主要有分光光度法.荧光光度法.石墨炉原子吸收光谱法.电感耦合等离子体发射光谱法.电感耦合 ...查看


  • 燃料油十六烷值检测标准
  • 燃料油十六烷值检测标准 十六烷值,衡量柴油的发火性能的高低,衡量柴油在发动机中发火性能和做功能力的指标. 青岛东标能源检测中心燃料油检测项目:外观.破乳性.粘度.密度.含硫量.闪点.水分.灰分.机械杂质.色度.凝点.酸度.馏程.金属元素含量 ...查看


  • 分子荧光光度法测定海水中痕量铝
  • 10海湖盐与化工 第33卷第3期 分子荧光光度法测定海水中痕量铝 张桂香 (天津科技大学海洋科学与工程学院, 天津 300450) 摘 要: Al 3+能同许多有机试剂形成会发出荧光的荧光络合物.8-羟基喹啉与Al 3+ 所形成的络合物被氯 ...查看


  • 食品中铝消解具体步骤
  • 食品中铝消解步骤(供参考) 1.试样预消解: 高脂肪.高蛋白.高淀粉等难消解的样本需冷消化后方能进行消解. 2.消解: 2.1微波消解: 称取试样(最好是干燥过的样品,可计算脱水率)0.2-0.5g (精确到0.001 g)于微波消解內罐中 ...查看


  • 新催化动力学光度法测定痕量铝
  • 第 "卷第 期 年 月分析试验室 ?; @ A2 6 2B 6 C@;@ 6D2 6E2 C F2 " 52 GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGG ...查看


  • 大学分析化学实验试题
  • 分析化学实验试题 一.单项选择 ( 在四个答案中,选一个正确的答案将其序号填在 ( ) 内,每小题 1 分,共 12 分 ) 1 .摩尔法的指示剂是( ). A. K 2Cr2O7 B. K2 CrO 4 C. Fe3+ D. SCN- 2 ...查看


  • 茶叶中重金属含量测定
  • 茶叶中重金属含量测定 摘要:本实验通过干灰化发和湿消化法对茶叶进行不同的前处理,利用石墨炉原子吸收法和ICP法两种不同的测定方法对茶叶中重金属含量进行分析测定,比较三种不同茶叶(元春茶,铁观音和毛尖)中的铅, 镁, 钙, 锰, 铁, 铜, ...查看


  • 试样中钒和铝含量的精确测定
  • 试样中钒和铝含量的精确测定 今年暑假是最忙碌的,我需要做很多事,所以实践的时间不是很充裕,内容也不是很特别,在去年的基础上进一步的进行练习和掌握.由于实践的机会较多,我和化验室的师傅们都很熟了,她们这次交给我更多的是工作经验,这也是我从学习 ...查看